1SDA067251R1 ABB TMA 40-400 XT2 4-Pole Thermomagnetic Trip Unit

1SDA067251R1 ABB TMA 40-400 XT2 4-Pole Thermomagnetic Trip Unit

ABB 1SDA067251R1 is a 40 A TMA thermomagnetic trip unit with adjustable 28–40 A thermal protection and 200–400 A magnetic protection for compatible four-pole ABB SACE Tmax XT2 moulded-case circuit breakers.

SKU: 1SDA067251R1MPN: 1SDA067251R1
Price
List Price £281.75 ex VAT
Your Price (ex VAT) Save 25%
£211.31 25% OFF
You save £70.44 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £211.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£211.31

Why Choose the ABB 1SDA067251R1 TMA Thermomagnetic Trip Unit?

The ABB 1SDA067251R1 is a genuine TMA thermomagnetic trip unit designed for compatible ABB SACE Tmax XT2 four-pole moulded-case circuit breakers. Identified by ABB as TMA 40-400 XT2 4p, it combines adjustable thermal overload protection with magnetic short-circuit protection for low-voltage electrical distribution applications.

The trip unit has a 40 A rated current and a magnetic protection range of 200–400 A. Its thermal protection can be adjusted to suit the protected circuit within the permitted setting range, while the magnetic element provides rapid operation when a sufficiently high short-circuit current occurs.

As part of the ABB SACE Tmax XT protection platform, the 1SDA067251R1 is specifically intended for the XT2 frame in a four-pole configuration. It provides a coordinated ABB solution for overload and short-circuit protection in compatible commercial, industrial and infrastructure power distribution assemblies.

Key Advantages

  • Genuine ABB TMA thermomagnetic trip unit for the SACE Tmax XT range.
  • Designed specifically for compatible XT2 four-pole circuit breakers.
  • 40 A rated current with adjustable thermal overload protection.
  • Provides 200–400 A magnetic short-circuit protection.
  • Combines overload and short-circuit protection in a compact mechanical trip unit.
  • Purpose-designed for integration with ABB low-voltage distribution equipment.

Key Features

  • ABB SACE Tmax XT TMA trip unit.
  • XT2 frame compatibility.
  • Designed for 4-pole configurations.
  • Rated current: 40 A.
  • Thermal setting range: 28–40 A.
  • Magnetic protection range: 200–400 A.
  • Thermal protection for sustained overload conditions.
  • Magnetic protection for high short-circuit currents.

Adjustable Thermomagnetic Protection for ABB Tmax XT2

A thermomagnetic trip unit combines two complementary overcurrent protection principles. The thermal element responds to sustained overloads and provides a time-dependent response, while the magnetic element responds rapidly to high fault currents to provide short-circuit protection.

The ABB 1SDA067251R1 provides a 28–40 A adjustable thermal setting range together with a 200–400 A magnetic protection range. This allows the TMA trip unit to be coordinated with compatible XT2 four-pole circuit breaker applications where adjustable conventional thermomagnetic protection is required.

Typical Applications

  • ABB SACE Tmax XT2 four-pole circuit breaker assemblies.
  • Low-voltage distribution boards and switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Feeder and branch circuit overload protection.
  • Circuits requiring adjustable thermal and magnetic overcurrent protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Model / order code 1SDA067251R1
Extended product type TMA 40-400 XT2 4p
Product type Thermomagnetic trip unit
Trip unit type TMA
Compatible frame size XT2
Number of poles 4
Rated current 40 A
Thermal setting range 28–40 A
Magnetic protection range 200–400 A
Protection technology Thermal-magnetic
Overload protection Adjustable thermal
Short-circuit protection Magnetic
Compatible circuit breaker type Moulded-case circuit breaker
Application Low-voltage circuit protection
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA067251R1?

The ABB 1SDA067251R1 is a TMA thermomagnetic trip unit designed for compatible four-pole ABB SACE Tmax XT2 moulded-case circuit breakers.

What is the rated current of the ABB 1SDA067251R1?

The ABB 1SDA067251R1 has a rated current of 40 A, with an adjustable thermal setting range of 28–40 A.

What does 40-400 mean in TMA 40-400?

The 40 A value identifies the rated current of the trip unit, while the magnetic short-circuit protection is adjustable across a 200–400 A range.

Which ABB circuit breaker frame is the 1SDA067251R1 designed for?

The ABB 1SDA067251R1 is designed for compatible SACE Tmax XT2 moulded-case circuit breakers in a four-pole configuration.

What protection does the ABB TMA trip unit provide?

The TMA trip unit provides adjustable thermal protection against sustained overloads together with magnetic protection against short-circuit currents, enabling the associated circuit breaker to respond to both types of overcurrent condition.

Trusted ABB Tmax XT Circuit Protection

ABB SACE Tmax XT thermomagnetic protection devices are engineered as part of a coordinated moulded-case circuit breaker platform, providing dependable overload and short-circuit protection for professional low-voltage distribution systems.