1SDA067362R1 ABB Ekip G-LS/I In=25A XT2 3P Electronic Trip Unit

1SDA067362R1 ABB Ekip G-LS/I In=25A XT2 3P Electronic Trip Unit

ABB 1SDA067362R1 is a 25 A three-pole Ekip G-LS/I microprocessor electronic trip unit for ABB SACE Tmax XT2 circuit breakers with adjustable overload and short-circuit protection for generator applications.

SKU: 1SDA067362R1MPN: 1SDA067362R1
Price
List Price £436.35 ex VAT
Your Price (ex VAT) Save 25%
£327.26 25% OFF
You save £109.09 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £327.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£327.26

Why Choose the ABB 1SDA067362R1 Ekip G-LS/I Electronic Trip Unit?

The ABB 1SDA067362R1 is an Ekip G-LS/I three-pole electronic trip unit designed for ABB SACE Tmax XT2 moulded-case circuit breakers. Rated at 25 A, it provides electronic overload and short-circuit protection specifically suited to generator protection and low-voltage AC distribution applications.

The Ekip G-LS/I release provides long-time overload protection (L) together with short-time and instantaneous short-circuit protection (S/I). The overload setting is adjustable across 0.4–1 × In, corresponding to approximately 10–25 A for this 25 A version, while the short-circuit protection range extends across 1–10 × In.

Designed specifically for the ABB SACE Tmax XT2 platform, the 1SDA067362R1 uses microprocessor-based solid-state protection technology. Its protection characteristics are particularly useful for generator applications, where adjustable overload and short-circuit settings can help coordinate the circuit breaker with the operating characteristics of the generating set.

Key Advantages

  • Genuine ABB Ekip G-LS/I electronic trip unit for Tmax XT2.
  • 25 A rated current.
  • Specifically designed for generator protection applications.
  • Adjustable overload protection from approximately 10–25 A.
  • Adjustable short-circuit protection across 1–10 × In.
  • Long-time, short-time and instantaneous protection functions.
  • Microprocessor-based electronic protection technology.
  • Three-pole configuration for compatible ABB Tmax XT2 circuit breakers.

Key Features

  • ABB SACE Tmax XT electronic protection technology.
  • Ekip G-LS/I electronic release.
  • 25 A rated current (In).
  • L: long-time overload protection.
  • S: short-time short-circuit protection.
  • I: instantaneous short-circuit protection.
  • 0.4–1 × In overload adjustment range.
  • 1–10 × In short-circuit protection adjustment range.
  • 3-pole configuration.
  • Designed for AC applications.
  • Suitable for ABB SACE Tmax XT2.
  • Optimised for generator protection.
  • ABB order code 1SDA067362R1.
  • EAN 8015644012595.

Electronic Protection Designed for Generator Applications

Generator protection requires circuit-breaker characteristics that can accommodate the electrical behaviour and fault-current capability of generating sets. The ABB Ekip G-LS/I release provides adjustable long-time overload and short-circuit protection, allowing the protection settings to be coordinated with the generator and downstream electrical system.

For the 25 A 1SDA067362R1, the overload protection can be adjusted across 0.4–1 × In, corresponding to approximately 10–25 A, while the short-circuit protection range extends across 1–10 × In. This flexibility makes the release particularly suitable for compatible Tmax XT2 generator protection assemblies.

Typical Applications

  • ABB Tmax XT2 three-pole moulded-case circuit-breaker assemblies.
  • Generator and generating-set protection.
  • Standby and emergency power systems.
  • Industrial generator distribution panels.
  • Commercial backup power installations.
  • Low-voltage generator feeders.
  • AC circuits requiring adjustable electronic overload and short-circuit protection.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA067362R1
Product type Electronic circuit-breaker trip unit
Release type Ekip G-LS/I
Release technology Microprocessor / solid-state electronic
Suitable for Tmax XT2
Primary application Generator protection
Rated current (In) 25 A
Overload adjustment range 0.4–1 × In
Overload current range 10–25 A
Short-circuit protection range 1–10 × In
Protection functions L, S/I
Current type AC
Number of poles 3P
Product net weight 1 kg
Package dimensions (L × W × H) 150 × 110 × 100 mm
EAN 8015644012595
Minimum order quantity 1 piece
Product group T-Max XT 250 Range

Frequently Asked Questions

What is the ABB 1SDA067362R1 used for?

The ABB 1SDA067362R1 is a 25 A three-pole Ekip G-LS/I electronic trip unit designed for compatible ABB Tmax XT2 moulded-case circuit breakers and is particularly suited to generator protection applications.

What is the rated current of the ABB 1SDA067362R1?

The ABB Ekip G-LS/I 1SDA067362R1 has a rated current of 25 A.

What protection functions does the ABB Ekip G-LS/I provide?

The Ekip G-LS/I provides long-time overload protection (L) together with short-time and instantaneous short-circuit protection (S/I), with adjustable settings suited to generator protection applications.

What is the overload adjustment range of the ABB 1SDA067362R1?

The overload protection is adjustable across 0.4–1 × In. With a rated current of 25 A, this corresponds to an adjustment range of approximately 10–25 A.

Which circuit breaker is the ABB 1SDA067362R1 designed for?

The 1SDA067362R1 is designed for compatible ABB SACE Tmax XT2 moulded-case circuit-breaker breaking parts and is configured as a three-pole AC electronic release.

Trusted ABB Generator Circuit Protection

ABB SACE Tmax XT Ekip G electronic trip units provide adjustable electronic protection for compatible generator circuit-breaker assemblies, supporting coordinated overload and short-circuit protection in professional standby, generation and power distribution systems.