1SDA059764R1 ABB E2S W FP 4P HR-HR SACE Emax Fixed Part 2000 A

1SDA059764R1 ABB E2S W FP 4P HR-HR SACE Emax Fixed Part 2000 A

ABB 1SDA059764R1 SACE Emax E2S four-pole fixed part rated at 2000 A and 690 V with HR-HR horizontal rear terminals for compatible withdrawable E2S air circuit breakers.

SKU: 1SDA059764R1Alt SKU: E25MPN: 1SDA059764R1
Price
List Price £3,498.80 ex VAT
Your Price (ex VAT) Save 25%
£2,624.10 25% OFF
You save £874.70 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,624.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,624.10

Why Choose the ABB 1SDA059764R1 E2S W Fixed Part?

The ABB 1SDA059764R1 is a SACE Emax E2S fixed part designed for use with compatible withdrawable ABB E2S air circuit breakers. Identified by ABB as E2S W FP 4p HR-HR new, this four-pole fixed section forms the stationary component of a withdrawable circuit-breaker installation, providing the mechanical interface and main power connections required within low-voltage electrical switchgear.

Designed for the ABB SACE Emax E2S frame, the 1SDA059764R1 has a rated uninterrupted current of 2000 A and a rated voltage of 690 V. Its four-pole configuration supports three-phase four-wire distribution systems, while the HR-HR arrangement provides horizontal rear terminals at both the upper and lower main connections.

The fixed part remains installed within the switchboard while a compatible withdrawable E2S circuit-breaker moving part can be inserted, isolated and removed as required. This modular arrangement supports efficient maintenance and replacement while retaining the fixed power connections within the switchgear assembly.

Key Advantages

  • Genuine ABB SACE Emax E2S fixed part for withdrawable air circuit breakers.
  • 2000 A rated uninterrupted current for high-current power distribution.
  • Four-pole configuration for three-phase four-wire electrical systems.
  • 690 V rated voltage for industrial low-voltage distribution applications.
  • HR-HR horizontal rear terminal arrangement at both upper and lower connections.
  • Designed specifically for compatible E2S withdrawable circuit-breaker moving parts.
  • Fixed switchboard installation allows the breaker moving part to be isolated and removed independently.
  • Robust construction for demanding industrial and commercial switchgear installations.

Key Features

  • ABB SACE Emax E2S series.
  • Fixed part (FP) for a withdrawable circuit-breaker system.
  • 2000 A rated uninterrupted current.
  • 690 V rated voltage.
  • Four-pole (4P) configuration.
  • HR-HR horizontal rear terminals.
  • Designed for the E2S frame.
  • Withdrawable circuit-breaker connection type.
  • Bolted main-circuit connection.
  • Built-in switchboard installation.
  • Designed to IEC requirements.

Fixed Part for Withdrawable Emax Circuit Breaker Installations

Withdrawable air circuit-breaker systems separate the assembly into a removable circuit-breaker moving part and a permanently installed fixed part. The ABB 1SDA059764R1 provides the stationary interface for compatible E2S equipment, allowing the circuit breaker to be connected to, isolated from and removed from the electrical system while the principal switchboard connections remain in position.

The HR-HR terminal configuration provides horizontal rear connections at both the upper and lower sides of the fixed part. This arrangement supports switchboard designs using horizontally orientated rear busbar and conductor connections, while the four-pole construction accommodates applications requiring a switched neutral alongside the three phase conductors.

Typical Applications

  • ABB SACE Emax E2S withdrawable circuit-breaker installations.
  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and switchgear assemblies.
  • Three-phase four-wire power distribution systems.
  • Manufacturing and process plant power distribution.
  • Commercial and industrial building distribution systems.
  • Transformer and generator distribution switchboards.
  • Switchgear requiring removable and serviceable air circuit breakers.

Technical Specifications

Series SACE Emax
Product group 310513-New Emax
Reference E25
Order code / MPN 1SDA059764R1
Product type Fixed part for withdrawable air circuit breaker
Frame / sub-type E2S
Version WFP
Rated uninterrupted current (Iu) 2000 A
Rated voltage (Ur) 690 V
Current type AC
Number of poles 4P
Terminal configuration HR-HR
Upper terminal orientation Horizontal rear (HR)
Lower terminal orientation Horizontal rear (HR)
Main-circuit connection Bolted connection
Installation Built-in switchboard installation
Busbar adapter execution No
Standards IEC
Dimensions (W × H × D) 414 × 461 × 396.5 mm
Net weight 39 kg
EAN 8015644621889

Frequently Asked Questions

What is the ABB 1SDA059764R1?

The ABB 1SDA059764R1 is a SACE Emax E2S four-pole fixed part designed for use with compatible withdrawable E2S air circuit breakers in low-voltage switchgear.

What is the current rating of the ABB 1SDA059764R1?

The fixed part has a rated uninterrupted current of 2000 A and a rated voltage of 690 V.

Is the ABB 1SDA059764R1 a complete air circuit breaker?

No. The 1SDA059764R1 is the fixed part of a withdrawable ABB SACE Emax E2S circuit-breaker system. A compatible E2S moving circuit-breaker section is required to form the complete withdrawable assembly.

What does HR-HR mean on the ABB 1SDA059764R1?

HR-HR identifies the terminal arrangement, with horizontal rear terminals provided at both the upper and lower main-circuit connections.

What are the dimensions of the ABB 1SDA059764R1?

The fixed part measures 414 × 461 × 396.5 mm (width × height × depth) and has a net weight of 39 kg.

Trusted ABB Power Distribution Technology

ABB SACE Emax withdrawable circuit-breaker systems provide robust and serviceable solutions for demanding electrical distribution installations, with dedicated fixed parts allowing compatible breaker moving sections to be isolated, serviced and replaced while the main switchboard connections remain installed.