1SDA067478R1 ABB TMA 200-2000 XT4 4P InN=50% Trip Unit

1SDA067478R1 ABB TMA 200-2000 XT4 4P InN=50% Trip Unit

ABB 1SDA067478R1 is a 200 A four-pole TMA thermomagnetic trip unit with 2000 A magnetic protection and 50% neutral protection for compatible Tmax XT4 circuit breakers.

SKU: 1SDA067478R1MPN: 1SDA067478R1
Price
List Price £611.18 ex VAT
Your Price (ex VAT) Save 25%
£458.39 25% OFF
You save £152.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £458.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£458.39

Why Choose the ABB 1SDA067478R1 TMA 200-2000 XT4 4P InN=50% Trip Unit?

The ABB 1SDA067478R1 is a TMA thermomagnetic trip unit designed for use with ABB Tmax XT4 moulded-case circuit breakers in low-voltage power distribution systems. Part of the ABB Tmax XT range, this four-pole protection unit provides thermal overload and magnetic short-circuit protection for installations requiring dependable circuit protection and selective coordination.

The TMA 200-2000 trip unit combines an adjustable thermal protection element with instantaneous magnetic protection, providing reliable protection against sustained overloads and high fault currents. It is intended for installation with a compatible XT4 breaking unit and is suitable for industrial switchboards, distribution panels and other electrical power distribution applications.

With a rated current of 200 A, magnetic protection up to 2000 A and a four-pole configuration, the 1SDA067478R1 is designed for ABB XT4 circuit breakers rated up to the 250 A frame size. The InN=50% configuration provides neutral-pole protection set at 50% of the phase conductor rated current.

Key Advantages

  • Reliable thermomagnetic protection for ABB Tmax XT4 circuit breakers.
  • 200 A rated current for low-voltage power distribution applications.
  • Magnetic protection rated up to 2000 A for short-circuit protection.
  • Four-pole design for three-phase systems with neutral protection.
  • Neutral protection set to 50% of rated current with the InN=50% configuration.
  • Designed specifically for use with compatible ABB Tmax XT4 breaking units.

Key Features

  • ABB Tmax XT TMA thermomagnetic trip unit.
  • 200 A nominal current rating.
  • 2000 A magnetic protection level.
  • 4-pole configuration.
  • InN=50% neutral protection configuration.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against high short-circuit currents.
  • Designed for power distribution protection with ABB XT4 circuit breakers.

Reliable Protection for Low-Voltage Distribution Systems

Thermomagnetic trip units combine two complementary protection methods. The thermal element responds to sustained overload currents that could overheat cables and connected equipment, while the magnetic element provides rapid operation when high short-circuit currents occur.

The ABB Tmax XT platform is designed for low-voltage distribution applications where compact dimensions, dependable protection and flexible system configuration are required. The 1SDA067478R1 enables a compatible XT4 circuit breaker to provide four-pole protection with reduced neutral protection at 50% of the phase-current setting.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Electrical switchboards and control panels.
  • Commercial and industrial power distribution systems.
  • Protection of feeders and distribution circuits.
  • Three-phase systems incorporating a neutral conductor.
  • OEM electrical equipment and machine power distribution.

Technical Specifications

Series Tmax XT
Product group Tmax XT 250 Range
Order code 1SDA067478R1
Product type Thermomagnetic circuit breaker trip unit
Compatible circuit breaker ABB Tmax XT4
Protection application Power distribution
Rated current 200 A
Magnetic protection 2000 A
Number of poles 4
Neutral protection 50% of rated current (InN=50%)
Trip technology Thermal-magnetic
XT4 frame rating up to 250 A
Installation Used with a compatible XT4 breaking unit

Frequently Asked Questions

What is the ABB 1SDA067478R1 used for?

The ABB 1SDA067478R1 is a thermomagnetic trip unit used with compatible ABB Tmax XT4 moulded-case circuit breakers to provide overload and short-circuit protection in low-voltage power distribution systems.

What is the rated current of the 1SDA067478R1?

The trip unit has a rated current of 200 A and is designated TMA 200-2000.

What does 200-2000 mean on this ABB TMA trip unit?

The designation identifies the 200 A rated current and 2000 A magnetic protection level of the thermomagnetic trip unit.

What does InN=50% mean?

InN=50% indicates that the neutral-pole protection is configured at 50% of the rated phase current.

Which circuit breaker is the 1SDA067478R1 designed for?

The trip unit is designed for use with a compatible ABB Tmax XT4 breaking unit in the Tmax XT 250 range.

Trusted ABB Circuit Protection

ABB Tmax XT circuit protection products are widely used in industrial and commercial electrical distribution systems where reliable overload and short-circuit protection, compact installation and flexible system design are required.