1SDA060605R1 ABB PR222DS/P-LSIG 1000A 4-Pole T6 1000 Electronic Trip Unit

1SDA060605R1 ABB PR222DS/P-LSIG 1000A 4-Pole T6 1000 Electronic Trip Unit

ABB 1SDA060605R1 is a 1000 A four-pole PR222DS/P-LSIG electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection for compatible SACE Tmax T6 1000 circuit breaker assemblies.

SKU: 1SDA060605R1MPN: 1SDA060605R1
Price
List Price £3,272.66 ex VAT
Your Price (ex VAT) Save 25%
£2,454.50 25% OFF
You save £818.17 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,454.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,454.50

Why Choose the ABB PR222DS/P-LSIG 1000 A 4-Pole Electronic Trip Unit?

The ABB PR222DS/P-LSIG, order code 1SDA060605R1, is a 1000 A, 4-pole electronic trip unit designed for compatible ABB SACE Tmax T6 1000 moulded case circuit breaker configurations. It provides advanced electronic protection for high-current low-voltage distribution systems.

The LSIG protection configuration combines long-time, short-time, instantaneous and ground-fault protection. This allows the trip unit to protect against overloads and multiple forms of short-circuit fault while also providing ground-fault protection for suitably configured four-pole distribution systems.

The PR222DS/P belongs to ABB's electronic protection system for the Tmax T6 platform and is rated at 1000 A for this specific version. As a trip-unit component rather than a complete MCCB, the 1SDA060605R1 is intended to be used with the corresponding compatible T6 1000 breaker assembly.

Key Advantages

  • 1000 A rated current for compatible high-current Tmax T6 1000 applications.
  • LSIG protection provides four principal electronic protection functions.
  • Long-time protection for overload conditions.
  • Short-time protection supports selective short-circuit coordination.
  • Instantaneous protection provides rapid response to severe short-circuit faults.
  • Ground-fault protection adds protection against earth-fault conditions.
  • 4-pole configuration for compatible four-pole T6 1000 breaker assemblies.
  • Original ABB electronic protection component for the SACE Tmax platform.

Key Features

  • ABB PR222DS/P-LSIG electronic trip unit.
  • Designed for the SACE Tmax T6 1000 platform.
  • Rated current: 1000 A.
  • 4-pole configuration.
  • Electronic release technology.
  • LSIG protection functionality.
  • L: long-time overload protection.
  • S: short-time short-circuit protection.
  • I: instantaneous short-circuit protection.
  • G: ground-fault protection.

Comprehensive LSIG Protection for Tmax T6 1000 Assemblies

The PR222DS/P-LSIG combines the principal electronic protection functions required in demanding distribution systems. Long-time protection responds to sustained overload conditions, short-time protection supports selective coordination, instantaneous protection responds rapidly to severe short circuits, and the ground-fault function provides an additional layer of protection against earth-fault conditions.

The ABB 1SDA060605R1 is specifically configured for a 1000 A, four-pole Tmax T6 1000 application. Because it is the electronic trip unit rather than the complete moulded case circuit breaker, it must be combined with the appropriate compatible ABB T6 1000 breaking part and associated components to form the required circuit breaker assembly.

Typical Applications

  • Compatible ABB SACE Tmax T6 1000 circuit breaker assemblies.
  • High-current four-pole low-voltage distribution systems.
  • Main distribution switchboards.
  • Industrial feeder protection.
  • Manufacturing and process plant electrical distribution.
  • Systems requiring LSIG electronic protection.
  • Distribution systems requiring ground-fault protection and selective coordination.

Technical Specifications

Series SACE Tmax T6
Order code 1SDA060605R1
Product type Electronic trip unit
Compatible frame Tmax T6 1000
Rated current (In) 1000 A
Number of poles 4
Trip-unit family PR222DS/P
Protection configuration LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Ground-fault protection G
Release technology Electronic
Application Compatible ABB SACE Tmax T6 1000 MCCB assemblies

Frequently Asked Questions

What is the ABB 1SDA060605R1?

The ABB 1SDA060605R1 is a PR222DS/P-LSIG 1000 A, 4-pole electronic trip unit for compatible ABB SACE Tmax T6 1000 moulded case circuit breaker assemblies.

What protection functions does the ABB PR222DS/P-LSIG provide?

The trip unit provides LSIG protection: long-time overload protection, short-time short-circuit protection, instantaneous short-circuit protection and ground-fault protection.

What is the rated current of the ABB 1SDA060605R1?

The 1SDA060605R1 is rated at 1000 A.

How many poles is the ABB PR222DS/P-LSIG 1SDA060605R1 designed for?

This specific trip-unit configuration is designed for a compatible 4-pole Tmax T6 1000 circuit breaker assembly.

Does the ABB 1SDA060605R1 provide ground-fault protection?

Yes. The G in its LSIG designation identifies the ground-fault protection function.

Is the ABB 1SDA060605R1 a complete moulded case circuit breaker?

No. The 1SDA060605R1 is an electronic trip unit, not a complete MCCB. It is intended to be combined with the appropriate compatible Tmax T6 1000 breaker components.

Which ABB circuit breaker platform is compatible with the 1SDA060605R1?

The 1SDA060605R1 is specified for the ABB SACE Tmax T6 1000 platform in a four-pole configuration.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax electronic protection units are used by panel builders, electrical engineers and industrial operators to configure coordinated low-voltage circuit protection for demanding commercial, infrastructure and industrial power distribution systems.