1SDA060358R1 ABB PR221DS-I 630A T6 4-Pole Electronic Trip Unit

1SDA060358R1 ABB PR221DS-I 630A T6 4-Pole Electronic Trip Unit

ABB 1SDA060358R1 is a 630 A four-pole PR221DS-I solid-state electronic trip unit for compatible Tmax T6 moulded case circuit breakers, providing instantaneous short-circuit protection.

SKU: 1SDA060358R1MPN: 1SDA060358R1
Price
List Price £1,940.00 ex VAT
Your Price (ex VAT) Save 25%
£1,455.00 25% OFF
You save £485.00 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,455.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,455.00

Why Choose the ABB PR221DS-I 630A T6 4-Pole Electronic Trip Unit?

The ABB PR221DS-I In=630 T6 630 4P, order code 1SDA060358R1, is a solid-state electronic trip unit designed for compatible ABB SACE Tmax T6 moulded case circuit breakers. Part of the established ABB Tmax T6 protection platform, this release provides instantaneous short-circuit protection for high-current low-voltage electrical distribution systems.

Rated at 630 A, the PR221DS-I monitors current through the associated circuit breaker and initiates tripping when the instantaneous protection threshold is exceeded. The I-only protection characteristic is intended for applications where rapid short-circuit protection is required and overload protection is provided separately or is not required from the circuit breaker trip unit.

This version is specifically configured for 4-pole Tmax T6 circuit breaker assemblies. Its electronic protection technology, 630 A current rating and four-pole construction make the 1SDA060358R1 suitable for compatible three-phase plus neutral distribution systems requiring dependable instantaneous fault protection.

Key Advantages

  • Dedicated electronic trip unit for ABB Tmax T6 circuit breakers.
  • 630 A rated current for high-current distribution applications.
  • Instantaneous short-circuit protection for rapid response to severe fault currents.
  • Solid-state protection technology provides accurate electronic current monitoring.
  • 4-pole configuration for compatible three-phase plus neutral Tmax T6 assemblies.
  • Designed for integration with compatible ABB Tmax T6 breaking parts and circuit breaker components.

Key Features

  • ABB PR221DS-I solid-state electronic release.
  • Designed for the ABB SACE Tmax T6 platform.
  • 630 A rated current.
  • 4-pole configuration.
  • I protection function for instantaneous short-circuit faults.
  • Electronic current sensing and breaker tripping.
  • Suitable for compatible Tmax T6 moulded case circuit breaker assemblies.
  • Designed for high-current industrial power distribution applications.

Reliable Instantaneous Protection for Tmax T6 Circuit Breakers

Electronic instantaneous trip units are designed to detect severe overcurrent conditions and command the associated circuit breaker to open rapidly when the configured fault threshold is exceeded. This helps limit the thermal and mechanical stresses that high short-circuit currents can impose on conductors, switchgear and connected electrical equipment.

The ABB PR221DS-I combines a 630 A current rating with an instantaneous protection characteristic in a four-pole configuration. When installed in a compatible Tmax T6 assembly, it provides focused electronic short-circuit protection for industrial feeders, distribution circuits and other high-current electrical systems.

Typical Applications

  • ABB Tmax T6 moulded case circuit breaker assemblies.
  • Industrial low-voltage distribution boards.
  • Three-phase plus neutral electrical systems.
  • High-current feeder circuits.
  • Manufacturing and process plant switchgear.
  • Machinery and industrial power distribution panels.

Technical Specifications

Series SACE Tmax T6
Order code 1SDA060358R1
Product type Solid-state electronic trip unit
Compatible frame Tmax T6
Trip unit PR221DS-I
Rated current (In) 630 A
Number of poles 4
Protection technology Electronic / solid-state
Protection function Instantaneous short-circuit protection (I)
Compatible equipment ABB Tmax T6 moulded case circuit breakers

Frequently Asked Questions

What is the ABB 1SDA060358R1?

The ABB 1SDA060358R1 is a PR221DS-I solid-state electronic trip unit rated at 630 A for compatible 4-pole ABB Tmax T6 moulded case circuit breaker assemblies.

What protection function does the PR221DS-I provide?

The PR221DS-I provides instantaneous short-circuit protection, identified by the I protection function.

What is the rated current of the ABB 1SDA060358R1?

The PR221DS-I trip unit has a rated current of 630 A.

How many poles is the ABB 1SDA060358R1 designed for?

This order code identifies the 4-pole version of the PR221DS-I 630 A trip unit for compatible ABB Tmax T6 circuit breakers.

Does the PR221DS-I provide thermal overload protection?

This PR221DS-I configuration is identified by its instantaneous I protection function; applications requiring overload protection should use the appropriate separately provided or compatible protection arrangement.

Which circuit breaker platform is the 1SDA060358R1 designed for?

The 1SDA060358R1 is designed for compatible ABB SACE Tmax T6 moulded case circuit breaker configurations.

Trusted by Electrical Professionals Worldwide

ABB Tmax protection units are used by panel builders, electrical engineers and industrial operators to provide dependable short-circuit protection within high-performance low-voltage power distribution systems.