1SDA067365R1 ABB Ekip G-LS/I In=160A XT2 3p Electronic Trip Unit

1SDA067365R1 ABB Ekip G-LS/I In=160A XT2 3p Electronic Trip Unit

ABB 1SDA067365R1 Ekip G-LS/I In=160A XT2 3p is a 160 A three-pole electronic trip unit for compatible SACE Tmax XT2 circuit breakers, designed to provide adjustable overload and short-circuit protection for generator applications.

SKU: 1SDA067365R1MPN: 1SDA067365R1
Price
List Price £467.94 ex VAT
Your Price (ex VAT) Save 25%
£350.96 25% OFF
You save £116.99 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £350.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£350.96

Why Choose the ABB Ekip G-LS/I In=160A XT2 3p Electronic Trip Unit?

The ABB Ekip G-LS/I In=160A XT2 3p, order code 1SDA067365R1, is a three-pole electronic trip unit for generator protection designed for use with compatible ABB SACE Tmax XT2 moulded-case circuit breakers. As part of the ABB SACE Tmax XT range, it provides configurable electronic overload and short-circuit protection for low-voltage generator and AC distribution applications.

This Ekip G Dip LS/I release has a rated current of 160 A and provides long-time overload protection (L) together with configurable short-circuit protection. Its overload threshold is adjustable over approximately 0.4–1 × In, while short-circuit protection can be adjusted over approximately 1–10 × In, with time-delay capability supporting coordination with other protective devices.

Designed specifically for the XT2 frame size, the 1SDA067365R1 has a three-pole configuration for three-phase AC systems. ABB's Ekip G protection platform is intended for generator applications, where accurate electronic protection and flexible settings help accommodate generator fault-current characteristics while maintaining dependable protection of the connected electrical network.

Key Advantages

  • Genuine ABB Ekip G electronic trip unit for SACE Tmax XT2 circuit breakers.
  • 160 A rated current for generator and AC distribution applications.
  • LS/I electronic protection for overload and short-circuit conditions.
  • Adjustable 0.4–1 × In overload protection range.
  • Adjustable 1–10 × In short-circuit protection range.
  • Three-pole configuration for three-phase generator circuits.

Key Features

  • ABB SACE Tmax XT series.
  • XT2 frame compatibility.
  • Ekip G Dip LS/I electronic trip technology.
  • 160 A rated current.
  • Long-time (L) overload protection.
  • Short-time / instantaneous short-circuit protection.
  • Configurable protection with time-delay capability.
  • Designed specifically for generator protection applications.

Reliable Electronic Protection for Generator Circuits

Generator circuits have protection requirements that differ from conventional utility-fed distribution circuits because generators can supply comparatively limited fault currents. The ABB Ekip G platform is designed to address these characteristics through adjustable electronic protection, helping protect generating equipment and connected circuits against overload and short-circuit conditions.

The ABB Ekip G-LS/I In=160A XT2 3p is supplied as a configurable trip unit for combination with a compatible three-pole XT2 breaking part. Its adjustable protection thresholds and time-delay capability allow engineers to coordinate generator protection with downstream circuit breakers and other protective devices.

Typical Applications

  • Low-voltage generator protection systems.
  • Standby and emergency generator installations.
  • Industrial generating sets and power systems.
  • Generator distribution switchboards.
  • Three-phase AC generation and distribution networks.
  • ABB SACE Tmax XT2 generator protection circuit-breaker assemblies.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA067365R1
Product type Electronic trip unit
Trip unit type Ekip G Dip LS/I
Compatible frame XT2
Rated current 160 A
Protection characteristic LS/I
Overload adjustment range 0.4–1 × In
Short-circuit adjustment range 1–10 × In
Number of poles 3
Current type AC
Application Generator protection
Release technology Electronic
Applicable circuit-breaker standard IEC 60947-2
EAN 8015644012625
Net weight 1 kg
Package dimensions (W × H × D) 110 × 100 × 150 mm
Package gross weight 1.1 kg

Frequently Asked Questions

What is the ABB 1SDA067365R1 used for?

The ABB 1SDA067365R1 is a 160 A three-pole Ekip G electronic trip unit designed for generator protection with compatible ABB SACE Tmax XT2 circuit breakers.

What does LS/I mean on the ABB Ekip G trip unit?

LS/I identifies the unit's long-time overload and configurable short-circuit protection functions, providing protection characteristics suited to generator applications.

What is the rated current of the ABB 1SDA067365R1?

The Ekip G-LS/I trip unit has a rated current of 160 A.

What protection adjustment ranges does the Ekip G-LS/I provide?

The overload protection is adjustable over approximately 0.4–1 × In, while short-circuit protection can be adjusted over approximately 1–10 × In, with time-delay capability.

Which ABB circuit breaker frame is the 1SDA067365R1 designed for?

The trip unit is designed for the ABB SACE Tmax XT2 frame and must be combined with a compatible three-pole XT2 breaking part.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT generator protection solutions are widely used in industrial and commercial power systems where accurate electronic protection, flexible adjustment and dependable protection of low-voltage generating equipment are required.