SP2-30K750V Mersen Type 2 1P 690V Replacement Cartridge

SP2-30K750V Mersen Type 2 1P 690V Replacement Cartridge

Mersen 83020007 SP2-30K750V Type 2 surge protection replacement cartridge with 30 kA discharge rating and 750 V AC maximum continuous operating voltage for compatible Surge-Trap devices.

SKU: 83020007Alt SKU: SP2-30K750VMPN: 83020007
Price
List Price £38.94 ex VAT
Your Price (ex VAT) Save 25%
£29.21 25% OFF
You save £9.74 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £29.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£29.21

Why Choose the Mersen 83020007 Type 2 Replacement Cartridge?

The Mersen 83020007, also known as SP2-30K750V, is a reliable Type 2 surge protection replacement cartridge designed for compatible Mersen Surge-Trap pluggable surge protection devices. It helps protect electrical installations against transient overvoltages caused by switching operations, indirect lightning effects and power network disturbances.

As part of the Mersen Surge-Trap STP T2 series, this replacement cartridge is suitable for low-voltage distribution systems where coordinated surge protection is required. Its plug-in design allows fast replacement during maintenance, helping reduce downtime while restoring protection to the surge protection assembly.

With a 30 kA discharge rating and 750 V AC maximum continuous operating voltage, the Mersen 83020007 is a practical choice for Type 2 SPD applications on higher-voltage low-voltage electrical systems.

Key Advantages

  • Type 2 / Class II surge protection replacement cartridge for compatible Mersen Surge-Trap devices.
  • 30 kA surge discharge capability for reliable transient overvoltage protection.
  • 750 V AC maximum continuous operating voltage for suitable high-voltage low-voltage systems.
  • 1 pole configuration for line-to-neutral surge protection applications.
  • Plug-in cartridge format supports quick replacement and reduced maintenance time.
  • Suitable for distribution panels, switchboards and industrial electrical systems.

Key Features

  • Mersen Surge-Trap STP T2 series.
  • Type 2 / Class II surge protection.
  • Replacement cartridge format.
  • 1 pole configuration.
  • 690 V AC nominal voltage.
  • 750 V AC maximum continuous operating voltage.
  • 30 kA discharge rating.
  • Designed for compatible DIN rail SPD assemblies.

Reliable Type 2 Surge Protection for Distribution Systems

Type 2 surge protection devices are commonly installed in distribution boards and sub-distribution panels to limit transient overvoltages before they reach connected electrical equipment. They are often used as the second stage of protection where Type 1 devices are installed upstream, or as the first stage in installations without direct lightning exposure.

The Mersen 83020007 replacement cartridge enables maintenance teams to restore surge protection quickly without replacing the complete SPD base. This makes it suitable for panel builders, electrical contractors and facilities engineers maintaining commercial and industrial electrical systems.

Typical Applications

  • 690 V low-voltage electrical systems.
  • Industrial electrical distribution boards.
  • Commercial building services panels.
  • Control panels and switchboards.
  • Sub-distribution surge protection systems.
  • Maintenance replacement for compatible Mersen Surge-Trap devices.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 750 V
Phase Single Phase
Poles 1-pole
Device Type Replacement cartridge
SPD Type Type 2
Manufacturer Mersen
Series Surge-Trap STP T2
Model SP2-30K750V
Manufacturer part number 83020007
Product type Surge protection replacement cartridge
SPD classification Type 2 / Class II
Number of poles 1 pole
Nominal voltage 690 V AC
Maximum continuous operating voltage (Uc) 750 V AC
Discharge rating 30 kA
Protection rating IP20
Mounting Pluggable replacement cartridge
Compatible installation DIN rail SPD assembly
EAN 8435297850229

Frequently Asked Questions

What is the Mersen 83020007 used for?

The Mersen 83020007 is a Type 2 replacement cartridge for compatible Mersen Surge-Trap surge protection devices used in low-voltage electrical distribution systems.

What is the alternative product code?

The alternative product code for Mersen 83020007 is SP2-30K750V.

What voltage is this cartridge rated for?

This replacement cartridge is designed for 690 V AC nominal systems and has a 750 V AC maximum continuous operating voltage.

What surge protection type does this cartridge provide?

The Mersen 83020007 is designed for Type 2 / Class II surge protection assemblies.

Where is this replacement cartridge typically installed?

It is typically installed in compatible Mersen Surge-Trap pluggable SPD assemblies within distribution boards, switchboards and control panels.

Trusted by Electrical Engineers Worldwide

Mersen Surge-Trap surge protection products are widely used by electrical engineers, panel builders and contractors to protect commercial and industrial electrical installations from damaging transient overvoltages.