1SDA059769R1 ABB E6/f W FP 4p HR-HR New Fixed Part 6300 A 690 V

1SDA059769R1 ABB E6/f W FP 4p HR-HR New Fixed Part 6300 A 690 V

ABB 1SDA059769R1 E6/f W FP is a 6300 A, 690 V AC full-size four-pole SACE Emax fixed part for withdrawable E6/f air circuit breakers with horizontal rear upper and lower terminals.

SKU: 1SDA059769R1Alt SKU: E6FPMPN: 1SDA059769R1
Price
List Price £9,533.28 ex VAT
Your Price (ex VAT) Save 25%
£7,149.96 25% OFF
You save £2,383.32 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,149.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,149.96

Why Choose the ABB E6/f W FP 4p HR-HR New Fixed Part?

The ABB E6/f W FP 4p HR-HR new, order code 1SDA059769R1, is a heavy-duty SACE Emax E6/f fixed part for withdrawable air circuit breakers designed for very high-current industrial low-voltage power distribution systems. As part of the ABB New Emax family, it provides the permanently installed mechanical and electrical interface required for a compatible full-size four-pole E6/f withdrawable circuit breaker.

This fixed part features a four-pole full-size configuration with horizontal rear terminals at both the upper and lower connections. Unlike the standard E6 four-pole arrangement with a reduced fourth pole, the E6/f configuration uses a full-size fourth pole, making it suitable for installations requiring full current capability across all four poles.

With a rated uninterrupted current of 6300 A and a rated voltage of 690 V AC, the 1SDA059769R1 is engineered for exceptionally demanding power distribution duties. Its withdrawable architecture, substantial E6/f frame and HR-HR connection arrangement make it well suited to main switchboards and engineered distribution systems where high current capacity, neutral switching and serviceability are essential.

Key Advantages

  • Genuine ABB SACE Emax E6/f fixed part for compatible withdrawable air circuit breakers.
  • 6300 A rated uninterrupted current for very high-current power distribution.
  • 690 V AC rated voltage for demanding industrial low-voltage systems.
  • Four-pole full-size configuration for applications requiring full-capacity neutral switching.
  • Upper and lower horizontal rear terminals suit horizontal busbar arrangements.
  • Withdrawable architecture facilitates circuit breaker inspection, maintenance and replacement.

Key Features

  • ABB SACE Emax / New Emax E6/f series.
  • WFP fixed-part version.
  • 4-pole full-size (4/f) configuration.
  • 6300 A rated uninterrupted current (Iu).
  • 690 V AC rated voltage (Ur).
  • Horizontal rear upper terminals (HR).
  • Horizontal rear lower terminals (HR).
  • Designed for compatible withdrawable E6/f air circuit breakers.
  • Heavy-duty construction for high-capacity industrial switchgear.
  • Designed in accordance with applicable IEC requirements.

Reliable High-Current Circuit Breaker Integration

A fixed part forms the permanently installed section of a withdrawable air circuit breaker assembly, providing the mechanical mounting and electrical connections between the removable breaker and the switchboard. This arrangement enables a compatible E6/f circuit breaker to be withdrawn for inspection, maintenance or replacement while the fixed assembly remains installed in the switchgear.

The ABB 1SDA059769R1 combines an exceptional 6300 A current capability with a full-size four-pole design and horizontal rear connections. This configuration is particularly suited to high-capacity distribution systems where the neutral pole requires full-size construction and the switchboard busbar architecture favours rear horizontal connections.

Typical Applications

  • Very high-current industrial low-voltage switchboards.
  • Main incoming and power distribution assemblies.
  • Four-pole three-phase systems requiring full-size neutral switching.
  • Withdrawable air circuit breaker installations.
  • Manufacturing and process plant electrical distribution.
  • Infrastructure and utility power distribution systems.
  • OEM switchgear and engineered panel-building applications.

Technical Specifications

Series SACE Emax / New Emax
Designation E6/f W FP 4p HR-HR new
ABB order code 1SDA059769R1
Product type Fixed part for withdrawable air circuit breaker
Version WFP
Sub-type E6
Number of poles 4 / f
Fourth-pole configuration Full size
Rated uninterrupted current (Iu) 6300 A
Rated voltage (Ur) 690 V
Current type AC
Terminal connection Rear flat horizontal
Upper terminal orientation Horizontal rear (HR)
Lower terminal orientation Horizontal rear (HR)
Circuit-breaker execution Withdrawable
Standards IEC
Dimensions (W × H × D) 1062 × 461 × 396.5 mm
Product net weight 115 kg
EAN 8015644621933
Product group 310513 – New Emax

Frequently Asked Questions

What is the ABB 1SDA059769R1 used for?

The ABB 1SDA059769R1 is a fixed part for a compatible SACE Emax E6/f withdrawable air circuit breaker, providing the stationary mechanical and electrical interface within a switchboard.

What is the current rating of the ABB 1SDA059769R1?

The fixed part has a rated uninterrupted current (Iu) of 6300 A, making it suitable for very high-current industrial power distribution systems.

What voltage is the ABB E6/f W FP 4p HR-HR rated for?

The ABB 1SDA059769R1 has a rated voltage (Ur) of 690 V AC.

What does the E6/f designation mean?

The E6/f designation identifies the full-size four-pole E6 configuration, providing a full-size fourth pole rather than the reduced fourth-pole arrangement used on the standard E6 four-pole version.

What does HR-HR mean on the ABB E6/f W FP?

The HR-HR designation means the fixed part uses horizontal rear terminals at both the upper and lower connections.

Trusted by Industrial Electrical Professionals Worldwide

ABB SACE Emax equipment is widely used in industrial power distribution systems where very high-current capability, robust construction and serviceable withdrawable circuit breaker arrangements are required.