ABB 1SDA059669R1 E3 W FP is a three-pole SACE Emax fixed part for withdrawable E3 air circuit breakers, rated at 3200 A and 690 V AC with rear flat horizontal upper and lower terminals.

SKU: 1SDA059669R1Alt SKU: NEW E3 FP 3P RHTMPN: 1SDA059669R1
Price
List Price £3,213.57 ex VAT
Your Price (ex VAT) Save 25%
£2,410.18 25% OFF
You save £803.39 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,410.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,410.18

Why Choose the ABB E3 W FP 3p HR-HR New Fixed Part?

The ABB E3 W FP 3p HR-HR new, order code 1SDA059669R1, is a robust SACE Emax E3 fixed part for withdrawable air circuit breakers, designed for high-current industrial low-voltage power distribution systems. Also identified as NEW E3 FP 3P RHT, this fixed part provides the stationary mechanical and electrical interface for a compatible ABB E3 withdrawable circuit breaker within a switchboard.

This version features a three-pole configuration and rear flat horizontal terminals at both the upper and lower connections. The withdrawable fixed-part arrangement supports efficient circuit breaker installation, isolation, servicing and replacement while the fixed assembly remains installed within the switchgear.

With a rated uninterrupted current of 3200 A and a rated voltage of 690 V AC, the 1SDA059669R1 is engineered for substantial power distribution duties. Its E3 frame, IEC design and heavy-duty construction make it suitable for industrial switchboards, main distribution assemblies and other demanding electrical infrastructure.

Key Advantages

  • Genuine ABB SACE Emax E3 fixed part for compatible withdrawable air circuit breakers.
  • 3200 A rated uninterrupted current for high-current power distribution.
  • 690 V AC rated voltage for industrial low-voltage systems.
  • Three-pole configuration suitable for three-phase distribution networks.
  • Upper and lower rear flat horizontal terminals support practical busbar connection arrangements.
  • Withdrawable architecture facilitates circuit breaker servicing, inspection and replacement.

Key Features

  • ABB SACE Emax / New Emax E3 series.
  • WFP fixed-part version.
  • 3-pole configuration.
  • 3200 A rated uninterrupted current (Iu).
  • 690 V AC rated voltage (Ur).
  • Rear flat horizontal upper terminals.
  • Rear flat horizontal lower terminals.
  • Designed for withdrawable E3 circuit breakers.
  • Designed in accordance with applicable IEC requirements.

Reliable Circuit Breaker Integration for Industrial Switchgear

A fixed part forms the permanently installed section of a withdrawable air circuit breaker arrangement, providing the electrical connection and mechanical interface between the removable breaker and the switchboard. This architecture allows the compatible circuit breaker to be withdrawn for inspection, maintenance or replacement without removing the fixed assembly from the distribution panel.

The ABB 1SDA059669R1 combines a substantial 3200 A current capability with an E3 frame and horizontal rear connections, making it well suited to high-current three-phase switchboards. Its SACE Emax design provides a robust foundation for serviceable and dependable industrial power distribution assemblies.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main power distribution assemblies.
  • High-current three-phase distribution systems.
  • Withdrawable air circuit breaker installations.
  • Manufacturing and process plant electrical distribution.
  • Infrastructure and commercial power distribution systems.
  • OEM switchgear and panel-building applications.

Technical Specifications

Series SACE Emax / New Emax
Alternative designation NEW E3 FP 3P RHT
ABB order code 1SDA059669R1
Product type Fixed part for withdrawable air circuit breaker
Version WFP
Sub-type E3
Number of poles 3P
Rated uninterrupted current (Iu) 3200 A
Rated voltage (Ur) 690 V
Current type AC
Terminal arrangement Rear flat horizontal, upper and lower
Circuit-breaker type Withdrawable
Standards IEC
Dimensions (W × H × D) 432 × 461 × 396.5 mm
Net weight 37 kg
EAN 8015644620936
Product group 310513 – New Emax

Frequently Asked Questions

What is the ABB 1SDA059669R1 used for?

The ABB 1SDA059669R1 is a fixed part for a compatible SACE Emax E3 withdrawable air circuit breaker, providing its stationary mounting and electrical connection interface within a switchboard.

What is the current rating of the ABB 1SDA059669R1?

The fixed part has a rated uninterrupted current (Iu) of 3200 A, making it suitable for high-current industrial distribution applications.

What voltage is the ABB E3 W FP 3p HR-HR rated for?

The ABB 1SDA059669R1 has a rated voltage (Ur) of 690 V AC.

How many poles does the 1SDA059669R1 have?

This Emax E3 fixed part has a three-pole (3P) configuration for three-phase electrical distribution systems.

What terminal arrangement does the ABB E3 W FP 3p HR-HR use?

It uses rear flat horizontal terminals for both the upper and lower connections, corresponding to the HR-HR configuration.

Trusted by Industrial Electrical Professionals Worldwide

ABB SACE Emax equipment is widely specified for industrial power distribution systems where high-current capability, robust construction and serviceable withdrawable circuit breaker arrangements are required.