ABB 1SDA060347R1 is a TMA 630-6300 three-pole thermomagnetic trip unit for compatible Tmax T6 circuit breakers, rated at 630 A with an adjustable 3150–6300 A magnetic short-circuit trip threshold.

SKU: 1SDA060347R1Alt SKU: TMA630-6300T66303PMPN: 1SDA060347R1
Price
List Price £1,552.00 ex VAT
Your Price (ex VAT) Save 25%
£1,164.00 25% OFF
You save £388.00 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,164.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,164.00

Why Choose the ABB TMA 630-6300 T6 630 3-Pole Thermomagnetic Trip Unit?

The ABB TMA 630-6300 T6 630 3P, order code 1SDA060347R1, is a thermomagnetic trip unit designed for compatible ABB SACE Tmax T6 moulded case circuit breakers. Part of the proven ABB Tmax T6 series, it provides overload and short-circuit protection for high-current low-voltage electrical distribution applications.

The trip unit has a rated current of 630 A and combines thermal overload protection with adjustable magnetic instantaneous protection. Its magnetic trip threshold I3 is adjustable from 3150 to 6300 A, allowing the short-circuit protection response to be matched to the requirements of the protected circuit and installation.

Designed specifically for 3-pole Tmax T6 circuit breaker configurations, the TMA 630-6300 provides straightforward thermomagnetic protection without requiring an electronic protection release. Its robust operating principle makes it suitable for industrial switchboards, feeder circuits and distribution systems requiring dependable overload and short-circuit protection.

Key Advantages

  • Dedicated thermomagnetic trip unit for ABB Tmax T6 circuit breakers.
  • 630 A rated current for high-current distribution applications.
  • Provides both thermal overload and magnetic short-circuit protection.
  • Adjustable magnetic trip threshold from 3150 to 6300 A.
  • 3-pole configuration for compatible three-phase Tmax T6 assemblies.
  • Thermomagnetic operation provides dependable protection without an electronic trip unit.

Key Features

  • ABB TMA 630-6300 thermomagnetic release.
  • Designed for the ABB SACE Tmax T6 platform.
  • 630 A nominal current.
  • 3150–6300 A adjustable magnetic trip threshold (I3).
  • Thermal protection for sustained overload conditions.
  • Magnetic protection for high short-circuit currents.
  • 3-pole version.
  • Suitable for compatible T6 breaking parts and circuit breaker assemblies.

Reliable Thermomagnetic Protection for Tmax T6 Circuit Breakers

Thermomagnetic trip units protect electrical circuits using two complementary operating principles. The thermal element responds to sustained overload currents, while the magnetic element reacts rapidly to high short-circuit currents, enabling the associated circuit breaker to disconnect the affected circuit when damaging overcurrent conditions occur.

The ABB TMA 630-6300 combines a 630 A nominal current rating with an adjustable 3150–6300 A magnetic threshold. This allows compatible Tmax T6 circuit breaker assemblies to provide robust protection for high-current feeders, distribution circuits and industrial electrical equipment.

Typical Applications

  • ABB Tmax T6 moulded case circuit breaker assemblies.
  • Industrial low-voltage distribution boards.
  • Main and feeder circuit protection.
  • Manufacturing and process plant switchgear.
  • High-current three-phase distribution systems.
  • Machinery and industrial power distribution panels.

Technical Specifications

Series SACE Tmax T6
Order code 1SDA060347R1
Product type Thermomagnetic trip unit
Compatible frame Tmax T6
Trip unit type TMA
Rated current (In) 630 A
Magnetic trip threshold (I3) 3150–6300 A
Magnetic adjustment range 5–10 × In
Number of poles 3
Protection technology Thermomagnetic
Overload protection Thermal
Short-circuit protection Adjustable instantaneous magnetic

Frequently Asked Questions

What is the ABB 1SDA060347R1?

The ABB 1SDA060347R1 is a TMA 630-6300 thermomagnetic trip unit rated at 630 A for compatible 3-pole ABB Tmax T6 circuit breaker configurations.

What is the rated current of the ABB TMA 630-6300?

The TMA 630-6300 trip unit has a rated current of 630 A.

What is the magnetic trip range of the ABB 1SDA060347R1?

The magnetic instantaneous trip threshold I3 is adjustable from 3150 to 6300 A, equivalent to approximately 5–10 times the 630 A rated current.

What protection does the TMA 630-6300 provide?

The trip unit combines thermal overload protection with adjustable magnetic short-circuit protection.

Which ABB circuit breaker frame is the 1SDA060347R1 designed for?

The 1SDA060347R1 is designed for compatible ABB SACE Tmax T6 moulded case circuit breaker configurations.

How many poles is this TMA trip unit designed for?

This order code identifies the 3-pole version of the TMA 630-6300 trip unit for the Tmax T6 platform.

Trusted by Electrical Professionals Worldwide

ABB Tmax circuit breaker protection units are used by panel builders, electrical engineers and industrial operators to provide dependable overload and short-circuit protection in demanding power distribution installations.