1SDA067483R1 ABB TMA 200-2000 XT4 4p InN=100% Thermomagnetic Release

1SDA067483R1 ABB TMA 200-2000 XT4 4p InN=100% Thermomagnetic Release

ABB TMA 200-2000 XT4 4p InN=100% thermomagnetic release accessory designed for Tmax XT4 circuit breakers to provide reliable AC/DC overload and short-circuit protection.

SKU: 1SDA067483R1MPN: 1SDA067483R1
Price
List Price £611.18 ex VAT
Your Price (ex VAT) Save 25%
£458.39 25% OFF
You save £152.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £458.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£458.39

Why Choose the ABB TMA 200-2000 XT4 4p InN=100% Thermomagnetic Release?

The ABB TMA 200-2000 XT4 4p InN=100% is a reliable thermomagnetic trip unit designed for ABB SACE Tmax XT4 moulded case circuit breakers. As part of the advanced ABB Tmax XT accessory range, this four-pole release provides combined thermal overload and magnetic short-circuit protection for dependable low-voltage power distribution systems. :chatgpt-content-reference{index="0"}

Designed for industrial and commercial electrical installations, the TMA release enhances the protection capability of compatible XT4 circuit breakers by providing accurate response to overload conditions and high-current faults. The InN=100% configuration provides a fully rated neutral pole for four-pole distribution applications. :chatgpt-content-reference{index="1"}

With a rated current of 200 A, a four-pole configuration and an adjustable instantaneous magnetic protection range of 1000–2000 A, the ABB TMA 200-2000 XT4 4p InN=100% is suitable for AC/DC power distribution systems requiring dependable circuit protection. :chatgpt-content-reference{index="2"}

Key Advantages

  • Thermomagnetic protection solution for ABB Tmax XT4 moulded case circuit breakers.
  • Four-pole configuration with fully rated neutral protection for versatile distribution systems.
  • AC/DC compatibility for flexible low-voltage electrical applications.
  • Adjustable instantaneous magnetic protection from 1000 A to 2000 A for fault protection flexibility.
  • Provides dependable overload and short-circuit protection.
  • Designed for straightforward integration with ABB SACE Tmax XT4 circuit breakers.

Key Features

  • ABB Tmax XT thermomagnetic release.
  • TMA release technology.
  • 200 A rated current.
  • Four-pole (4P) design.
  • Fully rated neutral configuration: InN=100%.
  • Instantaneous magnetic protection adjustment: 1000–2000 A.
  • AC/DC current system compatibility.
  • Compatible with ABB Tmax XT4 moulded case circuit breakers.
  • Designed according to IEC 60947-2 requirements. :chatgpt-content-reference{index="3"}

Reliable Protection for Low-Voltage Distribution Systems

Thermomagnetic releases combine thermal protection against sustained overload currents with magnetic protection against short-circuit events. This allows circuit breakers to protect cables, electrical equipment and distribution networks from damaging overcurrent conditions.

The ABB TMA 200-2000 XT4 4p InN=100% provides engineers with a dependable protection solution for switchboards, industrial control panels and electrical distribution systems where a fully rated neutral is required.

Typical Applications

  • Industrial low-voltage distribution systems.
  • Commercial electrical switchboards.
  • Control panels and automation cabinets.
  • Cable and equipment protection installations.
  • AC and DC power distribution applications.
  • ABB Tmax XT4 moulded case circuit breaker assemblies.

Technical Specifications

Series SACE Tmax XT
Product type Thermomagnetic release accessory
Order code 1SDA067483R1
Compatible circuit breaker ABB Tmax XT4
Release type TMA thermomagnetic
Rated current (In) 200 A
Number of poles 4P
Neutral protection 100%
Current type AC/DC
Instantaneous magnetic protection range 1000–2000 A
Standards IEC 60947-2
Configuration type Loose or configurable accessory
Suitable for ABB SACE Tmax XT4 power distribution circuit breakers

Frequently Asked Questions

What is the ABB TMA 200-2000 XT4 4p InN=100% used for?

This thermomagnetic release is used with ABB Tmax XT4 circuit breakers to provide overload and short-circuit protection in low-voltage distribution systems.

Which circuit breaker is compatible with this release?

The ABB TMA 200-2000 XT4 4p InN=100% is designed for use with ABB SACE Tmax XT4 moulded case circuit breakers.

What is the rated current of this TMA release?

The release has a rated current of 200 A.

What is the magnetic protection adjustment range?

The instantaneous magnetic protection range is adjustable from 1000 A to 2000 A.

What does InN=100% mean on this ABB release?

The InN=100% designation indicates a fully rated neutral pole suitable for four-pole distribution systems.

Trusted by Industrial Electrical Engineers Worldwide

ABB Tmax XT thermomagnetic releases provide reliable circuit protection solutions for modern electrical distribution systems, helping engineers achieve safe, efficient and dependable installations.