1SDA054683R1 ABB MA 100-1400 T4 4-Pole Magnetic Trip Unit

1SDA054683R1 ABB MA 100-1400 T4 4-Pole Magnetic Trip Unit

ABB 1SDA054683R1 is a 100 A four-pole MA magnetic-only trip unit with an adjustable 600-1400 A instantaneous short-circuit threshold for compatible ABB SACE Tmax T4 circuit breaker assemblies.

SKU: 1SDA054683R1MPN: 1SDA054683R1
Price
List Price £438.86 ex VAT
Your Price (ex VAT) Save 25%
£329.15 25% OFF
You save £109.72 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £329.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£329.15

Why Choose the ABB 1SDA054683R1 MA 100-1400 Magnetic Trip Unit?

The ABB 1SDA054683R1 is an MA magnetic-only trip unit designed for compatible ABB SACE Tmax T4 moulded case circuit breakers. Rated at 100 A, this four-pole protection release provides instantaneous magnetic short-circuit protection for applications where overload protection is provided separately or is not required from the circuit breaker trip unit.

The MA release provides an adjustable instantaneous magnetic trip threshold (I3) of 600...1400 A. This allows the magnetic protection level to be selected to suit the characteristics of the protected circuit, making the release particularly useful in applications such as motor circuits where separate overload protection may be employed.

Designed for the ABB SACE Tmax T4 platform, the 1SDA054683R1 has a four-pole configuration and is suitable for compatible AC and DC applications. It is supplied as a magnetic protection release for integration with compatible Tmax T4 breaker hardware and is therefore a circuit breaker component rather than a complete standalone MCCB.

Key Advantages

  • Genuine ABB MA magnetic trip unit.
  • 100 A rated current for compatible ABB Tmax T4 circuit breakers.
  • Adjustable instantaneous magnetic trip threshold of 600...1400 A.
  • Provides rapid protection against high short-circuit currents.
  • Magnetic-only design suits applications where overload protection is provided separately.
  • Suitable for compatible AC and DC circuit breaker applications.
  • Four-pole configuration for compatible Tmax T4 assemblies.
  • Modular design for combination with suitable ABB Tmax T4 breaker hardware.

Key Features

  • ABB MA magnetic-only protection release.
  • 100 A rated current (In).
  • Four-pole configuration.
  • Instantaneous magnetic short-circuit protection.
  • 600...1400 A adjustable instantaneous magnetic threshold (I3).
  • Magnetic adjustment range of approximately 6...14 × In.
  • Suitable for compatible AC-DC applications.
  • Designed for compatible ABB SACE Tmax T4 MCCB hardware.
  • No integral thermal overload protection.
  • Suitable for circuits using separate overload protection where required.

Adjustable Magnetic Short-Circuit Protection for ABB Tmax T4

Unlike a thermomagnetic TMA release, the MA release is magnetic only. It is designed to respond rapidly when current reaches the selected instantaneous short-circuit threshold rather than providing time-dependent thermal overload protection. On the 1SDA054683R1, the I3 threshold is adjustable from 600 A to 1400 A, corresponding to approximately six to fourteen times the 100 A rated current.

This protection characteristic makes the MA release suitable for applications where overload protection is handled by another device, such as a dedicated motor overload relay. The 1SDA054683R1 is the 100 A four-pole MA release for compatible ABB Tmax T4 hardware; because it is not a complete MCCB, the final circuit breaker's voltage ratings and short-circuit breaking capacity depend on the compatible Tmax T4 breaking part with which it is assembled.

Typical Applications

  • ABB Tmax T4 moulded case circuit breaker assemblies.
  • Motor circuit short-circuit protection.
  • Circuits using separate overload relays or overload protection devices.
  • Industrial machinery and motor control systems.
  • Industrial low-voltage electrical distribution systems.
  • Four-pole electrical distribution applications.
  • Compatible AC and DC circuits requiring magnetic protection.
  • OEM switchgear and electrical control panel assemblies.

Technical Specifications

Series SACE Tmax T4
Product group 310511-T-Max T4 - T8
Order code 1SDA054683R1
EAN 8015644557973
Product type Magnetic-only trip unit / protection release
Release type MA
Rated current (In) 100 A
Instantaneous magnetic trip setting (I3) 600...1400 A
Magnetic setting range approximately 6...14 × In
Protection function Instantaneous magnetic short-circuit protection
Thermal overload protection No
Number of poles 4
Application AC-DC
Suitable for ABB SACE Tmax T4
Configuration Loose / configurable component
Standard IEC
Country of origin Italy
Product net weight 1 kg
Minimum order quantity 1 piece
Customs tariff number 85389099

Frequently Asked Questions

What is the ABB 1SDA054683R1?

The ABB 1SDA054683R1 is an MA magnetic-only trip unit rated at 100 A, with a four-pole configuration for compatible ABB SACE Tmax T4 circuit breaker assemblies.

What protection does the ABB MA 100-1400 trip unit provide?

The MA 100-1400 provides instantaneous magnetic short-circuit protection. It does not incorporate thermal overload protection, so separate overload protection should be provided where the application requires it.

What is the magnetic trip setting range of the ABB 1SDA054683R1?

The instantaneous magnetic trip threshold (I3) is adjustable from 600 A to 1400 A, equivalent to approximately six to fourteen times the release's 100 A rated current.

Can the ABB 1SDA054683R1 be used for motor protection?

The MA magnetic-only release is suitable for short-circuit protection in compatible motor circuits where overload protection is provided separately, for example by an appropriate motor overload protection device.

Is the ABB 1SDA054683R1 a complete circuit breaker?

No. The 1SDA054683R1 is a magnetic protection release rather than a complete circuit breaker. It must be combined with compatible ABB Tmax T4 breaker hardware to form the required MCCB assembly.

Trusted Magnetic Circuit Protection from ABB

ABB SACE Tmax MA releases provide dedicated instantaneous magnetic protection for applications requiring rapid short-circuit response, offering adjustable protection characteristics and modular integration with compatible Tmax circuit breaker hardware.