ABB 1SDA062093R1 is a 380–400 V AC UVR undervoltage release designed to provide control-supply-dependent opening of compatible SACE Tmax T7 and T7M circuit breakers.

SKU: 1SDA062093R1Alt SKU: T7/X1 UVRMPN: 1SDA062093R1
Price
List Price £467.79 ex VAT
Your Price (ex VAT) Save 25%
£350.84 25% OFF
You save £116.95 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £350.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£350.84

Why Choose the ABB 1SDA062093R1 UVR T7-T7M-X1 Undervoltage Release?

The ABB 1SDA062093R1 is a genuine UVR undervoltage release designed for compatible ABB SACE Tmax T7 and T7M circuit breakers. Identified as UVR T7-T7M-X1 380...400Va.c., it operates with a rated control voltage of 380–400 V AC and provides an automatic opening function when the control supply falls below the operating requirements of the release.

Unlike a shunt opening release that trips in response to an applied control voltage, an undervoltage release continuously supervises its supply condition. If the voltage is lost or falls sufficiently, the UVR acts on the circuit-breaker mechanism to initiate opening and helps prevent the breaker from remaining closed or being closed without the required control voltage.

The 1SDA062093R1 is an uncabled UVR version for the T7-T7M platform and forms part of ABB's SACE Tmax electrical accessory system. Its 380–400 V AC rating makes it suitable for industrial control, safety and power-distribution applications where circuit-breaker operation must be dependent on the presence of an appropriate control supply.

Key Advantages

  • Genuine ABB SACE Tmax undervoltage release.
  • Rated for a 380–400 V AC control supply.
  • Provides automatic circuit-breaker opening following loss or sufficient reduction of control voltage.
  • Designed for compatible ABB Tmax T7 and T7M equipment.
  • Supports fail-safe control and electrical interlocking applications.
  • Suitable for industrial switchboards, automation systems and safety-control circuits.
  • Purpose-designed ABB accessory for integration with the associated circuit-breaker mechanism.

Key Features

  • UVR undervoltage release.
  • 380–400 V AC rated control voltage.
  • Compatible with T7-T7M-X1 applications.
  • Uncabled version.
  • Electrically actuated undervoltage opening function.
  • Designed for continuous supervision of the control supply.
  • Supports circuit-breaker opening when the UVR supply is lost or sufficiently reduced.
  • Part of the ABB SACE Tmax T accessory range.
  • Designed to applicable IEC requirements.
  • ABB order code 1SDA062093R1.

Dependable Undervoltage Release for Controlled Breaker Operation

An undervoltage release is used where the operating state of a circuit breaker must depend on the availability of a control supply. During normal conditions the release is energised, allowing the compatible breaker mechanism to remain operational. If the control voltage disappears or falls sufficiently, the release initiates breaker opening, providing a useful fail-safe response in suitably engineered electrical systems.

The ABB 1SDA062093R1 is specifically designed for a 380–400 V AC control supply and compatible T7-T7M equipment. For withdrawable T7-T7M configurations, suitable sliding contact blocks for the fixed and moving parts are required to maintain the auxiliary electrical connections associated with the release.

Typical Applications

  • ABB SACE Tmax T7 circuit-breaker installations.
  • Compatible ABB SACE Tmax T7M systems.
  • Industrial low-voltage switchboards.
  • Undervoltage and supply-loss protection schemes.
  • Electrical interlocking and fail-safe control circuits.
  • Industrial automation and process-control systems.
  • Power distribution systems requiring control-voltage-dependent breaker operation.

Technical Specifications

Series SACE Tmax T Accessories
Order code 1SDA062093R1
Product type Undervoltage release
Accessory designation UVR
Function Circuit-breaker opening on undervoltage / loss of control supply
Rated control voltage 380–400 V AC
Voltage type AC
Compatible platform T7-T7M-X1
Compatible breaker family ABB SACE Tmax T7 / T7M
Version Uncabled
Standard IEC
Package gross weight 0.15 kg
Package width 105 mm
Package height 55 mm
Package length 135 mm
EAN / GTIN 8015644646332
Country of origin Italy
Customs tariff / HSN 85389099
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062093R1 used for?

The ABB 1SDA062093R1 is a UVR undervoltage release used with compatible ABB SACE Tmax T7 and T7M circuit breakers to initiate opening when its control supply falls below the required operating condition.

What is the rated voltage of the ABB 1SDA062093R1?

The 1SDA062093R1 has a rated control voltage of 380–400 V AC.

Which circuit breakers are compatible with the ABB 1SDA062093R1?

The release is designed for compatible ABB SACE Tmax T7 and T7M equipment and is identified by ABB as the UVR T7-T7M-X1 version.

What does UVR mean on the ABB 1SDA062093R1?

UVR means undervoltage release. It is an electrically operated circuit-breaker accessory designed to respond when its control supply is lost or falls sufficiently below its normal operating condition.

Is the ABB 1SDA062093R1 a cabled or uncabled release?

The 1SDA062093R1 is the uncabled UVR version for the T7-T7M platform. Withdrawable T7-T7M configurations require the appropriate sliding contact blocks for the fixed and moving portions of the installation.

Trusted ABB Circuit Breaker Accessories

ABB SACE Tmax undervoltage releases provide purpose-designed control of compatible circuit breakers, supporting fail-safe opening, electrical interlocking and control-supply supervision in professional low-voltage switchgear installations.