ABB OT1600E12P is a 1600 A 3-pole front-operated switch-disconnector with a mechanism-between-the-poles configuration, supplied with a shaft, pistol handle and terminal bolt kit for high-current industrial electrical isolation.
£2,051.52
The ABB OT1600E12P is a heavy-duty 1600 A 3-pole isolator switch / switch-disconnector designed for reliable switching and isolation of high-current low-voltage electrical circuits. As part of the proven ABB OT switch-disconnector series, it is engineered for industrial power distribution, switchboards and machinery installations requiring dependable three-phase circuit isolation.
The OT1600E12P uses ABB's mechanism-between-the-poles configuration and is designed for front operation and base mounting. This complete P-version is supplied with an OXP12X280 shaft, OHB274J12 black ON-OFF pistol handle and M12X60 terminal bolt kit, providing the principal operating accessories required for integration into a suitable electrical assembly.
With an open-air thermal current of 1600 A and a 3-pole configuration, the OT1600E12P is suitable for substantial industrial distribution duties. At 380–415 V AC it is rated at 1600 A for AC-21A and AC-22A duties and 1250 A for AC-23A duty, with an AC-23A operational power rating of 710 kW at 400–415 V AC.
Switch-disconnectors provide a defined means of switching and electrically isolating circuits so downstream equipment can be separated from its power source for operation, servicing and maintenance. The ABB OT1600E12P combines a substantial 1600 A thermal-current rating with a robust three-pole mechanism for demanding industrial power distribution systems.
Its mechanism-between-the-poles arrangement provides a practical configuration for high-current switchboard designs, while the supplied shaft, pistol handle and terminal bolt kit support straightforward integration into suitable electrical assemblies. High AC-21A, AC-22A and AC-23A ratings make the OT1600E12P suitable for a broad range of industrial switching and isolation duties.
Tick the specs you need, then view products that match.
| Poles | 3-pole | |
|---|---|---|
| Device Type | Switch Disconnector | |
| Current | 1600 A | |
| Power | 710 kW | |
| Product Series | ABB OT | |
| Series | OT Switch-Disconnectors | |
| ABB order code | 1SCA022871R5950 | |
| ABB product group | 311027-OT Switches | |
| Product type | Isolator switch / switch-disconnector | |
| Open-air thermal current | 1600 A | |
| Number of poles | 3 | |
| Rated operational voltage | 1000 V | |
| Rated insulation voltage (Ui) | 1000 V | |
| Rated impulse withstand voltage (Uimp) | 12 kV | |
| Rated operational current AC-21A at 380–415 V AC | 1600 A | |
| Rated operational current AC-21A at 500 V AC | 1600 A | |
| Rated operational current AC-21A at 690 V AC | 1600 A | |
| Rated operational current AC-22A at 380–415 V AC | 1600 A | |
| Rated operational current AC-22A at 500 V AC | 1600 A | |
| Rated operational current AC-22A at 690 V AC | 1600 A | |
| Rated operational current AC-23A at 380–415 V AC | 1250 A | |
| Rated operational current AC-23A at 500 V AC | 1250 A | |
| Rated operational current AC-23A at 690 V AC | 1250 A | |
| Rated operational power AC-23A at 400–415 V AC | 710 kW | |
| Rated operational power AC-23A at 500 V AC | 900 kW | |
| Rated operational power AC-23A at 690 V AC | 1200 kW | |
| Rated short-time withstand current (Icw) | 50 kA for 1 s | |
| Operating mechanism | Mechanism between the poles | |
| Operating method | Front operated | |
| Mounting type | Base mounting | |
| Terminal type | Lug terminals | |
| Included shaft | OXP12X280 | |
| Included handle | OHB274J12 black pistol handle | |
| Included terminal bolt kit | M12X60 | |
| Standard | IEC 60947-3 | |
| Weight | 19 kg |
The ABB OT1600E12P is a 1600 A 3-pole isolator switch / switch-disconnector designed for switching and isolating high-current electrical circuits in industrial power distribution and switchboard applications.
The OT1600E12P has an open-air thermal current of 1600 A. At 380–415 V AC it is rated at 1600 A for AC-21A and AC-22A duties and 1250 A for AC-23A duty.
The OT1600E12P has a 3-pole configuration designed for simultaneous switching and isolation of three-phase electrical circuits.
The OT1600E12P uses ABB's mechanism-between-the-poles configuration and is designed for front operation and base mounting.
Yes. The OT1600E12P is supplied with an OXP12X280 shaft, OHB274J12 black pistol handle and M12X60 terminal bolt kit as standard.
The ABB OT1600E12P has a rated operational voltage of 1000 V and a rated insulation voltage of 1000 V.
ABB OT switch-disconnectors are widely used in industrial power distribution, switchgear and machinery installations where dependable high-current switching, positive electrical isolation and robust electrical performance are required.