1SDA068035R1 ABB Ekip M-LRIU In=100A XT4 3p Electronic Motor Protection Trip Unit

1SDA068035R1 ABB Ekip M-LRIU In=100A XT4 3p Electronic Motor Protection Trip Unit

ABB 1SDA068035R1 Ekip M-LRIU is a 100 A three-pole solid-state electronic motor protection trip unit for compatible SACE Tmax XT4 circuit breakers, providing overload, rotor-lock, instantaneous short-circuit and phase-unbalance protection.

SKU: 1SDA068035R1MPN: 1SDA068035R1
Price
List Price £1,273.98 ex VAT
Your Price (ex VAT) Save 25%
£955.49 25% OFF
You save £318.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £955.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£955.49

Why Choose the ABB Ekip M-LRIU In=100A XT4 3p Trip Unit?

The ABB Ekip M-LRIU In=100A XT4 3p, order code 1SDA068035R1, is a three-pole electronic motor protection trip unit designed for use with compatible ABB SACE Tmax XT4 moulded case circuit breakers. Part of the ABB Tmax XT platform, it provides dedicated protection functions for three-phase motors and industrial motor circuits where accurate electronic protection and dependable coordination are required.

Rated at 100 A, the Ekip M-LRIU combines multiple motor-specific protection functions in a solid-state electronic release. Its LRIU functionality provides long-time overload protection, rotor-lock or stall protection, instantaneous short-circuit protection and phase-unbalance protection, helping protect motors against electrical conditions that can cause overheating, excessive mechanical stress or winding damage.

The trip unit is designed specifically for three-pole ABB SACE Tmax XT4 circuit breakers and is supplied as a protection release rather than a complete moulded case circuit breaker. It must be combined with a compatible XT4 breaking part, allowing the required short-circuit performance level to be selected separately for the installation.

Key Advantages

  • Advanced ABB Ekip electronic motor protection trip unit for Tmax XT4 circuit breakers.
  • 100 A rated current for three-phase motor protection applications.
  • LRIU protection functions address multiple motor fault conditions.
  • Electronic protection provides accurate and repeatable trip characteristics.
  • Dedicated rotor-lock protection helps protect motors against prolonged stalled-rotor conditions.
  • Phase-unbalance protection helps detect potentially damaging current imbalance.
  • Three-pole configuration specifically designed for three-phase motor circuits.
  • Combines with compatible ABB Tmax XT4 breaking parts to create a complete motor protection circuit breaker.

Key Features

  • ABB SACE Tmax XT4 compatible.
  • Ekip M-LRIU electronic motor protection trip unit.
  • 100 A rated current.
  • Three-pole configuration.
  • Designed specifically for motor protection.
  • Long-time overload protection.
  • Rotor-lock / stall protection.
  • Instantaneous short-circuit protection.
  • Phase-unbalance protection.
  • Solid-state electronic release technology.
  • Designed for use with compatible Tmax XT4 moulded case circuit-breaker breaking parts.
  • Allows the XT4 breaking part and protection release to be selected as a coordinated motor protection assembly.

Advanced Electronic Protection for Three-Phase Motors

Industrial motors can experience fault conditions beyond conventional short circuits, including sustained overloads, locked-rotor conditions and phase-current imbalance. The ABB Ekip M-LRIU combines dedicated electronic protection functions to detect these conditions and command the associated XT4 circuit breaker to trip before excessive electrical or thermal stress damages the motor or connected equipment.

The 100 A Ekip M-LRIU provides a flexible motor protection solution by combining overload, rotor-lock, instantaneous short-circuit and phase-unbalance functions within one electronic release. Because the trip unit is paired with a separately selected XT4 breaking part, designers can match the circuit breaker's interruption performance to the prospective fault level of the installation while retaining the required motor protection characteristics.

Typical Applications

  • Three-phase industrial motor protection.
  • Motor control centres.
  • Pumps and pumping systems.
  • Fans and industrial ventilation equipment.
  • Compressors and refrigeration machinery.
  • Conveyors and material-handling systems.
  • Industrial machinery and production lines.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA068035R1
Product type Electronic motor protection trip unit
Compatible circuit breaker ABB SACE Tmax XT4
Rated current 100 A
Number of poles 3
Trip unit family Ekip M
Trip unit designation Ekip M-LRIU
Release technology Solid-state electronic
Application Motor protection
Long-time overload protection L function
Rotor-lock / stall protection R function
Instantaneous short-circuit protection I function
Phase-unbalance protection U function
Circuit-breaker compatibility XT4 three-pole breaking parts
Breaking capacity Determined by the selected XT4 breaking part
Installation Combined with a compatible XT4 breaking part
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA068035R1?

The ABB 1SDA068035R1 is a 100 A three-pole Ekip M-LRIU electronic trip unit designed for motor protection with compatible ABB SACE Tmax XT4 moulded case circuit breakers.

Is the ABB 1SDA068035R1 a complete circuit breaker?

No. The 1SDA068035R1 is the electronic motor protection trip unit. It is designed to be combined with a compatible ABB Tmax XT4 breaking part to form a complete motor protection circuit breaker.

What protection functions does the Ekip M-LRIU provide?

The Ekip M-LRIU provides long-time overload protection, rotor-lock or stall protection, instantaneous short-circuit protection and phase-unbalance protection for three-phase motor circuits.

What is the rated current of the ABB Ekip M-LRIU 1SDA068035R1?

The electronic trip unit has a rated current of 100 A and is intended for compatible three-pole ABB SACE Tmax XT4 circuit breakers.

Which circuit breaker is the ABB 1SDA068035R1 designed for?

The trip unit is designed for compatible three-pole ABB SACE Tmax XT4 moulded case circuit-breaker breaking parts. The selected XT4 breaking part determines the final short-circuit interruption performance of the assembled circuit breaker.

Trusted ABB Motor Protection

ABB Ekip motor protection releases combine electronic precision with dedicated motor protection functions, providing a flexible solution for protecting three-phase motors when paired with compatible SACE Tmax XT moulded case circuit breakers.