SP12-25K275V Mersen Type 1+2 1P 230V Replacement Cartridge

SP12-25K275V Mersen Type 1+2 1P 230V Replacement Cartridge

Mersen 83120007 SP12-25K275V Type 1+2 1 pole surge protection device with 25 kA lightning impulse current, 100 kA maximum discharge current and 275 V AC maximum continuous operating voltage.

SKU: 83120007Alt SKU: SP12-25K275VMPN: 83120007
Price
List Price £121.41 ex VAT
Your Price (ex VAT) Save 25%
£91.06 25% OFF
You save £30.35 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £91.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£91.06

Why Choose the Mersen 83120007 Surge-Trap Surge Protection Device?

The Mersen 83120007, also known as SP12-25K275V, is a high-performance Type 1+2 surge protection device designed to protect electrical installations from lightning currents and transient overvoltages. It is suitable for use in industrial, commercial and power distribution systems where reliable incoming surge protection is required.

As part of the Mersen Surge-Trap STPT12 25 kA series, this pluggable SPD is engineered for installation at the origin of an electrical system. It helps discharge high-energy surge currents while limiting voltage spikes that could otherwise damage downstream equipment, control panels, automation systems and sensitive electronics.

With a 25 kA lightning impulse current rating, 100 kA maximum discharge current and 275 V AC maximum continuous operating voltage, the Mersen 83120007 is a robust 1 pole Type 1+2 SPD for 230 V networks and coordinated surge protection applications.

Key Advantages

  • Type 1+2 / Class I+II surge protection device for incoming electrical protection.
  • 25 kA lightning impulse current rating for high-energy surge discharge.
  • 100 kA maximum discharge current for robust protection performance.
  • 275 V AC maximum continuous operating voltage for 230 V electrical systems.
  • Pluggable cartridge design supports fast maintenance and replacement.
  • Suitable for industrial switchboards, distribution boards and control panels.

Key Features

  • Mersen Surge-Trap STPT12 series.
  • Type 1+2 / Class I+II SPD.
  • 1 pole configuration.
  • 230 V nominal voltage.
  • 275 V AC maximum continuous operating voltage.
  • 25 kA lightning impulse current.
  • 25 kA nominal discharge current.
  • 100 kA maximum discharge current.

Reliable Surge Protection for Electrical Distribution Systems

Type 1+2 surge protection devices are commonly installed at the incoming supply of an electrical installation to discharge lightning currents and reduce the risk of damaging transient overvoltages. They are especially important for sites with external lightning protection systems or increased exposure to atmospheric surge events.

The Mersen 83120007 supports dependable protection for connected equipment while providing a practical pluggable design for inspection and maintenance. This makes it suitable for panel builders, electrical contractors and facilities teams responsible for protecting critical power distribution infrastructure.

Typical Applications

  • Main incoming electrical distribution boards.
  • Industrial switchboards and control panels.
  • Commercial building electrical installations.
  • Facilities with external lightning protection systems.
  • Power distribution and automation systems.
  • DIN rail surge protection assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Impulse Current Iimp (kA) 25 kA
Voltage 275 V
Phase Single Phase
Poles 1-pole
Device Type Replacement cartridge
SPD Type Type 1+2
Nominal Discharge Current (In) 25 kA
Manufacturer Mersen
Series Surge-Trap STPT12 25
Model SP12-25K275V
Manufacturer part number 83120007
Product type Surge protection device
SPD classification Type 1+2 / Class I+II
Number of poles 1 pole
Nominal voltage 230 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Lightning impulse current (Iimp) 25 kA
Nominal discharge current (In) 25 kA
Maximum discharge current (Imax) 100 kA
Protection rating IP20
Mounting type DIN rail
Format Pluggable surge protection device

Frequently Asked Questions

What is the Mersen 83120007 used for?

The Mersen 83120007 is a Type 1+2 surge protection device used to protect electrical distribution systems from lightning currents and transient overvoltages.

What is the alternative product code?

The alternative product code for Mersen 83120007 is SP12-25K275V.

What voltage is the Mersen 83120007 rated for?

This surge protection device is designed for 230 V AC nominal systems and has a 275 V AC maximum continuous operating voltage.

What surge protection type does this device provide?

The Mersen 83120007 provides Type 1+2 / Class I+II surge protection with a 25 kA lightning impulse current rating.

Where is this surge protection device typically installed?

It is typically installed on DIN rail inside incoming distribution boards, industrial switchboards and control panels where coordinated surge protection is required.

Trusted by Electrical Engineers Worldwide

Mersen Surge-Trap surge protection devices are widely used by panel builders, electrical contractors and maintenance engineers to protect industrial and commercial electrical installations from lightning-related surge events and transient overvoltages.