Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Lovato SG2C4PA275R is a compact 4P Type 2 surge protection device with replaceable plug-in cartridges, 20 kA rated discharge current per pole, 40 kA maximum discharge current, 275 V AC maximum continuous operating voltage and remote status monitoring for three-phase AC electrical systems.
£121.76
The Lovato SG2C4PA275R is a compact and reliable Type 2 surge protection device (SPD) designed to protect low-voltage three-phase AC electrical installations against transient overvoltages caused by indirect lightning effects, induced surges and electrical switching operations. As part of the Lovato Electric SG2C series, it combines high surge discharge capability with replaceable plug-in cartridges in a space-saving DIN rail format.
Designed with a 4P configuration, the SG2C4PA275R provides a rated discharge current In of 20 kA per pole and a maximum discharge current Imax of 40 kA. Its voltage protection level Up of less than 1.5 kV helps limit potentially damaging transient voltages reaching downstream electrical and electronic equipment.
The SG2C4PA275R is suitable for 230/400 V AC systems and has a maximum continuous operating voltage Uc of 275 V AC. It also incorporates thermal protection, frontal operating/end-of-life indication and a remote contact, allowing SPD status to be monitored locally or remotely within electrical control and building management systems.
Type 2 surge protection devices such as the Lovato SG2C4PA275R divert transient surge currents away from sensitive electrical equipment while limiting the voltage appearing across the protected installation. They are designed to protect low-voltage power systems against transient overvoltages associated with indirect lightning effects and switching events.
The SG2C series combines high discharge capability with compact construction, replaceable plug-in cartridges, thermal protection and clear status indication. The SG2C4PA275R additionally provides remote status signalling, making it well suited to distribution boards where both efficient use of DIN rail space and external monitoring of surge protection status are required.
Tick the specs you need, then view products that match.
| Device Type | Surge protection device | |
|---|---|---|
| SPD Type | Type 2 | |
| Remote Signal | Yes | |
| HS Code | 85365080 | |
| Manufacturer | Lovato Electric | |
| Series | SG2C | |
| Model | SG2C4PA275R | |
| Product type | Surge protection device (SPD) | |
| SPD type / class | Type 2 | |
| Application | AC power lines | |
| Operating voltage type | AC | |
| Pole configuration | 4P | |
| Number of DIN modules | 2 | |
| Rated system voltage | 230/400 V AC | |
| Maximum continuous operating voltage Uc | 275 V AC | |
| Rated discharge current In (8/20 µs) | 20 kA per pole | |
| Maximum discharge current Imax (8/20 µs) | 40 kA | |
| Voltage protection level Up | <1.5 kV | |
| Open-circuit voltage Uoc (1.2/50 µs) | 6 kV | |
| Open-circuit current Icw (8/20 µs) | 3 kA | |
| Response time | <25 ns | |
| Short-circuit current rating Isccr | 25 kA | |
| Residual current rating | 5 µA | |
| Thermal protection | Yes | |
| Status indication | Frontal operating / end-of-life indication | |
| Remote status output | Yes | |
| Cartridge type | Plug-in / replaceable | |
| Mounting type | DIN rail | |
| Maximum flexible conductor section | 4 mm² (L, N) / 25 mm² (PE) | |
| Maximum rigid conductor section | 6 mm² (L, N) / 35 mm² (PE) | |
| Protection rating | IP20 | |
| Operating temperature | -40 to +85 °C | |
| Maximum altitude | 2,000 m | |
| Weight | 527 g | |
| EAN | 8013975318553 | |
| ETIM classification | EC000941 | |
| Standards | IEC/EN/BS 61643-11 |
The SG2C4PA275R is a Type 2 surge protection device used to protect three-phase AC electrical installations and connected equipment against transient overvoltages caused by indirect lightning effects and electrical switching events.
The device has a rated discharge current In (8/20 µs) of 20 kA per pole.
The SG2C4PA275R has a maximum discharge current Imax (8/20 µs) of 40 kA.
Yes. The SG2C4PA275R includes a remote status contact for external monitoring, together with frontal operating and end-of-life indication.
Yes. The SG2C4PA275R uses replaceable plug-in cartridges, allowing surge protection elements to be replaced without replacing the complete DIN rail base assembly.
Lovato Electric SG2C surge protection devices provide dependable Type 2 protection for low-voltage AC distribution systems, combining high surge discharge capability with compact construction, replaceable cartridges and practical local and remote status monitoring.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.