1SDA067342R1 ABB Ekip LSI In=63A XT2 4p Electronic Trip Unit

1SDA067342R1 ABB Ekip LSI In=63A XT2 4p Electronic Trip Unit

ABB 1SDA067342R1 Ekip LSI In=63A XT2 4p is a 63 A four-pole electronic trip unit providing long-time, short-time and instantaneous protection for compatible ABB Tmax XT2 circuit breakers.

SKU: 1SDA067342R1MPN: 1SDA067342R1
Price
List Price £1,135.61 ex VAT
Your Price (ex VAT) Save 25%
£851.71 25% OFF
You save £283.90 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £851.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£851.71

Why Choose the ABB 1SDA067342R1 Ekip LSI In=63A XT2 4p Trip Unit?

The ABB 1SDA067342R1 is a four-pole Ekip LSI electronic trip unit designed for use with ABB SACE Tmax XT2 moulded-case circuit breakers in AC power distribution applications. Rated at 63 A, it provides electronic protection functions for long-time overload, short-time short-circuit and instantaneous short-circuit conditions.

As part of the ABB Tmax XT circuit breaker system, the Ekip LSI release is designed to provide dependable and configurable protection for low-voltage electrical distribution networks. Electronic protection technology enables accurate circuit monitoring and coordinated protection while supporting the compact architecture of the Tmax XT2 platform.

The 1SDA067342R1 is a four-pole AC electronic release with a rated current of 63 A. It is supplied as a loose or configurable accessory for association with an ABB XT2 circuit breaker and is intended for power distribution installations requiring LSI protection functionality.

Key Advantages

  • Electronic LSI protection for power distribution circuits.
  • 63 A rated current for compatible ABB Tmax XT2 circuit breakers.
  • Four-pole configuration for multi-pole AC distribution applications.
  • Long-time protection helps protect circuits against sustained overload conditions.
  • Short-time and instantaneous protection provide effective response to short-circuit faults.
  • Designed specifically for integration with the ABB SACE Tmax XT2 platform.

Key Features

  • ABB Ekip LSI electronic trip unit.
  • 63 A rated current (In).
  • Four-pole construction.
  • Suitable for AC power distribution applications.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Designed for ABB Tmax XT2 circuit breakers.

Reliable Electronic Protection for Power Distribution

Electronic trip units such as the ABB Ekip LSI continuously support circuit protection by responding to abnormal current conditions according to their configured protection functions. Long-time protection addresses sustained overloads, while short-time and instantaneous functions provide protection against higher-level short-circuit currents.

The Ekip LSI platform is designed to work as part of the ABB Tmax XT circuit breaker system. Its electronic protection functions make it suitable for industrial and commercial distribution systems where dependable overload and short-circuit protection is required within a compact moulded-case circuit breaker installation.

Typical Applications

  • Low-voltage electrical distribution panels.
  • Industrial power distribution systems.
  • Commercial electrical installations.
  • Machine and equipment distribution boards.
  • Motor and process power distribution circuits.
  • ABB Tmax XT2 moulded-case circuit breaker installations.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA067342R1
Product type Electronic circuit breaker trip unit
Release Ekip LSI
Release type EL electronic release
Rated current (In) 63 A
Current type AC
Number of poles 4
Suitable for ABB Tmax XT2
Circuit breaker application Power distribution
Configuration type Loose or configurable
Protection functions Long-time, short-time and instantaneous (LSI)
Reference standard IEC
Product net weight 1 kg
EAN 8015644012397

Frequently Asked Questions

What is the ABB 1SDA067342R1 used for?

The ABB 1SDA067342R1 is an Ekip LSI electronic trip unit used with compatible ABB Tmax XT2 circuit breakers to provide overload and short-circuit protection in AC power distribution systems.

What is the rated current of this Ekip LSI trip unit?

The trip unit has a rated current of 63 A.

What protection functions does the Ekip LSI provide?

The Ekip LSI provides long-time (L), short-time (S) and instantaneous (I) protection functions for overload and short-circuit conditions.

How many poles does the ABB 1SDA067342R1 have?

The 1SDA067342R1 is a four-pole electronic trip unit designed for AC applications.

Which circuit breaker is the 1SDA067342R1 designed for?

The trip unit is designed for use with compatible ABB SACE Tmax XT2 moulded-case circuit breakers used for power distribution.

Trusted Protection from ABB

ABB SACE Tmax XT circuit breaker systems and Ekip electronic trip units are widely used in industrial and commercial power distribution installations to provide dependable, configurable protection for low-voltage electrical networks.