ABB E3N2500PR121/P-LSIG is a 2500 A three-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LSIG R2500 electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection.
£15,980.20
The ABB E3N2500PR121/P-LSIG is a high-performance 2500 A three-pole air circuit breaker moving part designed for reliable switching and comprehensive protection in demanding low-voltage power distribution systems. As part of the established ABB SACE Emax New Emax series, this E3N configuration combines a robust high-current breaker frame with the PR121/P-LSIG electronic overcurrent release.
The PR121/P-LSIG trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. These LSIG functions help protect cables, busbars, switchboards and connected equipment against overloads, short circuits and earth faults, making the breaker suitable for critical industrial and commercial distribution networks.
With a rated current of 2500 A, a three-pole withdrawable moving-part configuration and an E3N frame offering 65 kA short-circuit breaking capacity, ABB order code 1SDA056130R1 is designed for high-current switchboard applications. The assembly is fitted with four auxiliary contacts and circuit-breaker open/closed position indication for status signalling and control integration.
Air circuit breakers such as the ABB E3N2500 provide switching and overcurrent protection for high-current low-voltage distribution circuits. The electronic trip release monitors circuit conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect cables, busbars, switchboards and connected electrical equipment against damaging overloads and fault currents.
The PR121/P-LSIG release combines long-time, short-time, instantaneous and earth-fault protection in an electronic trip system. Together with the E3N frame's 65 kA short-circuit performance and service-friendly withdrawable construction, this makes the breaker moving part suitable for critical main distribution and high-current feeder applications.
| Series | SACE Emax / New Emax |
|---|---|
| ABB order code | 1SDA056130R1 |
| Extended product type | E3N2500PR121/P-LSIGIn=2500A3pWMP |
| Product type | Air circuit breaker moving part |
| Frame | E3N |
| Short-circuit performance level | N |
| Rated current | 2500 A |
| Rated operational current | 2500 A |
| Rated uninterrupted current | 2500 A |
| Number of poles | 3 |
| Current type | AC |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 12 kV |
| Rated ultimate short-circuit breaking capacity | 65 kA |
| Rated service short-circuit breaking capacity | 65 kA |
| Rated short-time withstand current | 65 kA for 1 s / 3 s |
| Execution | Withdrawable moving part (W MP) |
| Trip unit | PR121/P-LSIG |
| Release type | Electronic |
| Overcurrent release rating | R2500 |
| Protection functions | L, S, I and G |
| Overload release setting range | 1000–2500 A |
| Short-time short-circuit setting range | 2500–25,000 A |
| Instantaneous short-circuit setting range | 3750–37,500 A |
| Integrated earth-fault protection | Yes |
| Auxiliary contacts | 4 (2 NO + 2 NC) |
| Position indication | Circuit breaker open / closed |
| Motor operator | Optional |
| Protection rating | IP2X |
| Power loss | 350 W |
| Electrical durability | 8000 cycles at Ue ≤ 440 V; 7000 cycles at Ue 500–690 V |
| Mechanical durability | 20,000 cycles |
| Dimensions (W × H × D) | 432 × 461 × 396.5 mm |
| Net weight | 64 kg |
| EAN | 8015644574703 |
| Customs tariff number | 85362090 |
| Standard | IEC |
It is a 2500 A three-pole air circuit breaker moving part designed for switching and protecting high-current low-voltage AC power distribution circuits.
The PR121/P-LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
The E3N2500 has a rated ultimate and service short-circuit breaking capacity of 65 kA, together with a rated short-time withstand current of 65 kA.
ABB order code 1SDA056130R1 is a three-pole withdrawable moving part for a compatible SACE Emax E3N circuit-breaker installation.
Yes. This configuration is fitted with four auxiliary contacts, comprising two normally open and two normally closed contacts, together with circuit-breaker open/closed position indication.
ABB SACE Emax air circuit breakers are widely used in industrial and commercial low-voltage distribution systems, combining robust high-current switching technology with comprehensive electronic protection and service-friendly withdrawable configurations for demanding electrical installations.