ABB 1SDA067256R1 is a TMA 125-1250 thermomagnetic trip unit for Tmax XT2 4-pole circuit-breaker assemblies, rated at 125 A with 1250 A magnetic protection and 50% neutral protection.
£220.02
The ABB TMA 125-1250 XT2 4p InN=50% is a thermomagnetic protection trip unit designed for compatible ABB Tmax XT2 moulded-case circuit breakers. Identified by ABB order code 1SDA067256R1, it forms part of the ABB Tmax XT protection system for dependable overload and short-circuit protection in low-voltage electrical distribution applications.
This TMA trip unit is configured for a 125 A rated current with a 1250 A magnetic protection level and is intended for 4-pole XT2 configurations. Its thermomagnetic operating principle provides thermal protection against sustained overload conditions together with magnetic protection for high-current short circuits.
The InN=50% configuration provides neutral-pole protection set at 50% of the phase rated current, making the unit suitable for four-pole distribution systems where controlled neutral protection is required. It is designed to be combined with the appropriate ABB Tmax XT2 breaking part to create a complete circuit-breaker assembly.
Thermomagnetic trip units combine two complementary protection principles. The thermal element responds to sustained overload currents that can overheat conductors and connected equipment, while the magnetic element reacts rapidly to high fault currents associated with short-circuit conditions.
The ABB TMA 125-1250 XT2 4p InN=50% is designed as a protection component for a compatible Tmax XT2 circuit breaker. When combined with the appropriate breaking part, it provides a coordinated four-pole protection solution for low-voltage power distribution systems, including defined protection of the neutral conductor.
| Series | Tmax XT |
|---|---|
| Product group | T-Max XT 250 Range |
| ABB order code | 1SDA067256R1 |
| Product type | Thermomagnetic trip unit |
| Compatible frame | Tmax XT2 |
| Rated current | 125 A |
| Magnetic protection level | 1250 A |
| Number of poles | 4 |
| Neutral protection | 50% of rated phase current |
| Protection technology | Thermal-magnetic |
The ABB 1SDA067256R1 is a TMA 125-1250 thermomagnetic trip unit for compatible Tmax XT2 4-pole moulded-case circuit-breaker assemblies.
The trip unit has a rated current of 125 A.
The designation identifies the 125 A rated current and 1250 A magnetic protection level of the thermomagnetic trip unit.
InN=50% indicates that the neutral-pole protection is configured at 50% of the rated phase current.
No. It is a protection trip unit intended to be used together with the appropriate ABB Tmax XT2 breaking part to form a complete circuit-breaker assembly.
The ABB TMA 125-1250 XT2 InN=50% is designed for a 4-pole configuration.