1SDA060600R1 ABB PR222DS/PD-LSI 1000 A T6 1000 3-Pole Trip Unit

1SDA060600R1 ABB PR222DS/PD-LSI 1000 A T6 1000 3-Pole Trip Unit

ABB 1SDA060600R1 is a 1000 A PR222DS/PD-LSI electronic trip unit with digital communication capability, providing long-time, short-time and instantaneous protection for compatible three-pole SACE Tmax T6 1000 circuit breakers.

SKU: 1SDA060600R1MPN: 1SDA060600R1
Price
List Price £4,472.39 ex VAT
Your Price (ex VAT) Save 25%
£3,354.29 25% OFF
You save £1,118.10 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,354.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,354.29

Why Choose the ABB 1SDA060600R1 PR222DS/PD-LSI Trip Unit?

The ABB 1SDA060600R1 is an advanced electronic protection trip unit designed for compatible ABB SACE Tmax T6 1000 moulded-case circuit breakers. Identified as PR222DS/PD-LSI In=1000 T6 1000 3p, this three-pole release has a rated current of 1000 A and provides comprehensive protection for high-current low-voltage distribution circuits.

As part of the ABB SACE Tmax T6 protection system, the PR222DS/PD uses electronic current measurement and processing to provide accurate circuit protection. Its LSI functions provide long-time overload, short-time short-circuit and instantaneous short-circuit protection, supporting effective protection coordination in industrial and commercial power distribution systems.

The PR222DS/PD version adds digital communication capability to the PR222 protection platform, supporting integration of circuit-breaker information into compatible monitoring and automation systems. This 1SDA060600R1 variant is specifically rated at 1000 A for three-pole Tmax T6 1000 circuit-breaker applications.

Key Advantages

  • Genuine ABB SACE Tmax electronic protection release.
  • 1000 A rated current for T6 1000 applications.
  • Comprehensive LSI protection functions.
  • Provides long-time overload, short-time and instantaneous short-circuit protection.
  • PR222DS/PD communication-capable design for integration with compatible monitoring systems.
  • Designed specifically for compatible ABB Tmax T6 1000 three-pole circuit breakers.

Key Features

  • ABB PR222DS/PD electronic trip unit.
  • LSI protection functionality.
  • 1000 A rated current (In).
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Digital communication capability.
  • Three-pole configuration.
  • Designed for compatible ABB SACE Tmax T6 1000 breaker bodies.
  • Electronic protection supports coordinated low-voltage distribution systems.
  • ABB order code 1SDA060600R1.

Advanced Electronic Protection and Communication

Electronic trip units monitor current flowing through a circuit breaker and initiate tripping when configured protection thresholds are exceeded. The ABB PR222DS/PD-LSI provides long-time protection against sustained overloads, short-time protection for controlled response to short-circuit conditions and instantaneous protection for rapid interruption of severe faults.

The PR222DS/PD platform also supports digital communication, allowing compatible circuit-breaker information to be incorporated into supervisory and automation architectures. This combination of electronic LSI protection and communication capability makes the release well suited to modern industrial distribution systems requiring both dependable circuit protection and enhanced system visibility.

Typical Applications

  • Industrial main distribution switchboards.
  • ABB Tmax T6 1000 circuit-breaker assemblies.
  • High-current feeder protection.
  • Manufacturing and process-industry power systems.
  • Commercial and infrastructure electrical distribution.
  • Power systems requiring electronic protection and communication capability.

Technical Specifications

Series SACE Tmax T6
Order code 1SDA060600R1
Product type Electronic circuit-breaker trip unit / protection release
Trip unit PR222DS/PD
Protection functions LSI
Long-time protection L
Short-time protection S
Instantaneous protection I
Rated current (In) 1000 A
Compatible breaker frame Tmax T6 1000
Number of poles 3
Release technology Electronic
Communication Digital communication capability
Application Low-voltage circuit-breaker protection and monitoring
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA060600R1 used for?

The ABB 1SDA060600R1 is a PR222DS/PD electronic trip unit used to provide LSI protection for compatible ABB SACE Tmax T6 1000 three-pole moulded-case circuit breakers.

What is the rated current of the ABB PR222DS/PD-LSI 1SDA060600R1?

This version of the PR222DS/PD trip unit has a rated current of 1000 A.

What does LSI mean on the PR222DS/PD trip unit?

LSI represents long-time overload, short-time short-circuit and instantaneous short-circuit protection functions.

Which circuit breaker is compatible with the ABB 1SDA060600R1?

The trip unit is designed for compatible ABB SACE Tmax T6 1000 three-pole moulded-case circuit breakers.

Does the ABB PR222DS/PD support communication?

Yes. The PR222DS/PD is a communication-capable electronic release designed to support integration with compatible ABB monitoring and automation systems.

Trusted ABB Circuit Breaker Protection

ABB SACE Tmax electronic trip units provide accurate, configurable protection and advanced system integration capabilities for professional low-voltage power distribution systems.