1SDA067482R1 ABB TMA 160-1600 XT4 4-Pole InN=100% Thermomagnetic Trip Unit

1SDA067482R1 ABB TMA 160-1600 XT4 4-Pole InN=100% Thermomagnetic Trip Unit

ABB 1SDA067482R1 is a 160 A four-pole TMA thermomagnetic trip unit for compatible Tmax XT4 circuit breakers, featuring an adjustable 800–1600 A instantaneous short-circuit release and a fully rated 100% neutral.

SKU: 1SDA067482R1MPN: 1SDA067482R1
Price
List Price £611.18 ex VAT
Your Price (ex VAT) Save 25%
£458.39 25% OFF
You save £152.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £458.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£458.39

Why Choose the ABB TMA 160-1600 XT4 4p InN=100% Trip Unit?

The ABB TMA 160-1600 XT4 4p InN=100% is a thermomagnetic protection trip unit designed for compatible ABB Tmax XT4 moulded-case circuit breakers. Identified by ABB order code 1SDA067482R1, it combines thermal overload protection with adjustable instantaneous magnetic short-circuit protection for low-voltage power distribution applications.

This TMA release has a rated current of 160 A and is designed for 4-pole Tmax XT4 configurations. Its undelayed short-circuit release is adjustable from 800–1600 A, enabling the instantaneous magnetic protection threshold to be selected within the specified range for the protected circuit.

The InN=100% configuration provides a fully rated neutral, making the 1SDA067482R1 particularly suitable for four-pole distribution systems where the neutral requires protection at the same rated current as the phase conductors. The release is suitable for compatible AC and DC Tmax XT4 circuit-breaker applications.

Key Advantages

  • Genuine ABB Tmax XT4 thermomagnetic trip unit.
  • 160 A rated current for compatible XT4 circuit-breaker assemblies.
  • Adjustable 800–1600 A instantaneous short-circuit release range.
  • 4-pole configuration for distribution systems incorporating a neutral conductor.
  • InN=100% configuration with a fully rated neutral.
  • Combines thermal overload and magnetic short-circuit protection.
  • Suitable for compatible AC and DC circuits.

Key Features

  • ABB Tmax XT4 compatible protection release.
  • TMA thermomagnetic release.
  • 160 A rated current.
  • 800–1600 A adjustable undelayed short-circuit release.
  • 4-pole design.
  • 100% neutral rating.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against high short-circuit currents.

Adjustable Thermomagnetic Protection for Tmax XT4

Thermomagnetic releases combine two complementary protection functions. The thermal element responds to sustained overload currents that could cause excessive heating, while the magnetic element provides rapid operation under high short-circuit current conditions. This combination provides straightforward circuit protection without requiring an electronic trip unit.

The ABB TMA 160-1600 XT4 4p InN=100% combines a 160 A rated current with an adjustable 800–1600 A instantaneous short-circuit release range. Its four-pole configuration and fully rated neutral make it particularly useful for compatible low-voltage distribution systems where protection of the neutral conductor is required at 100% of phase rated current.

Typical Applications

  • Low-voltage electrical distribution boards.
  • Industrial switchboards and power distribution panels.
  • Commercial electrical installations.
  • Three-phase systems incorporating a fully rated neutral conductor.
  • Feeder and distribution circuit protection.
  • Industrial power systems requiring adjustable instantaneous protection.
  • Compatible ABB Tmax XT4 moulded-case circuit-breaker assemblies.

Technical Specifications

Series Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA067482R1
GTIN / EAN 8015644695323
Product type Thermomagnetic circuit-breaker trip unit
Release TMA
Compatible frame Tmax XT4
Rated current 160 A
Instantaneous short-circuit adjustment range 800–1600 A
Number of poles 4
Neutral protection InN=100%
Neutral rating Fully rated neutral
Current type AC / DC
Protection technology Thermomagnetic
Net weight 1.00 kg
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA067482R1?

The ABB 1SDA067482R1 is a TMA 160-1600 thermomagnetic trip unit designed for compatible four-pole ABB Tmax XT4 moulded-case circuit-breaker assemblies.

What is the rated current of the ABB TMA 160-1600 XT4 trip unit?

The trip unit has a rated current of 160 A.

What is the instantaneous short-circuit adjustment range?

The undelayed magnetic short-circuit release is adjustable from 800–1600 A.

What does InN=100% mean on the ABB 1SDA067482R1?

InN=100% identifies a fully rated neutral configuration, providing neutral protection at 100% of the phase rated current.

How many poles is the ABB 1SDA067482R1 designed for?

The 1SDA067482R1 is designed for a 4-pole Tmax XT4 circuit-breaker configuration.

Can the ABB TMA 160-1600 XT4 4p be used on AC and DC circuits?

Yes. The TMA 160-1600 XT4 4p release is suitable for compatible AC and DC circuit-breaker applications.

What protection does the TMA release provide?

The TMA release combines thermal overload protection with adjustable instantaneous magnetic short-circuit protection.

Is the ABB 1SDA067482R1 a complete circuit breaker?

No. The 1SDA067482R1 is a thermomagnetic protection trip unit designed for integration with compatible ABB Tmax XT4 circuit-breaker components.