1SDA068042R1 ABB Ekip G-LS/I 250A XT4 3-Pole Generator Protection Trip Unit

1SDA068042R1 ABB Ekip G-LS/I 250A XT4 3-Pole Generator Protection Trip Unit

ABB 1SDA068042R1 Ekip G-LS/I is a 250 A three-pole electronic generator protection trip unit for compatible SACE Tmax XT4 moulded case circuit breakers, providing long-time, short-time and instantaneous protection.

SKU: 1SDA068042R1MPN: 1SDA068042R1
Price
List Price £589.49 ex VAT
Your Price (ex VAT) Save 25%
£442.12 25% OFF
You save £147.37 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £442.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£442.12

Why Choose the ABB Ekip G-LS/I 250A XT4 3-Pole Trip Unit?

The ABB Ekip G-LS/I In=250A XT4 3p, order code 1SDA068042R1, is an electronic generator protection trip unit designed for use with ABB SACE Tmax XT4 moulded case circuit breakers. As part of the ABB Tmax XT range, it provides specialised protection characteristics for generators and electrical distribution networks where dependable overload and short-circuit protection is required.

The Ekip G-LS/I release is specifically designed for generator protection applications, where fault-current behaviour can differ significantly from conventional utility-fed distribution systems. Generator short-circuit current can decay rapidly, making a suitably low protection threshold important for detecting and interrupting faults effectively. The Ekip G-LS/I is engineered to address these operating conditions while providing electronic protection and flexible coordination.

With a rated current of 250 A and a three-pole configuration, the 1SDA068042R1 is designed for the ABB XT4 frame and provides long-time, short-time and instantaneous protection functions. It is supplied as a separate trip unit for combination with a compatible XT4 breaking part, allowing the protection release and breaking unit to be selected according to the requirements of the installation.

Key Advantages

  • Specialised electronic trip unit for generator protection.
  • 250 A rated current for ABB XT4 applications.
  • Three-pole configuration for three-phase electrical systems.
  • Ekip G-LS/I protection with long-time, short-time and instantaneous functions.
  • Designed with protection characteristics suitable for generator fault currents.
  • Suitable for distribution networks with long cables and relatively low end-of-line fault currents.
  • Designed for combination with compatible ABB SACE Tmax XT4 breaking parts.

Key Features

  • ABB SACE Tmax XT series.
  • Ekip G-LS/I electronic release.
  • 250 A rated current.
  • 3-pole configuration.
  • Designed for XT4 moulded case circuit breakers.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Electronic solid-state tripping technology.
  • Optimised protection characteristics for generator applications.
  • Suitable for AC electrical systems.
  • Separate trip unit for assembly with a compatible XT4 breaking part.

Electronic Protection for Generator Applications

Generator protection presents different requirements from conventional distribution protection because the available short-circuit current from a generator can decrease rapidly following a fault. The ABB Ekip G-LS/I range is designed to provide protection characteristics appropriate for these conditions, helping the circuit breaker detect and interrupt fault currents while protecting the generator and connected electrical system.

The Ekip G-LS/I is also suitable for distribution networks incorporating very long cables, where cable impedance can result in relatively low fault currents at the end of the circuit. Its electronic protection functions make the 1SDA068042R1 a specialised solution for applications requiring coordinated long-time, short-time and instantaneous protection with an ABB Tmax XT4 circuit breaker.

Typical Applications

  • Low-voltage generator protection systems.
  • Standby and emergency generator installations.
  • Industrial generator distribution boards.
  • Generator-fed switchboards and electrical panels.
  • Distribution networks with long cable runs.
  • Systems with relatively low end-of-line fault currents.
  • Industrial and commercial power-generation installations.
  • OEM switchgear incorporating ABB Tmax XT4 circuit breakers.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA068042R1
Product type Electronic circuit breaker trip unit
Application Generator protection
Compatible circuit breaker frame XT4
Rated current (In) 250 A
Number of poles 3
Trip unit Ekip G-LS/I
Release type Electronic / solid state
Protection functions Long-time, short-time and instantaneous
Current type AC
Installation type Loose / separate trip unit for compatible XT4 breaking part
Standard IEC 60947-2
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA068042R1 used for?

The ABB 1SDA068042R1 is an electronic generator protection trip unit designed for use with compatible three-pole ABB SACE Tmax XT4 moulded case circuit breakers.

What is the rated current of the ABB 1SDA068042R1?

The Ekip G-LS/I 1SDA068042R1 has a rated current of 250 A.

What protection functions does the Ekip G-LS/I provide?

The Ekip G-LS/I provides long-time overload, short-time short-circuit and instantaneous short-circuit protection functions designed for generator applications.

Which ABB circuit breaker is the 1SDA068042R1 designed for?

The 1SDA068042R1 is a three-pole trip unit designed for the ABB SACE Tmax XT4 moulded case circuit breaker platform.

Is the ABB 1SDA068042R1 a complete circuit breaker?

No. The 1SDA068042R1 is the Ekip G-LS/I electronic trip unit and is intended to be combined with a compatible ABB XT4 breaking part to form the required circuit breaker configuration.

Trusted ABB Protection for Generator Systems

ABB SACE Tmax XT protection solutions are designed for demanding low-voltage electrical systems, with specialised Ekip G-LS/I electronic releases providing protection characteristics suited to generators and distribution networks with challenging fault-current conditions.