Mersen Surge Protector Type 2 SPD 2 Pole 120 Volt 20KA TNS

Mersen Surge Protector Type 2 SPD 2 Pole 120 Volt 20KA TNS

Mersen STPT2-40K150V-2P Type 2 surge protection device with 40 kA maximum discharge current, 150 V AC Uc, 120 V AC 1Ph+N 2+0 TNS configuration and pluggable DIN rail mounting.

SKU: 83020120Alt SKU: STPT2-40K150V-2PMPN: 83020120
Price
List Price £74.78 ex VAT
Your Price (ex VAT) Save 25%
£56.09 25% OFF
You save £18.70 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £56.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£56.09

Why Choose the Mersen 83020120 Surge Protection Device?

The Mersen 83020120 is a compact and reliable Type 2 surge protection device (SPD) designed to safeguard low voltage electrical installations from transient overvoltages caused by switching operations, utility disturbances and indirect lightning strikes. As part of the proven Mersen Surge-Trap® Pluggable STPT2 Series, it provides dependable protection for commercial, industrial and automation environments.

The STPT2-40K150V-2P is designed for 120 V AC single phase TNS (1Ph+N) electrical systems and delivers a 40 kA maximum discharge current (Imax) together with a 20 kA nominal discharge current (In). Its 2+0 TNS configuration protects both line and neutral conductors, helping safeguard downstream electrical equipment from damaging voltage surges.

With a 150 V AC maximum continuous operating voltage (Uc), compact 2 pole, 2 module pluggable construction and DIN rail mounting, the Mersen 83020120 is ideal for protecting switchboards, distribution panels, industrial control panels and sensitive electronic equipment.

Key Advantages

  • Compact Type 2 surge protection device for low voltage installations.
  • 40 kA maximum discharge current (Imax).
  • 20 kA nominal discharge current (In).
  • 150 V AC maximum continuous operating voltage (Uc).
  • 2+0 TNS configuration for single phase systems.
  • Pluggable cartridge design for quick maintenance and replacement.

Key Features

  • Mersen Surge-Trap® Pluggable STPT2 Series.
  • Type 2 / Class II surge protection.
  • 40 kA Imax (8/20 μs).
  • 20 kA In (8/20 μs).
  • 120 V AC nominal operating voltage.
  • 150 V AC Uc.
  • 1Ph+N, 2+0 TNS configuration.
  • 2 pole, 2 module pluggable DIN rail design.

Reliable Protection Against Electrical Surges

Type 2 surge protection devices divert damaging transient overvoltages away from connected equipment, reducing the likelihood of equipment failure, production downtime and costly repairs. They form an essential part of modern low voltage electrical distribution systems.

The Mersen Surge-Trap® STPT2 Series combines high surge current capability with replaceable pluggable cartridges, offering dependable long term protection and simplified maintenance for industrial and commercial installations.

Typical Applications

  • Single phase 120 V TNS electrical systems.
  • Commercial distribution boards.
  • Industrial control panels.
  • PLC and automation systems.
  • Building electrical services.
  • Low voltage power distribution equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 120 V
Phase Single Phase
Poles 2-pole
Device Type Surge protection device
SPD Type Type 2
Earthing System TN-S
Nominal Discharge Current (In) 20 kA
Remote Signal No
Manufacturer Mersen
Series Surge-Trap® Pluggable STPT2 Series - 40 kA
Model STPT2-40K150V-2P
SKU 83020120
Product type Type 2 Surge Protection Device
SPD class Type 2 / Class II
Nominal operating voltage (Un) 120 V AC
Maximum continuous operating voltage (Uc) 150 V AC
Maximum discharge current (Imax) 40 kA
Nominal Discharge Current (In) 20 kA
Configuration TN-S
Number of poles 2 Poles
Module width 2 Modules
Assembly format Pluggable
Mounting type DIN rail
Remote indication No
Protection rating IP20
Short circuit withstand (ISCCR) 25 kA
Voltage protection level (Up) ≤ 0.9 kV
Standards EN/IEC 61643-11, UL 1449
HS Code 85363090
Country of Manufacture Spain

Frequently Asked Questions

What is the Mersen 83020120 used for?

It protects low voltage single phase TNS electrical systems from transient overvoltages caused by switching operations and indirect lightning strikes.

What type of surge protection device is it?

The Mersen 83020120 is a Type 2 / Class II surge protection device with a pluggable module design.

What voltage is this SPD designed for?

It is designed for 120 V AC single phase systems with a 150 V AC maximum continuous operating voltage.

What does the 2+0 TNS configuration mean?

The 2+0 TNS configuration provides surge protection across the line and neutral conductors in single phase TNS electrical systems.

Can the protection cartridge be replaced?

Yes. The pluggable cartridge design enables rapid replacement without replacing the complete surge protection assembly.

Trusted by Electrical Professionals Worldwide

Mersen Surge-Trap® surge protection devices are trusted by electrical engineers, panel builders and maintenance professionals to protect critical electrical infrastructure against damaging transient overvoltages.