1SDA054712R1 ABB PR222DS/PD-LSI 400 A Modbus T5 3P Electronic Trip Unit

1SDA054712R1 ABB PR222DS/PD-LSI 400 A Modbus T5 3P Electronic Trip Unit

ABB 1SDA054712R1 is a 400 A three-pole PR222DS/PD-LSI electronic trip unit for SACE Tmax T5 moulded-case circuit breakers with LSI protection and integrated Modbus RTU communication.

SKU: 1SDA054712R1Alt SKU: PR222DS/PD-LSIIN=4MPN: 1SDA054712R1
Price
List Price £4,014.11 ex VAT
Your Price (ex VAT) Save 25%
£3,010.58 25% OFF
You save £1,003.53 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,010.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,010.58

Why Choose the ABB 1SDA054712R1 PR222DS/PD-LSI 400 A Modbus T5 3P Electronic Trip Unit?

The ABB 1SDA054712R1 is a PR222DS/PD-LSI electronic trip unit designed for three-pole ABB SACE Tmax T5 moulded-case circuit breakers. Rated at 400 A, it combines electronic LSI protection with integrated Modbus RTU communication for intelligent low-voltage power distribution, monitoring and industrial automation applications.

The PR222DS/PD provides long-time overload (L), selective short-circuit (S) and instantaneous short-circuit (I) protection. These electronic protection functions enable the associated Tmax T5 circuit breaker to respond to different overcurrent conditions while supporting coordinated protection within industrial and commercial electrical distribution systems.

Integrated communication functionality enables the PR222DS/PD to exchange information over a Modbus RTU network using an RS-485 interface. This makes the 1SDA054712R1 particularly suitable for installations where circuit protection is combined with remote supervision, PLC integration and centralised power-management systems.

Key Advantages

  • Electronic trip unit specifically designed for ABB SACE Tmax T5 circuit breakers.
  • 400 A rated current for substantial low-voltage distribution loads.
  • LSI protection for overload, selective short-circuit and instantaneous short-circuit conditions.
  • Integrated Modbus RTU communication for networked monitoring and supervision.
  • Three-pole configuration for compatible three-phase electrical systems.
  • Supports integration of circuit protection into industrial automation and power-management networks.

Key Features

  • ABB PR222DS/PD-LSI electronic trip unit.
  • Designed for ABB SACE Tmax T5 moulded-case circuit breakers.
  • 400 A rated current (In).
  • Three-pole (3P) configuration.
  • L – long-time overload protection.
  • S – selective short-time short-circuit protection.
  • I – instantaneous short-circuit protection.
  • Integrated Modbus RTU communication functionality.
  • RS-485 serial communication interface.
  • Suitable for integration with compatible PLC, supervision and energy-management systems.

Electronic Protection with Integrated Modbus Communication

Electronic trip units monitor circuit current and initiate opening of the associated circuit breaker when configured protection thresholds are exceeded. The ABB PR222DS/PD-LSI combines long-time, selective short-time and instantaneous protection functions, helping protect conductors, switchgear and connected equipment against overload and short-circuit faults.

The integrated Modbus communication capability extends the trip unit beyond conventional protection by enabling connection to compatible industrial supervision and automation systems. This supports centralised monitoring and improved visibility of the electrical distribution network while retaining the dependable protection functions of the ABB SACE Tmax T5 platform.

Typical Applications

  • ABB SACE Tmax T5 moulded-case circuit breaker installations.
  • Industrial low-voltage distribution switchboards.
  • Three-phase feeder protection.
  • Modbus-connected electrical distribution systems.
  • PLC and supervisory monitoring networks.
  • Industrial power-management and automation systems.

Technical Specifications

Series SACE Tmax T5
ABB order code 1SDA054712R1
Product type Electronic circuit breaker trip unit
Trip unit PR222DS/PD-LSI
Suitable for ABB SACE Tmax T5 moulded-case circuit breaker
Rated current (In) 400 A
Number of poles 3
Protection technology Electronic
Protection functions LSI
Overload protection Long-time (L)
Selective short-circuit protection Short-time (S)
Instantaneous short-circuit protection Instantaneous (I)
Communication protocol Modbus RTU
Communication interface RS-485
Primary application Low-voltage power distribution protection and monitoring

Frequently Asked Questions

What is the ABB 1SDA054712R1?

The ABB 1SDA054712R1 is a PR222DS/PD-LSI electronic trip unit rated at 400 A for compatible three-pole ABB SACE Tmax T5 moulded-case circuit breakers.

What protection functions does the PR222DS/PD-LSI provide?

It provides LSI protection, comprising long-time overload protection (L), selective short-time short-circuit protection (S) and instantaneous short-circuit protection (I).

Does the ABB 1SDA054712R1 support Modbus communication?

Yes. The PR222DS/PD incorporates Modbus RTU communication for integration with compatible industrial monitoring, supervision and automation systems.

What is the rated current of the ABB 1SDA054712R1?

The electronic trip unit has a rated current (In) of 400 A.

How many poles is the ABB 1SDA054712R1 designed for?

The 1SDA054712R1 is designed for a three-pole (3P) ABB SACE Tmax T5 circuit breaker configuration.

Which circuit breaker family is the PR222DS/PD-LSI designed for?

This specific 400 A three-pole release is designed for compatible ABB SACE Tmax T5 moulded-case circuit breakers.

Trusted by Electrical and Automation Professionals Worldwide

ABB SACE Tmax electronic protection solutions are widely used in industrial and commercial power distribution systems where dependable circuit protection, communication and integration with modern electrical supervision systems are required.