1SDA067279R1 ABB TMG 100-300 XT2 4p Thermomagnetic Trip Unit

1SDA067279R1 ABB TMG 100-300 XT2 4p Thermomagnetic Trip Unit

ABB 1SDA067279R1 is a four-pole TMG thermomagnetic trip unit for SACE Tmax XT2 circuit breakers with a 100 A rated current and 300 A magnetic short-circuit protection threshold for generator applications.

SKU: 1SDA067279R1MPN: 1SDA067279R1
Price
List Price £287.48 ex VAT
Your Price (ex VAT) Save 25%
£215.61 25% OFF
You save £71.87 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £215.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£215.61

Why Choose the ABB 1SDA067279R1 TMG Trip Unit?

The ABB 1SDA067279R1 is a four-pole TMG thermomagnetic trip unit designed for ABB SACE Tmax XT2 moulded-case circuit breakers. As part of the ABB Tmax XT protection range, it provides thermal overload and magnetic short-circuit protection for generator and low-voltage power distribution applications.

This TMG release has a 100 A rated current and a 300 A magnetic short-circuit protection threshold. The TMG protection characteristic is designed specifically for generator applications, where appropriate overload and short-circuit protection is required while accommodating the operating characteristics of generating equipment.

Designed specifically for the four-pole Tmax XT2 frame, the 1SDA067279R1 provides protection across a four-pole circuit and is suitable for AC and DC applications. Its dedicated Tmax XT2 compatibility makes it a dependable choice for generator distribution panels, switchboards and industrial electrical systems.

Key Advantages

  • Genuine ABB SACE Tmax XT2 TMG thermomagnetic trip unit.
  • 100 A rated current for circuit protection.
  • 300 A magnetic short-circuit protection threshold.
  • TMG protection characteristic designed for generator applications.
  • Combines thermal overload and magnetic short-circuit protection.
  • Designed for four-pole ABB SACE Tmax XT2 circuit breakers.
  • Suitable for AC and DC applications.

Key Features

  • ABB SACE Tmax XT protection range.
  • TMG thermomagnetic generator protection release.
  • 100 A rated current.
  • 300 A magnetic protection threshold.
  • Four-pole configuration.
  • Compatible with the ABB Tmax XT2 frame.
  • Provides overload and short-circuit protection.
  • Suitable for generator and general low-voltage distribution applications.

Reliable Generator Protection for Tmax XT2 Circuit Breakers

TMG thermomagnetic releases are intended for applications where generator protection characteristics are required. The thermal element protects against sustained overload conditions, while the magnetic element responds to short-circuit currents, helping protect generators, conductors and connected distribution equipment.

The ABB 1SDA067279R1 is engineered specifically for the Tmax XT2 platform. Its 100 A current rating, 300 A magnetic threshold and four-pole configuration make it suitable for generator distribution systems and other compatible installations requiring reliable thermomagnetic circuit protection.

Typical Applications

  • Generator protection and distribution systems.
  • ABB Tmax XT2 moulded-case circuit breaker assemblies.
  • Industrial low-voltage distribution systems.
  • Four-pole electrical distribution circuits.
  • Generator switchboards and control panels.
  • AC and DC overload and short-circuit protection.

Technical Specifications

Series SACE Tmax XT
Model / order code 1SDA067279R1
Product type Thermomagnetic trip unit
Trip unit TMG
Suitable breaker Tmax XT2
Rated current 100 A
Magnetic protection threshold 300 A
Number of poles 4
Current type AC / DC
Protection application Generator protection
Standard IEC 60947-2
Net weight 1.1 kg
Country of origin Italy
EAN 8015644011826

Frequently Asked Questions

What is the ABB 1SDA067279R1 used for?

It is a TMG thermomagnetic trip unit for four-pole ABB SACE Tmax XT2 circuit breakers, designed particularly for generator protection and low-voltage distribution applications.

What is the rated current of this trip unit?

The ABB 1SDA067279R1 has a 100 A rated current.

What is the magnetic protection threshold?

The TMG release has a 300 A magnetic short-circuit protection threshold.

How many poles does the ABB 1SDA067279R1 have?

The trip unit has a four-pole configuration for use with compatible four-pole Tmax XT2 circuit breaker assemblies.

Is the ABB 1SDA067279R1 suitable for generator protection?

Yes. The TMG thermomagnetic release is designed for generator protection applications and provides overload and short-circuit protection when installed with a compatible Tmax XT2 breaker assembly.

Trusted ABB Generator Protection

ABB SACE Tmax XT TMG thermomagnetic releases provide dedicated generator protection characteristics in a compact circuit breaker platform, supporting dependable overload and short-circuit protection in industrial and commercial power systems.