Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA055102R1 TMG400-2000T54pInN=100%In is a 400 A four-pole thermal-magnetic trip unit with 2000 A magnetic protection and 100% neutral protection for compatible ABB SACE Tmax T5 moulded-case circuit breakers.
£1,093.42
The ABB 1SDA055102R1 is a genuine TMG thermal-magnetic trip unit for compatible ABB SACE Tmax T5 moulded-case circuit breakers. Identified as TMG400-2000T54pInN=100%In, it is a four-pole protection unit with a rated current of 400 A and an instantaneous magnetic protection setting of 2000 A.
The TMG trip unit combines thermal overload protection with magnetic short-circuit protection, providing essential protection functions for low-voltage distribution circuits. The four-pole configuration incorporates neutral-pole protection rated at 100% of the phase rated current, as indicated by the InN=100%In specification.
Designed specifically for the ABB SACE Tmax T5 platform, the 1SDA055102R1 provides a matched protection solution for compatible circuit-breaker assemblies. Its thermal-magnetic operating principle makes it suitable for industrial and commercial distribution systems requiring dependable overload and short-circuit protection without an electronic trip unit.
Thermal-magnetic trip units provide two complementary protection functions. The thermal element responds to sustained overcurrent conditions to provide overload protection, while the magnetic element responds rapidly to high fault currents associated with short circuits. This established protection principle provides dependable circuit protection without requiring electronic trip-unit functionality.
The ABB 1SDA055102R1 is configured for a rated current of 400 A with 2000 A magnetic protection and four-pole operation. Its 100% neutral protection means the neutral pole is protected at the same rated-current level as the phase conductors, making the unit suitable for compatible four-wire distribution applications requiring full neutral protection.
| Order code | 1SDA055102R1 |
|---|---|
| Product designation | TMG400-2000T54pInN=100%In |
| Product type | Thermal-magnetic trip unit |
| Trip unit | TMG |
| Rated current (In) | 400 A |
| Magnetic protection setting | 2000 A |
| Number of poles | 4 |
| Neutral protection | InN = 100% In |
| Protection functions | Thermal overload and magnetic short-circuit protection |
| Suitable for | Tmax T5 |
| Product family | SACE Tmax T |
| ABB product group | 310511-T-Max T4 - T8 |
The ABB 1SDA055102R1 is a TMG thermal-magnetic trip unit for compatible ABB SACE Tmax T5 moulded-case circuit breakers, providing overload and short-circuit protection.
The trip unit has a rated current of 400 A.
The TMG400-2000 configuration specifies a magnetic protection setting of 2000 A.
The 1SDA055102R1 is configured for a 4-pole Tmax T5 circuit breaker.
InN=100%In indicates that the neutral-pole protection is rated at 100% of the phase rated current, providing full-current protection for the neutral conductor in the compatible four-pole configuration.
ABB SACE Tmax circuit breakers and their dedicated protection units are used in industrial and commercial low-voltage distribution systems where dependable overload protection, short-circuit protection and correctly coordinated circuit-breaker components are essential.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.