1SDA068036R1 ABB Ekip M-LRIU In=160A XT4 3p Electronic Motor Protection Trip Unit

1SDA068036R1 ABB Ekip M-LRIU In=160A XT4 3p Electronic Motor Protection Trip Unit

ABB 1SDA068036R1 Ekip M-LRIU In=160A XT4 3p is a 160 A three-pole solid-state electronic motor-protection trip unit for compatible Tmax XT4 circuit breakers, providing overload, rotor, instantaneous short-circuit and phase-unbalance protection.

SKU: 1SDA068036R1MPN: 1SDA068036R1
Price
List Price £1,273.98 ex VAT
Your Price (ex VAT) Save 25%
£955.49 25% OFF
You save £318.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £955.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£955.49

Why Choose the ABB Ekip M-LRIU In=160A XT4 3p Electronic Trip Unit?

The ABB Ekip M-LRIU In=160A XT4 3p, order code 1SDA068036R1, is a three-pole solid-state electronic trip unit designed for advanced motor protection with ABB SACE Tmax XT4 moulded case circuit breakers. It is supplied as a loose protection release for combination with a compatible XT4 breaking part, allowing the protective and interruption components of the circuit breaker to be selected for the requirements of the installation.

Rated at 160 A, the Ekip M-LRIU is specifically designed for motor applications and provides L, R, I and U protection functions. These functions address motor overload, locked-rotor or rotor-jam conditions, instantaneous short-circuit faults and phase unbalance, providing a more comprehensive motor-protection solution than conventional overload and instantaneous-only releases.

The 1SDA068036R1 is intended for three-pole AC applications and is compatible with the ABB Tmax XT4 platform. Its electronic protection architecture provides adjustable protection characteristics for coordination with motor starting behaviour and the characteristics of the protected equipment, making it well suited to industrial motor feeders, machinery and motor control systems.

Key Advantages

  • Advanced electronic motor protection trip unit for ABB Tmax XT4 circuit breakers.
  • 160 A rated current for higher-current motor applications.
  • LRIU protection functions tailored to motor protection requirements.
  • Long-time overload protection helps protect motors against sustained overcurrent.
  • Rotor protection addresses locked-rotor and motor-jam conditions.
  • Instantaneous protection responds rapidly to severe short-circuit faults.
  • Phase-unbalance protection helps protect motors from damaging current imbalance.
  • Three-pole configuration for three-phase AC motor circuits.
  • Loose trip-unit format enables pairing with a compatible XT4 breaking part.

Key Features

  • ABB SACE Tmax XT4 compatible.
  • Three-pole configuration.
  • 160 A rated current.
  • Ekip M-LRIU electronic release.
  • L function: motor overload protection.
  • R function: locked-rotor / rotor-jam protection.
  • I function: instantaneous short-circuit protection.
  • U function: phase-unbalance protection.
  • Solid-state electronic protection technology.
  • Designed specifically for motor protection applications.
  • Suitable for combination with compatible ABB XT4 circuit-breaker breaking parts.

Advanced LRIU Electronic Motor Protection

Electric motors require protection characteristics that account for normal starting current as well as abnormal operating conditions. The ABB Ekip M-LRIU is engineered specifically for this purpose, combining overload protection with dedicated rotor and phase-unbalance functions alongside instantaneous short-circuit protection. This allows the protection system to distinguish between normal motor operating behaviour and conditions that can damage the motor or connected equipment.

The modular Tmax XT4 architecture allows the Ekip M-LRIU trip unit to be combined with a compatible XT4 breaking part selected according to the required short-circuit interruption level. This approach gives panel builders and engineers flexibility when configuring motor-protection MCCBs for industrial machinery, pumps, fans, compressors, conveyors and other three-phase motor-driven equipment.

Typical Applications

  • Three-phase industrial motor protection.
  • Motor control centres and motor feeder circuits.
  • Pumps, fans and compressor systems.
  • Conveyor and materials-handling equipment.
  • Industrial machinery and production equipment.
  • HVAC motor circuits.
  • Process automation systems.
  • OEM machinery and control panels.
  • ABB Tmax XT4 motor-protection circuit-breaker assemblies.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA068036R1
Product type Electronic motor-protection trip unit
Compatible circuit-breaker frame XT4
Application Motor protection
Number of poles 3
Rated current (In) 160 A
Release type Electronic
Trip unit family Ekip M-LRIU
Protection functions L, R, I and U
Long-time function (L) Motor overload protection
Rotor function (R) Locked-rotor / rotor-jam protection
Instantaneous function (I) Instantaneous short-circuit protection
Unbalance function (U) Phase-unbalance protection
Instantaneous short-circuit setting range 960–2,080 A
Configuration Loose trip unit
Suitable for ABB Tmax XT4 moulded case circuit breaker
Suitable for motor protection Yes
EAN / GTIN 8015644019365
Package gross weight 1.1 kg
Package dimensions (W × H × L) 110 × 100 × 150 mm
Country of origin Italy
HSN / customs classification 85389099
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA068036R1?

The ABB 1SDA068036R1 is an Ekip M-LRIU 160 A three-pole electronic motor-protection trip unit designed for use with compatible ABB SACE Tmax XT4 moulded case circuit-breaker breaking parts.

What current rating does the Ekip M-LRIU 1SDA068036R1 have?

The trip unit has a rated current of 160 A and is designed for three-pole AC motor-protection applications using the ABB Tmax XT4 platform.

What does LRIU mean on the ABB Ekip M trip unit?

The LRIU designation identifies its motor-protection functions: L for overload protection, R for locked-rotor or rotor-jam protection, I for instantaneous short-circuit protection and U for phase-unbalance protection.

What is the instantaneous short-circuit setting range?

The instantaneous short-circuit release setting range for the 160 A Ekip M-LRIU is 960–2,080 A, allowing the instantaneous threshold to be coordinated with motor starting and fault-current characteristics.

Is the ABB 1SDA068036R1 a complete circuit breaker?

No. The 1SDA068036R1 is a loose electronic trip unit and must be used in combination with an appropriate ABB XT4 breaking part to create the required motor-protection circuit-breaker assembly.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT motor-protection solutions are used by panel builders, machine manufacturers and industrial engineers to provide configurable electronic protection for critical three-phase motors and motor-driven equipment.