ABB 1SDA067473R1 TMA 63-630 XT4 4P is a 63 A four-pole thermomagnetic trip unit with thermal overload and adjustable 315–630 A magnetic short-circuit protection for compatible ABB SACE Tmax XT4 circuit-breakers.

SKU: 1SDA067473R1MPN: 1SDA067473R1
Price
List Price £611.18 ex VAT
Your Price (ex VAT) Save 25%
£458.39 25% OFF
You save £152.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £458.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£458.39

Why Choose the ABB TMA 63-630 XT4 4P Trip Unit?

The ABB 1SDA067473R1 is a TMA thermomagnetic trip unit designed for four-pole ABB SACE Tmax XT4 moulded-case circuit-breakers. Identified by ABB as TMA 63-630 XT4 4P, it combines thermal overload protection with adjustable instantaneous magnetic short-circuit protection for dependable low-voltage power distribution.

As part of the ABB SACE Tmax XT range, the TMA release uses proven thermomagnetic protection technology for AC and DC applications. The thermal element provides inverse-time protection against sustained overload conditions, while the magnetic element provides rapid operation during short-circuit faults, helping protect conductors, switchgear and connected electrical equipment.

With a rated current of 63 A and a four-pole configuration, the TMA 63-630 XT4 4P provides an adjustable instantaneous magnetic trip threshold of 315–630 A. This corresponds to approximately 5–10 × In, allowing the short-circuit protection characteristic to be matched to the requirements of compatible ABB Tmax XT4 power distribution applications.

Key Advantages

  • Genuine ABB TMA thermomagnetic trip unit for Tmax XT4 circuit-breakers.
  • 63 A rated current for low-voltage power distribution applications.
  • Combined thermal overload and magnetic short-circuit protection.
  • Adjustable instantaneous magnetic protection from 315–630 A.
  • Four-pole configuration for compatible four-pole distribution systems.
  • Suitable for AC and DC applications.

Key Features

  • ABB TMA thermomagnetic release.
  • 63 A rated current (In).
  • Thermal protection for sustained overload conditions.
  • Adjustable magnetic protection for short-circuit faults.
  • 315–630 A instantaneous magnetic trip setting (I3).
  • Magnetic protection adjustment of approximately 5–10 × In.
  • Four-pole configuration.
  • Suitable for AC/DC circuits.
  • Designed for power distribution applications.
  • Suitable for compatible ABB SACE Tmax XT4 circuit-breakers.
  • Part of the ABB SACE Tmax XT product family.

Reliable Thermomagnetic Circuit Protection

Thermomagnetic trip units combine two complementary protection mechanisms. The thermal element responds to sustained overload currents using an inverse-time characteristic, while the magnetic element responds rapidly to high short-circuit currents. This combination provides dependable circuit protection without requiring an electronic trip unit or external control power.

The ABB TMA release is suited to power distribution systems requiring adjustable short-circuit protection. When combined with the appropriate four-pole ABB Tmax XT4 breaking part, the 63 A trip unit provides overload and short-circuit protection for feeders, distribution circuits, machinery and other low-voltage electrical equipment.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical distribution systems.
  • Four-pole AC power distribution circuits.
  • Compatible DC distribution applications.
  • Machine and equipment distribution panels.
  • Industrial switchboards and control panels.

Technical Specifications

Product group T-Max XT 250 Range
Series SACE Tmax XT4
ABB order code 1SDA067473R1
EAN 8015644013653
Product type Thermomagnetic trip unit / circuit-breaker release
Release TMA
Release type Thermomagnetic
Rated current (In) 63 A
Instantaneous magnetic setting (I3) 315–630 A
Magnetic protection adjustment approximately 5–10 × In
Protection functions Thermal overload and magnetic short-circuit protection
Current type AC/DC
Number of poles 4
Application Power distribution
Suitable for ABB Tmax XT4
Product class SACE Tmax XT
Configuration type Loose or configurable
Standard IEC
Dimensions (W × H × D) 162 × 92 × 100 mm
Net weight 1 kg
Package gross weight 1.1 kg
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA067473R1 used for?

The ABB 1SDA067473R1 is a TMA thermomagnetic trip unit designed for compatible four-pole ABB Tmax XT4 circuit-breakers, providing thermal overload and adjustable magnetic short-circuit protection for power distribution applications.

What is the rated current of the ABB 1SDA067473R1?

The TMA 63-630 XT4 4P trip unit has a rated current of 63 A.

What protection does the TMA release provide?

The TMA release combines thermal overload protection with adjustable magnetic short-circuit protection, helping protect electrical circuits against sustained overloads and high fault currents.

What is the magnetic short-circuit setting range?

The instantaneous magnetic trip threshold is adjustable from 315–630 A, corresponding to approximately 5–10 × In for this 63 A trip unit.

Which ABB circuit-breaker is the 1SDA067473R1 designed for?

The trip unit is designed to be combined with a compatible ABB SACE Tmax XT4 four-pole breaking part for AC or DC power distribution applications.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit-breakers and TMA thermomagnetic releases provide dependable overload and short-circuit protection for industrial and commercial low-voltage distribution systems, switchboards and electrical equipment.