Mersen Surge Protector Type 1+2 SPD 2 Pole 120 Volt 20KA TNS

Mersen Surge Protector Type 1+2 SPD 2 Pole 120 Volt 20KA TNS

Mersen 83120118 STPT12-12K440V-2PG Type 1+2 surge protection device with 12.5 kA lightning impulse current, 400 V nominal operating voltage, 1Ph+N 1+1 TT configuration, 2-pole pluggable DIN rail design and 2-module format.

SKU: 83120118Alt SKU: STPT12-12K150V-2PMPN: 83120118
Price
List Price £178.42 ex VAT
Your Price (ex VAT) Save 25%
£133.82 25% OFF
You save £44.61 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £133.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£133.82

Why Choose the Mersen 83120118 Surge Protection Device?

The Mersen 83120118 STPT12-12K440V-2PG is a robust Type 1+2 surge protection device (SPD) designed to protect low-voltage electrical installations against lightning currents and transient overvoltages. Part of the Mersen Surge-Trap® Pluggable STPT12 Series, it is suitable for incoming supply panels, main distribution boards and systems requiring dependable first-level surge protection.

This device provides combined protection for single-phase plus neutral systems, using a 1+1 TT configuration with L-N and N-PE protection modes. Its compact pluggable construction allows straightforward installation and fast module replacement during maintenance.

With a 12.5 kA lightning impulse current (10/350 μs), 400 V nominal operating voltage (Un) and 440 V L-N maximum continuous operating voltage (Uc), the 83120118 provides reliable protection for industrial, commercial and infrastructure electrical installations.

Key Advantages

  • Type 1+2 surge protection device for lightning current and transient overvoltage protection.
  • 12.5 kA Iimp (10/350 μs) lightning impulse current rating.
  • 50 kA maximum discharge current (8/20 μs).
  • 1Ph+N 1+1 TT configuration for single-phase plus neutral systems.
  • Compact 2-pole pluggable design for DIN rail installation.
  • Suitable as the first level of protection in main distribution boards.

Key Features

  • Mersen Surge-Trap® STPT12 Series.
  • Catalogue number: 83120118.
  • Model: STPT12-12K440V-2PG.
  • IEC Type 1+2 / Class I+II surge protection.
  • 400 V AC nominal operating voltage (Un).
  • 440 V AC maximum continuous operating voltage L-N.
  • 255 V AC maximum continuous operating voltage N-PE.
  • 2-pole, 2-module pluggable format.
  • DIN rail mounting.
  • Designed for 1+1 TT single-phase plus neutral configurations.

Reliable Protection Against Transient Overvoltages

Surge protection devices help protect electrical equipment from damaging voltage spikes caused by lightning activity, switching operations and disturbances on the power network. Installing a Type 1+2 SPD at the incoming supply point helps reduce the risk of equipment damage, downtime and disruption to critical electrical systems.

The Mersen STPT12 Series is engineered for low-voltage distribution applications where reliable surge protection, compact installation and straightforward maintenance are required. The pluggable module format allows protection cartridges to be replaced quickly without rewiring the complete assembly.

Typical Applications

  • Main electrical distribution boards.
  • Incoming power supply panels.
  • Single-phase plus neutral electrical systems.
  • Commercial building installations.
  • Industrial control panels.
  • Infrastructure and critical power systems.

Technical Specifications

Tick the specs you need, then view products that match.

Impulse Current Iimp (kA) 12.5 kA
Voltage 120 V
Phase Single Phase
Poles 2-pole
Device Type Surge protection device
SPD Type Type 1+2
Nominal Discharge Current (In) 20 kA
Earthing System TT
Manufacturer Mersen
Series Surge-Trap® Pluggable STPT12
Model STPT12-12K440V-2PG
Part number 83120118
Product type Type 1+2 Surge Protection Device
IEC classification Class I+II
Lightning impulse current (Iimp 10/350 μs) 12.5 kA
Maximum discharge current (Imax 8/20 μs) 50 kA
Nominal discharge current (In 8/20 μs) 20 kA
Nominal operating voltage (Un) 400 V AC
Maximum continuous operating voltage L-N (Uc) 440 V AC
Maximum continuous operating voltage N-PE (Uc) 255 V AC
Protection modes L-N / N-PE
System configuration 1+1 TT
Number of poles 2
Module width 2 modules
Mounting type DIN rail
Format Pluggable
HS Code 85363090
Country of Manufacture Spain

Frequently Asked Questions

What is the Mersen 83120118 used for?

It is used to protect single-phase plus neutral low-voltage electrical installations from lightning currents and transient overvoltages.

What type of surge protection device is it?

The 83120118 is a Type 1+2 (Class I+II) surge protection device for combined lightning current and surge protection.

What voltage is the Mersen 83120118 rated for?

It has a 400 V AC nominal operating voltage and a 440 V AC maximum continuous operating voltage L-N.

What system configuration does it support?

The Mersen 83120118 is designed for 1+1 TT single-phase plus neutral surge protection configurations.

Where is this SPD typically installed?

It is typically installed on a DIN rail in main distribution boards or incoming supply panels as the first level of surge protection.

Trusted Protection for Critical Electrical Systems

Mersen Surge-Trap® surge protection devices are trusted worldwide to help protect electrical installations, industrial equipment and critical infrastructure from the damaging effects of lightning strikes and transient overvoltages.