1SDA054678R1 ABB MA125-1750 T4 3p Magnetic Trip Unit

1SDA054678R1 ABB MA125-1750 T4 3p Magnetic Trip Unit

ABB 1SDA054678R1 MA125-1750 three-pole magnetic trip unit for compatible SACE Tmax T4 circuit breakers with a 125 A rated current and instantaneous magnetic short-circuit protection up to 1750 A.

SKU: 1SDA054678R1MPN: 1SDA054678R1
Price
List Price £2,902.85 ex VAT
Your Price (ex VAT) Save 25%
£2,177.14 25% OFF
You save £725.71 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,177.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,177.14

Why Choose the ABB MA125-1750 T4 3p?

The ABB MA125-1750 T4 3p, order code 1SDA054678R1, is a three-pole magnetic trip unit designed for compatible ABB SACE Tmax T4 moulded case circuit breakers. With a rated current of 125 A and adjustable instantaneous magnetic protection up to 1750 A, it is intended for applications where rapid short-circuit protection is required.

The MA magnetic release provides instantaneous protection rather than thermal overload protection. ABB's MA releases are particularly suited to motor protection applications where overload protection is provided separately, allowing the circuit breaker and magnetic release to provide high-speed protection against short-circuit faults.

This version is designed for three-pole Tmax T4 circuit breakers and provides an adjustable magnetic threshold associated with the MA125-1750 rating. Its modular design makes it suitable as a replacement or configuration component for compatible ABB Tmax T4 circuit breaker assemblies.

Key Advantages

  • Genuine ABB SACE Tmax T4 magnetic trip unit.
  • 125 A rated current for compatible T4 circuit breakers.
  • Adjustable instantaneous magnetic protection up to 1750 A.
  • Three-pole configuration for three-phase applications.
  • Magnetic-only protection provides rapid response to short-circuit faults.
  • Well suited to motor protection applications with separate overload protection.
  • Modular ABB Tmax construction supports circuit breaker configuration and replacement requirements.

Key Features

  • ABB SACE Tmax T4 series.
  • MA125-1750 magnetic release.
  • 125 A rated current.
  • Three-pole configuration.
  • Instantaneous magnetic short-circuit protection.
  • 1750 A maximum magnetic threshold.
  • Designed for compatible ABB Tmax T4 circuit breakers.
  • Suitable for motor circuit protection when coordinated with separate overload protection.
  • No thermal overload protection incorporated in the MA release.

Magnetic Protection for Motor Circuits

Motor circuits commonly require separate protection against overloads and short circuits. The ABB MA magnetic release is designed to provide the short-circuit element of this protection arrangement, responding rapidly when current rises to the selected instantaneous magnetic threshold.

Because the MA release does not incorporate thermal overload protection, it should be coordinated with appropriate external motor overload protection where required. This arrangement allows the magnetic threshold to accommodate normal motor starting currents while still providing rapid interruption of severe short-circuit faults.

Typical Applications

  • Three-phase motor protection circuits.
  • Industrial motor control centres.
  • Manufacturing machinery and production equipment.
  • Pumps, fans and compressor systems.
  • Conveyor and material handling equipment.
  • Industrial control panels and switchboards.
  • Replacement or configuration of compatible ABB Tmax T4 circuit breakers.

Technical Specifications

Series SACE Tmax T4
Order code / MPN 1SDA054678R1
Product group Tmax T4 - T8
Product type Magnetic trip unit / magnetic release
Trip unit MA
Rated current 125 A
Maximum magnetic threshold 1750 A
Number of poles 3
Protection function Instantaneous magnetic short-circuit protection
Thermal overload protection Not included
Compatible circuit breaker family ABB SACE Tmax T4

Frequently Asked Questions

What is the ABB 1SDA054678R1?

The ABB 1SDA054678R1 is an MA125-1750 three-pole magnetic trip unit designed for compatible ABB SACE Tmax T4 moulded case circuit breakers.

What is the rated current of the ABB MA125-1750?

The MA125-1750 trip unit has a rated current of 125 A.

What is the magnetic protection rating of the MA125-1750?

The MA125-1750 provides adjustable instantaneous magnetic short-circuit protection with a maximum magnetic threshold of 1750 A.

Does the ABB MA125-1750 provide overload protection?

No. The MA release provides instantaneous magnetic short-circuit protection and does not incorporate thermal overload protection, so suitable separate overload protection should be used where the application requires it.

What circuit breakers are compatible with ABB 1SDA054678R1?

The 1SDA054678R1 is designed for compatible three-pole ABB SACE Tmax T4 moulded case circuit breaker configurations.

Trusted ABB Motor Circuit Protection

ABB SACE Tmax circuit protection components provide flexible solutions for industrial power distribution and motor applications, with MA magnetic releases enabling dedicated short-circuit protection as part of a coordinated motor protection system.