1SDA062094R1 ABB UVR T7-T7M-X1 415–440 V AC Undervoltage Release

1SDA062094R1 ABB UVR T7-T7M-X1 415–440 V AC Undervoltage Release

ABB 1SDA062094R1 is a 415–440 V AC UVR undervoltage release designed to provide control-supply-dependent opening of compatible SACE Tmax T7 and T7M circuit breakers.

SKU: 1SDA062094R1Alt SKU: UVRT7-T7M-X1415...MPN: 1SDA062094R1
Price
List Price £467.86 ex VAT
Your Price (ex VAT) Save 25%
£350.90 25% OFF
You save £116.97 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £350.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£350.90

Why Choose the ABB 1SDA062094R1 UVR T7-T7M-X1 Undervoltage Release?

The ABB 1SDA062094R1 is a genuine UVR undervoltage release designed for compatible ABB SACE Tmax T7 and T7M circuit breakers. Identified as UVR T7-T7M-X1 415...440Va.c., it operates from a rated control supply of 415–440 V AC and provides an automatic circuit-breaker opening function when the control voltage falls below the required operating level.

An undervoltage release continuously supervises its control supply and acts on the circuit-breaker mechanism if that voltage is lost or sufficiently reduced. This operating principle makes the 1SDA062094R1 suitable for applications where the breaker must open following control-power failure and where closing or remaining closed should depend on the presence of the correct auxiliary voltage.

The 1SDA062094R1 is the uncabled UVR version for the T7-T7M-X1 platform. Its 415–440 V AC rating is specified for both 50 Hz and 60 Hz supplies, making it a purpose-designed ABB accessory for industrial switchboards, electrical interlocking, automation and fail-safe control applications.

Key Advantages

  • Genuine ABB SACE Tmax undervoltage release.
  • Rated for a 415–440 V AC control supply.
  • Suitable for both 50 Hz and 60 Hz AC systems.
  • Provides automatic breaker opening following sufficient loss or reduction of control voltage.
  • Designed for compatible ABB SACE Tmax T7 and T7M equipment.
  • Supports electrical interlocking and fail-safe control schemes.
  • Purpose-designed ABB accessory for reliable integration with the associated breaker mechanism.

Key Features

  • UVR undervoltage release.
  • 415–440 V AC rated control voltage.
  • 50/60 Hz AC operation.
  • Compatible with T7-T7M-X1 applications.
  • Uncabled version.
  • Electrically actuated undervoltage opening function.
  • Designed for continuous supervision of the control supply.
  • Non-delayed version.
  • Loose / configurable accessory.
  • Designed to applicable IEC requirements.
  • ABB order code 1SDA062094R1.

Dependable Undervoltage Release for Controlled Breaker Operation

An undervoltage release is used where the operating state of a circuit breaker must depend on the availability of an auxiliary control supply. During normal operation the UVR is energised, allowing the compatible breaker mechanism to operate. If the control voltage disappears or falls sufficiently below the required level, the release initiates opening, providing a fail-safe response for suitably engineered electrical systems.

The ABB 1SDA062094R1 is specifically designed for 415–440 V AC control circuits and compatible T7-T7M equipment. In withdrawable T7-T7M configurations, the appropriate sliding contact blocks for the fixed and moving parts are required to maintain the auxiliary electrical connections associated with the undervoltage release.

Typical Applications

  • ABB SACE Tmax T7 circuit-breaker installations.
  • Compatible ABB SACE Tmax T7M systems.
  • Industrial low-voltage switchboards.
  • Undervoltage and control-supply-loss protection schemes.
  • Electrical interlocking and fail-safe control circuits.
  • Industrial automation and process-control systems.
  • Power distribution systems requiring control-voltage-dependent breaker operation.

Technical Specifications

Series SACE Tmax T Accessories
Order code 1SDA062094R1
Product type Undervoltage release
Accessory designation UVR
Function Circuit-breaker opening on undervoltage / loss of control supply
Rated control voltage 415–440 V AC
Rated control voltage at 50 Hz 415–440 V AC
Rated control voltage at 60 Hz 415–440 V AC
Current type AC
Compatible platform T7-T7M-X1
Compatible breaker family ABB SACE Tmax T7 / T7M
Version Uncabled
Time delayed No
Configuration type Loose / configurable
Standard IEC
Product net weight 1 kg
Package quantity 1 piece
Package width 105 mm
Package height 55 mm
Package depth / length 135 mm
Package gross weight 0.15 kg
EAN / GTIN 8015644646349
Customs tariff number 85389099
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062094R1 used for?

The ABB 1SDA062094R1 is a UVR undervoltage release used with compatible ABB SACE Tmax T7 and T7M circuit breakers to initiate opening when its control voltage is lost or falls sufficiently below the required operating level.

What is the rated voltage of the ABB 1SDA062094R1?

The 1SDA062094R1 has a rated control voltage of 415–440 V AC for both 50 Hz and 60 Hz supplies.

Which circuit breakers are compatible with the ABB 1SDA062094R1?

The release is designed for compatible ABB SACE Tmax T7 and T7M equipment and is identified as the UVR T7-T7M-X1 version.

What does UVR mean on the ABB 1SDA062094R1?

UVR means undervoltage release. It is an electrically operated accessory that responds to loss or sufficient reduction of its control voltage and initiates opening of the compatible circuit breaker.

Is the ABB 1SDA062094R1 a cabled or uncabled release?

The 1SDA062094R1 is the uncabled UVR version for the T7-T7M platform. Withdrawable T7-T7M configurations require the appropriate sliding contact blocks for the fixed and moving parts.

Trusted ABB Circuit Breaker Accessories

ABB SACE Tmax undervoltage releases provide purpose-designed control of compatible circuit breakers, supporting fail-safe opening, electrical interlocking and control-supply supervision in professional low-voltage switchgear installations.