1SDA067345R1 ABB Ekip LSI In=160A XT2 4p InN=100% Electronic Trip Unit

1SDA067345R1 ABB Ekip LSI In=160A XT2 4p InN=100% Electronic Trip Unit

ABB 1SDA067345R1 Ekip LSI In=160A XT2 4p InN=100% is a 160 A four-pole electronic trip unit for compatible SACE Tmax XT2 circuit breakers with LSI protection and a fully rated neutral.

SKU: 1SDA067345R1MPN: 1SDA067345R1
Price
List Price £1,261.78 ex VAT
Your Price (ex VAT) Save 25%
£946.34 25% OFF
You save £315.45 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £946.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£946.34

Why Choose the ABB Ekip LSI In=160A XT2 4p InN=100% Electronic Trip Unit?

The ABB Ekip LSI In=160A XT2 4p InN=100%, order code 1SDA067345R1, is a four-pole electronic trip unit designed for compatible ABB SACE Tmax XT2 moulded-case circuit breakers. As part of the ABB SACE Tmax XT range, it provides accurate electronic overload and short-circuit protection for low-voltage AC power distribution systems.

This Ekip LSI release has a rated current of 160 A and incorporates long-time (L), short-time (S) and instantaneous (I) protection functions. These functions provide protection against sustained overloads, delayed short-circuit conditions and high-level short circuits, helping engineers achieve effective protection coordination within industrial and commercial electrical networks.

The four-pole configuration features a 100% rated neutral (InN=100%), making the neutral pole fully rated relative to the phase current. Designed specifically for the XT2 frame size, the 1SDA067345R1 is suitable for systems where full neutral-current capability and configurable electronic protection are required.

Key Advantages

  • Genuine ABB Ekip electronic trip unit for SACE Tmax XT2 circuit breakers.
  • 160 A rated current for industrial and commercial power distribution.
  • LSI protection functions for overload and short-circuit protection.
  • Four-pole configuration for compatible four-pole XT2 assemblies.
  • 100% rated neutral (InN=100%) for full neutral-current capability.
  • Electronic protection technology supports accurate and coordinated circuit protection.

Key Features

  • ABB SACE Tmax XT series.
  • XT2 frame compatibility.
  • Ekip Dip LSI electronic trip technology.
  • 160 A rated current.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Four-pole construction with fully rated neutral.

Reliable Electronic Protection with a Fully Rated Neutral

Electronic trip units continuously evaluate circuit current and initiate circuit-breaker operation when configured protection thresholds are exceeded. The Ekip LSI functions separately address overload, delayed short-circuit and instantaneous short-circuit conditions, supporting selective and coordinated protection throughout low-voltage distribution networks.

The ABB Ekip LSI In=160A XT2 4p InN=100% combines these electronic protection functions with a fully rated neutral. This makes it particularly useful in four-wire distribution systems where neutral current can be significant and where the neutral conductor requires the same current rating as the phase conductors.

Typical Applications

  • Industrial low-voltage distribution systems.
  • Four-wire three-phase electrical networks.
  • Electrical switchboards and distribution panels.
  • Commercial building power distribution.
  • Infrastructure and utility installations.
  • ABB SACE Tmax XT2 four-pole moulded-case circuit-breaker assemblies.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA067345R1
Product type Electronic trip unit
Trip unit type Ekip Dip LSI
Compatible frame XT2
Rated current 160 A
Protection functions L, S, I
Long-time protection Overload protection
Short-time protection Short-circuit protection
Instantaneous protection Short-circuit protection
Number of poles 4
Neutral rating 100% (InN=100%)
Neutral current rating 160 A
Application AC power distribution
Compatible system voltage Up to 690 V AC
Applicable circuit-breaker standard IEC 60947-2
Release technology Solid-state electronic

Frequently Asked Questions

What is the ABB 1SDA067345R1 used for?

The ABB 1SDA067345R1 is a 160 A four-pole Ekip LSI electronic trip unit designed for compatible ABB SACE Tmax XT2 circuit breakers used in low-voltage AC power distribution.

What does LSI mean on the ABB Ekip trip unit?

LSI denotes long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I).

What does InN=100% mean on the ABB 1SDA067345R1?

InN=100% means the neutral is fully rated, with its rated current equal to 100% of the phase rated current, which is 160 A for this trip unit.

How many poles does the ABB 1SDA067345R1 have?

The 1SDA067345R1 is a four-pole electronic trip unit designed for compatible four-pole ABB SACE Tmax XT2 circuit-breaker assemblies.

Which ABB circuit breaker frame is the 1SDA067345R1 designed for?

The trip unit is designed for the ABB SACE Tmax XT2 frame and is used with compatible four-pole XT2 breaking units.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT electronic protection solutions are widely used in industrial and commercial electrical installations where accurate overload protection, coordinated short-circuit protection and dependable low-voltage power distribution are required.