1SDA067226R1 ABB TMD 16-300 XT2 3-Pole Thermomagnetic Trip Unit

1SDA067226R1 ABB TMD 16-300 XT2 3-Pole Thermomagnetic Trip Unit

ABB 1SDA067226R1 is a 16 A TMD thermomagnetic trip unit with a 300 A magnetic protection setting for compatible three-pole ABB SACE Tmax XT2 moulded-case circuit breakers.

SKU: 1SDA067226R1MPN: 1SDA067226R1
Price
List Price £230.01 ex VAT
Your Price (ex VAT) Save 25%
£172.51 25% OFF
You save £57.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £172.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£172.51

Why Choose the ABB 1SDA067226R1 TMD Thermomagnetic Trip Unit?

The ABB 1SDA067226R1 is a genuine TMD thermomagnetic trip unit designed for compatible ABB SACE Tmax XT2 three-pole moulded-case circuit breakers. Identified by ABB as TMD 16-300 XT2 3p, it combines thermal overload protection with magnetic short-circuit protection for low-voltage electrical distribution applications.

The trip unit has a 16 A rated current and an instantaneous magnetic protection setting of 300 A. The thermal element responds to sustained overload conditions, while the magnetic element provides rapid operation when a sufficiently high short-circuit current occurs.

As part of the ABB SACE Tmax XT protection system, the 1SDA067226R1 is specifically intended for the XT2 frame in a three-pole configuration. It provides a coordinated ABB protection solution for compatible circuit breaker assemblies used in commercial, industrial and infrastructure power distribution systems.

Key Advantages

  • Genuine ABB TMD thermomagnetic trip unit for the SACE Tmax XT range.
  • Designed specifically for compatible XT2 three-pole circuit breakers.
  • 16 A thermal protection rating for overload protection.
  • 300 A magnetic trip threshold for short-circuit protection.
  • Combines thermal and magnetic protection functions in a coordinated trip unit.
  • Purpose-designed for integration with ABB low-voltage distribution equipment.

Key Features

  • ABB SACE Tmax XT TMD trip unit.
  • XT2 frame compatibility.
  • Designed for 3-pole configurations.
  • Rated current: 16 A.
  • Magnetic protection setting: 300 A.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against high short-circuit currents.
  • Mechanical thermomagnetic protection without dependence on an electronic trip unit.

Thermomagnetic Protection for ABB Tmax XT2

A thermomagnetic trip unit uses two complementary protection principles. The thermal element responds to prolonged overcurrent conditions and provides overload protection with a time-dependent response, while the magnetic element reacts rapidly when current rises to the short-circuit protection threshold.

For the ABB 1SDA067226R1, the TMD designation combines a 16 A thermal current rating with a 300 A magnetic protection setting. This makes the unit suitable for compatible XT2 three-pole circuit breaker assemblies where conventional thermal-magnetic protection is required.

Typical Applications

  • ABB SACE Tmax XT2 three-pole circuit breaker assemblies.
  • Low-voltage distribution boards and switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Feeder and branch circuit overload protection.
  • Circuits requiring thermal overload and magnetic short-circuit protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Model / order code 1SDA067226R1
Extended product type TMD 16-300 XT2 3p
Product type Thermomagnetic trip unit
Trip unit type TMD
Compatible frame size XT2
Number of poles 3
Rated current 16 A
Magnetic protection setting 300 A
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic instantaneous
Compatible circuit breaker type Moulded-case circuit breaker
Application Low-voltage circuit protection

Frequently Asked Questions

What is the ABB 1SDA067226R1?

The ABB 1SDA067226R1 is a TMD thermomagnetic trip unit designed for compatible three-pole ABB SACE Tmax XT2 moulded-case circuit breakers.

What is the rated current of the ABB 1SDA067226R1?

The ABB 1SDA067226R1 has a rated current of 16 A.

What does 300 mean in TMD 16-300?

The 300 A value identifies the magnetic short-circuit protection setting, while 16 A identifies the rated current of the thermal protection element.

Which ABB circuit breaker frame is the 1SDA067226R1 designed for?

The ABB 1SDA067226R1 is designed for compatible SACE Tmax XT2 moulded-case circuit breakers in a three-pole configuration.

What protection does a TMD trip unit provide?

A TMD trip unit provides thermal protection against sustained overloads and magnetic protection against short-circuit currents, allowing the associated circuit breaker to respond to both types of overcurrent condition.

Trusted ABB Tmax XT Circuit Protection

ABB SACE Tmax XT protection devices are engineered as part of a coordinated moulded-case circuit breaker platform, providing dependable overload and short-circuit protection for professional low-voltage distribution systems.