ABB 1SDA060356R1 is a 630 A three-pole PR222DS/PD-LSIG solid-state electronic trip unit for compatible SACE Tmax T6 630 circuit breakers, providing long-time, short-time, instantaneous and ground-fault protection with communication capability.

SKU: 1SDA060356R1MPN: 1SDA060356R1
Price
List Price £5,315.88 ex VAT
Your Price (ex VAT) Save 25%
£3,986.91 25% OFF
You save £1,328.97 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,986.91
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,986.91

Why Choose the ABB PR222DS/PD-LSIG 1SDA060356R1 Electronic Trip Unit?

The ABB 1SDA060356R1 is a PR222DS/PD-LSIG three-pole electronic trip unit designed for compatible ABB SACE Tmax T6 630 moulded-case circuit breakers. Rated at 630 A, it provides comprehensive electronic protection for demanding industrial and commercial low-voltage power distribution systems.

The PR222DS/PD-LSIG provides long-time, short-time, instantaneous and ground-fault protection functions. This LSIG configuration enables the associated Tmax T6 circuit breaker to respond to sustained overloads, delayed short-circuit conditions, severe instantaneous faults and ground faults, supporting effective protection coordination throughout the electrical installation.

The PD version incorporates communication functionality, allowing the electronic release to be integrated with compatible ABB supervision and power-management architectures. Combining 630 A capacity, three-pole operation, LSIG protection and communication capability, the 1SDA060356R1 is suited to applications requiring advanced circuit protection and enhanced system visibility.

Key Advantages

  • Genuine ABB PR222DS/PD-LSIG electronic trip unit for compatible Tmax T6 circuit breakers.
  • 630 A rated current for T6 630 applications.
  • LSIG protection covering overload, short-time, instantaneous and ground-fault conditions.
  • PD communication functionality for compatible monitoring and power-management systems.
  • Three-pole configuration for three-phase circuit protection.
  • Adjustable electronic protection supports improved selectivity and coordination within distribution systems.

Key Features

  • ABB PR222DS/PD-LSIG solid-state electronic release.
  • Designed for ABB SACE Tmax T6 630 circuit breakers.
  • 630 A rated current (In).
  • Three-pole (3P) configuration.
  • Long-time (L) overload protection.
  • Short-time (S) delayed short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection with PD communication capability.

How Does the ABB PR222DS/PD-LSIG Electronic Trip Unit Work?

An electronic trip unit monitors electrical current through the associated circuit breaker and commands the breaker to trip when configured protection thresholds and timing conditions are reached. The LSIG functions provide long-time protection against sustained overloads, short-time protection for coordinated short circuits, instantaneous protection for severe faults and ground-fault protection for current flowing through unintended earth paths.

The PR222DS/PD configuration extends these protection functions with communication capability, enabling compatible monitoring and supervision systems to interact with the protection architecture. This combination makes the 1SDA060356R1 particularly useful in Tmax T6 630 installations where comprehensive LSIG protection and communication functionality are required.

Typical Applications

  • ABB SACE Tmax T6 630 circuit-breaker assemblies.
  • Industrial low-voltage power distribution systems.
  • Main and sub-main feeder protection.
  • Switchboards requiring electronic LSIG protection.
  • Distribution systems requiring ground-fault protection and communication capability.
  • Replacement or maintenance of compatible PR222DS/PD-equipped Tmax T6 breakers.

Technical Specifications

Series SACE Tmax T / Tmax T4–T8
Order code 1SDA060356R1
Product type Solid-state electronic trip unit / protection release
Compatible breaker frame Tmax T6
Compatible breaker rating T6 630
Rated current (In) 630 A
Number of poles 3
Application AC power circuit breaker protection
Protection functions Long-time, short-time, instantaneous and ground-fault (LSIG)
Long-time function Overload protection
Short-time function Delayed short-circuit protection
Instantaneous function High-level short-circuit protection
Ground-fault function Ground-fault protection
Communication capability Yes, PD version
Suitable for power circuit breakers Yes
Suitable for load switches No
Suitable for motor-protection circuit breakers No
Product range SACE Tmax T
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA060356R1?

The ABB 1SDA060356R1 is a PR222DS/PD-LSIG three-pole solid-state electronic trip unit rated at 630 A for compatible ABB SACE Tmax T6 630 moulded-case circuit breakers.

What does LSIG mean on the ABB PR222DS/PD-LSIG?

LSIG denotes long-time (L), short-time (S), instantaneous (I) and ground-fault (G) protection, providing comprehensive electronic protection against overloads, short circuits and ground faults.

What is the current rating of the ABB 1SDA060356R1?

The PR222DS/PD-LSIG 1SDA060356R1 has a rated current of 630 A and is intended for the compatible ABB Tmax T6 630 circuit-breaker platform.

Does the ABB 1SDA060356R1 provide ground-fault protection?

Yes. The G function in LSIG provides ground-fault protection in addition to long-time overload, short-time and instantaneous short-circuit protection.

What does PD mean on the ABB PR222DS/PD-LSIG?

The PD designation identifies a communication-enabled version of the PR222DS electronic protection platform, allowing integration with compatible ABB circuit-breaker monitoring, supervision and power-management systems.

Trusted ABB Electronic Circuit Protection

ABB SACE Tmax electronic releases provide configurable protection for demanding low-voltage distribution systems, with the PR222DS/PD-LSIG combining 630 A T6 protection, comprehensive LSIG fault functions and communication capability for integrated industrial power-management applications.