OT160GT03P ABB 160 A 3-Pole Door-Mounted Switch-Disconnector

OT160GT03P ABB 160 A 3-Pole Door-Mounted Switch-Disconnector

ABB OT160GT03P is a 160 A 3-pole door-mounted switch-disconnector supplied with an IP65 external handle, shaft and mounting kit for industrial load switching and electrical isolation.

SKU: OT160GT03PAlt SKU: 1SCA135141R1001MPN: OT160GT03P
Price
List Price £331.17 ex VAT
Your Price (ex VAT) Save 35%
£215.26 35% OFF
You save £115.91 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £215.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£215.26

Why Choose the ABB OT160GT03P 160 A 3-Pole Door-Mounted Switch-Disconnector?

The ABB OT160GT03P is a compact, high-performance 160 A 3-pole switch-disconnector designed for dependable load switching and electrical isolation in industrial low-voltage systems. Part of the ABB OT160G switch-disconnector range, it provides strong IEC switching performance together with UL/CSA ratings for machinery, switchboards and power distribution applications.

This OT160GT P-version is specifically designed for door mounting and is supplied with an OHB65J6 black external handle, OXP6X50 shaft and OHZX6 door-mounting kit. The external handle provides IP65 protection, while the switch uses protected clamp terminals for secure connection of the main power conductors.

The OT160GT03P provides 160 A AC-22A and AC-23A operational current at 690 V AC, with an AC-23A operational power rating of 132 kW at 690 V AC. It is also rated at 100 A UL 98 Listed and 125 A UL 98 Recognized at 600 V, supporting industrial equipment designed for IEC and North American markets.

Key Advantages

  • 160 A 3-pole switch-disconnector for industrial switching and isolation.
  • 160 A AC-22A and AC-23A rating at 690 V AC.
  • Door-mounted construction for direct integration into electrical enclosures.
  • Supplied with black IP65 external handle, shaft and door-mounting kit.
  • Protected clamp terminals accommodate copper conductors from 10–70 mm².
  • Designed for applications to IEC 60947-3, UL 98 and CSA C22.2 No. 4.

Key Features

  • ABB OT160G switch-disconnector series.
  • 160 A conventional free-air thermal current.
  • 3-pole switching configuration.
  • 160 A AC-21A, AC-22A and AC-23A at 380–415 V AC.
  • 160 A AC-21A, AC-22A and AC-23A at 690 V AC.
  • 75 kW AC-23A operational power at 400–415 V AC.
  • 132 kW AC-23A operational power at 690 V AC.
  • 1000 V rated operational and insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Front and side operation possible with the supplied external handle and shaft.

Reliable Door-Mounted Switching and Isolation

The ABB OT160GT03P provides dependable three-phase load switching and electrical isolation with 160 A AC-23A capability throughout the 380–690 V AC range. Its AC-23A performance makes it suitable for demanding industrial loads, while its three-pole configuration simultaneously switches all three phase conductors.

The P-version provides a complete door-operating arrangement with the OHB65J6 external handle, OXP6X50 shaft and OHZX6 mounting kit. Combined with protected main terminals and an IP65 external handle, this configuration is particularly well suited to industrial machinery panels and electrical enclosures requiring externally accessible switching and isolation.

Typical Applications

  • Industrial machinery main switching and isolation.
  • Door-mounted electrical disconnect applications.
  • Three-phase motor and inductive-load circuits.
  • Industrial switchboards and distribution panels.
  • Manufacturing and process equipment.
  • OEM machinery requiring IEC and UL/CSA switching solutions.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole
Device Type Switch Disconnector
Current 160 A
Power 75 kW
Product Series ABB OT
Series OT160G
ABB order code 1SCA135141R1001
ABB product group 311027-OT Switches
Product type Switch-disconnector
Number of poles 3
Conventional free-air thermal current 160 A
Fully enclosed thermal current 160 A
Rated operational current AC-21A at 380–415 V AC 160 A
Rated operational current AC-21A at 500 V AC 160 A
Rated operational current AC-21A at 690 V AC 160 A
Rated operational current AC-22A at 380–415 V AC 160 A
Rated operational current AC-22A at 500 V AC 160 A
Rated operational current AC-22A at 690 V AC 160 A
Rated operational current AC-23A at 380–415 V AC 160 A
Rated operational current AC-23A at 500 V AC 160 A
Rated operational current AC-23A at 690 V AC 160 A
Rated operational power AC-23A at 400–415 V AC 75 kW
Rated operational power AC-23A at 500 V AC 90 kW
Rated operational power AC-23A at 690 V AC 132 kW
Rated operational voltage 1000 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated short-time withstand current (Icw) 4 kA for 1 s
Rated short-circuit making capacity at 690 V 12 kA
UL 98 Listed rating at 600 V 100 A
UL 98 Recognized rating at 600 V 125 A
Operating mechanism Mechanism at left end of switch
Operating mode Front and side operation
Mounting type Door mounted
Terminal type Protected clamp / screw terminals
Cable cross-section 10–70 mm² Cu
External handle OHB65J6 black handle included
Shaft OXP6X50 included
Door-mounting kit OHZX6 included
External handle protection IP65
Mechanical durability 20,000 operations
Standards IEC 60947-3, UL 98, CSA C22.2 No. 4

Frequently Asked Questions

What is the ABB OT160GT03P used for?

The ABB OT160GT03P is a 160 A 3-pole door-mounted switch-disconnector designed for load switching and electrical isolation in industrial machinery, switchboards and low-voltage power distribution systems.

What is the current rating of the ABB OT160GT03P?

The OT160GT03P has a conventional free-air thermal current of 160 A and is rated at 160 A for AC-21A, AC-22A and AC-23A duties at 690 V AC.

What is included with the ABB OT160GT03P?

The P-version includes an OHB65J6 black external handle, OXP6X50 shaft and OHZX6 door-mounting kit.

What protection rating does the OT160GT03P handle provide?

The supplied external operating handle provides IP65 protection, making it suitable for demanding industrial enclosure applications.

What conductor sizes can be connected to the OT160GT03P?

The protected clamp terminals accommodate copper conductors with cross-sectional areas from 10–70 mm².

Does the ABB OT160GT03P have UL ratings?

Yes. The OT160GT03P is rated at 100 A UL 98 Listed and 125 A UL 98 Recognized at 600 V, in addition to its IEC ratings.

Trusted by Industrial Electrical Professionals Worldwide

ABB OT switch-disconnectors are widely used in industrial machinery, switchboards and power distribution systems where dependable load switching, positive electrical isolation and internationally recognised electrical performance are required.