ABB 1SDA055099R1 TMG 500-2500 T5 630 3p is a 500 A three-pole thermomagnetic trip unit for compatible SACE Tmax T5 630 circuit breakers with an adjustable 1250–2500 A instantaneous short-circuit setting for generator and electrical system protection.

SKU: 1SDA055099R1MPN: 1SDA055099R1
Price
List Price £1,457.89 ex VAT
Your Price (ex VAT) Save 25%
£1,093.42 25% OFF
You save £364.47 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,093.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,093.42

Why Choose the ABB TMG 500-2500 T5 630 3p?

The ABB 1SDA055099R1 is a genuine TMG thermomagnetic trip unit designed for compatible ABB SACE Tmax T5 630 moulded case circuit breakers. Identified by ABB as TMG 500-2500 T5 630 3p, this three-pole release combines thermal overload protection with magnetic short-circuit protection for demanding low-voltage electrical installations.

Designed for the ABB SACE Tmax T5 630 platform, the 1SDA055099R1 has a rated current of 500 A. Its instantaneous magnetic short-circuit release provides an adjustable setting range of 1250–2500 A, allowing the protection characteristics to be coordinated with the requirements of the connected circuit.

The TMG range is intended for generator protection and is suitable for compatible AC and DC applications. With its 3-pole configuration, the ABB 1SDA055099R1 provides a manufacturer-matched protection solution for generator switchboards, industrial power systems and other installations using compatible Tmax T5 630 circuit breakers.

Key Advantages

  • Genuine ABB SACE Tmax T5 protection accessory.
  • TMG thermomagnetic technology provides overload and short-circuit protection.
  • 500 A rated current for compatible Tmax T5 630 installations.
  • Adjustable instantaneous short-circuit setting from 1250–2500 A.
  • 3-pole configuration for three-phase systems.
  • Designed for generator protection applications.
  • Suitable for compatible AC and DC electrical systems.

Key Features

  • ABB SACE Tmax T5 630 trip-unit platform.
  • TMG thermomagnetic release.
  • 500 A rated current.
  • 1250–2500 A adjustable instantaneous short-circuit setting.
  • 3-pole configuration.
  • Thermal protection for sustained overload conditions.
  • Magnetic protection for high short-circuit currents.
  • Designed for compatible generator protection applications.
  • Suitable for compatible AC/DC circuits.
  • ABB order code 1SDA055099R1.
  • EAN 8015644562434.

Thermomagnetic Generator Protection for Tmax T5 630

A thermomagnetic trip unit combines two established protection principles within a single circuit-breaker release. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation when current reaches a high short-circuit level. This combination provides dependable protection without relying on electronic measurement for the fundamental overload and short-circuit functions.

The ABB 1SDA055099R1 provides a 500 A TMG release for compatible Tmax T5 630 circuit breakers. Its adjustable instantaneous magnetic setting of 1250–2500 A allows the short-circuit threshold to be coordinated with the electrical system, while the TMG design makes the unit particularly suitable for generator protection and related low-voltage distribution applications.

Typical Applications

  • Generator protection systems.
  • ABB SACE Tmax T5 630 moulded case circuit breakers.
  • Three-phase low-voltage electrical systems.
  • Generator switchboards and distribution panels.
  • Industrial power generation installations.
  • Commercial and industrial power distribution systems.
  • Compatible AC and DC circuit protection applications.

Technical Specifications

Series SACE Tmax T
Product group 310511-T-Max T4 - T8
Model / type TMG 500-2500 T5 630 3p
Order code 1SDA055099R1
Product type Thermomagnetic trip unit
Trip-unit type TMG
Compatible frame Tmax T5 630
Rated current 500 A
Instantaneous short-circuit trip range 1250–2500 A
Number of poles 3
Protection functions Overload and short-circuit protection
Application Generator and electrical system protection
Suitable current systems AC / DC
EAN 8015644562434
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA055099R1?

The ABB 1SDA055099R1 is a TMG thermomagnetic trip unit rated at 500 A for compatible three-pole ABB SACE Tmax T5 630 moulded case circuit breakers.

What is the short-circuit trip range of the ABB 1SDA055099R1?

The instantaneous magnetic short-circuit setting is adjustable from 1250–2500 A.

Which circuit breaker is the ABB 1SDA055099R1 designed for?

The trip unit is designed for compatible ABB SACE Tmax T5 630 moulded case circuit breakers and has a three-pole configuration.

What protection does the ABB TMG 500 trip unit provide?

The TMG release provides thermal overload protection and magnetic short-circuit protection, protecting compatible circuits against sustained overcurrent and high fault-current conditions.

Is the ABB 1SDA055099R1 suitable for generator protection?

Yes. The ABB TMG range is designed for generator protection, and the 1SDA055099R1 provides a 500 A three-pole configuration with an adjustable 1250–2500 A instantaneous magnetic setting.

Trusted ABB Generator Protection

ABB SACE Tmax thermomagnetic releases provide panel builders, electrical contractors and industrial users with purpose-designed overload and short-circuit protection for generator installations and demanding low-voltage power distribution systems.