K2-4PG275-M Mersen Surge Protector Type 2 SPD 4 Pole 230/400 Volt 20KA TT Remote Indication

K2-4PG275-M Mersen Surge Protector Type 2 SPD 4 Pole 230/400 Volt 20KA TT Remote Indication

Mersen 44020401 K2-4PG275-M four-pole Type 2 surge protection device for 230/400 V AC TT and TNS systems, featuring a 20 kA nominal discharge current, 50 kA maximum discharge current and remote status indication.

SKU: 44020401Alt SKU: K2-4PG275-MMPN: 44020401
Price
List Price £163.95 ex VAT
Your Price (ex VAT) Save 25%
£122.96 25% OFF
You save £40.99 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £122.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£122.96

Why Choose the Mersen 44020401 K2-4PG275-M Surge Protection Device?

The Mersen 44020401, also known as the K2-4PG275-M, is a high-performance Type 2 surge protection device (SPD) designed to protect low-voltage electrical installations against transient overvoltages and induced lightning surges. As part of the advanced Mersen Surge-Trap® K2 Series, this four-pole surge arrester delivers reliable protection for sensitive equipment connected to three-phase power distribution systems.

Featuring a 3+1 protection configuration, the Mersen K2-4PG275-M provides L-N and N-PE surge protection for TT and TNS electrical networks. It has a nominal discharge current of 20 kA and a maximum discharge current of 50 kA, enabling it to safely divert powerful transient currents away from connected machinery, control systems and electronic equipment.

The device is designed for 230/400 V AC installations and has a maximum continuous operating voltage of 275 V AC between line and neutral. Its pluggable protection modules simplify maintenance, while integrated visual and remote indication functions allow the operating status of the SPD to be monitored locally or through a building management and control system.

Key Advantages

  • Dependable Type 2 surge protection for three-phase electrical systems.
  • 50 kA maximum discharge current for robust transient overvoltage protection.
  • 20 kA nominal discharge current using an 8/20 µs waveform.
  • Four-pole 3+1 configuration for L-N and N-PE protection.
  • Integrated remote indication microswitch for external status monitoring.
  • Pluggable protection modules support quick inspection and replacement.
  • Visual status indication provides clear end-of-life monitoring.
  • Compact DIN rail format simplifies control-panel installation.

Key Features

  • Mersen Surge-Trap® K2 Series.
  • Type 2 / IEC Class II surge protection device.
  • Four-pole 3+1 protection configuration.
  • 230/400 V AC nominal operating voltage.
  • 275 V AC maximum continuous operating voltage between line and neutral.
  • 50 kA maximum discharge current.
  • 20 kA nominal discharge current.
  • L-N and N-PE protection modes for TT and TNS systems.
  • Remote alarm contact for electrical status indication.
  • Green visual status indicator for operational monitoring.
  • Pluggable cartridges for simplified servicing.
  • DIN rail mounting for electrical distribution boards.

Surge Protection with Remote Status Monitoring

Transient overvoltages caused by indirect lightning strikes, utility network disturbances and the switching of inductive loads can damage sensitive electronic equipment. The Mersen 44020401 limits these voltage spikes by diverting surge energy away from connected machinery, control equipment and electrical distribution components.

Unlike the standard K2-4PG275 model, the K2-4PG275-M includes an integrated microswitch for remote indication. This contact can be connected to a building management system, alarm circuit or industrial controller, allowing maintenance teams to monitor the condition of the surge protection device without inspecting the distribution board manually.

Typical Applications

  • Commercial and industrial distribution boards.
  • Three-phase electrical control panels.
  • Building management and remote monitoring systems.
  • Manufacturing and process automation equipment.
  • Machinery control and production systems.
  • Data centres and telecommunications installations.
  • Renewable energy and infrastructure systems.
  • Electrical installations requiring Type 2 surge protection.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 400 V
Phase Three Phase
Poles 4-pole
Device Type Surge protection device
SPD Type Type 2
Earthing System TN-S, TT
Nominal Discharge Current (In) 20 kA
Remote Signal Yes
Manufacturer Mersen
Series Surge-Trap® K2 Series
Model K2-4PG275-M
Manufacturer part number 44020401
EAN 8435297884149
Product type Surge protection device
IEC SPD classification Type 2 / Class II
UL SPD classification Type 1 Component Assembly
Protection configuration 3+1
Nominal operating voltage 230/400 V AC
Maximum continuous operating voltage, L-N 275 V AC
Maximum continuous operating voltage, N-PE 255 V AC
Nominal frequency 50 / 60 Hz
Nominal Discharge Current (In) 20 kA
Maximum discharge current, Imax 50 kA
Voltage protection level, L-N ≤1.5 kV
Voltage protection level, N-PE ≤1.5 kV
Voltage protection level, L-PE ≤1.8 kV
Voltage protection rating, L-L 1,800 V
Voltage protection rating, L-N 1,000 V
Voltage protection rating, L-G 1,500 V
Voltage protection rating, N-G 900 V
Protection modes L-N / N-PE
System configuration TN-S, TT
Number of poles 4
Following current 100 A
Maximum back-up fuse 315 A gG
Remote indication Integrated microswitch
Remote contact rating 250 V AC at 0.5 A / 30 V DC at 1 A
Status indication Green operational / not green replace
Protection rating IP20
Mounting type DIN rail
Connection torque 3 N·m
Solid conductor capacity 1.5–35 mm²
Stranded conductor capacity 1.5–25 mm²
Operating temperature -40 to +85 °C
Maximum operating altitude 4,000 m
Housing material PA6 CT1 and PA66 CT1
Flammability rating UL94 V-0
Dimensions (H × W × D) 90 × 72 × 74.4 mm
Weight approx. 0.432 kg
RoHS compliant Yes
HS Code 85363090
Country of Manufacture Spain

Frequently Asked Questions

What is the Mersen 44020401 used for?

The Mersen 44020401 is a Type 2 surge protection device used to protect three-phase low-voltage electrical systems and connected equipment against transient overvoltages and induced lightning surges.

What is the maximum discharge current of the K2-4PG275-M?

The device has a maximum discharge current of 50 kA and a nominal discharge current of 20 kA using an 8/20 µs waveform.

What does the remote indication function do?

The integrated microswitch provides a remote electrical signal indicating the condition of the surge protector. It can be connected to an alarm, controller or building management system for remote monitoring.

Which electrical systems are compatible with this SPD?

The Mersen K2-4PG275-M is designed for 230/400 V AC TT and TNS systems and uses a four-pole 3+1 configuration with L-N and N-PE protection modes.

Can the protection cartridges be replaced?

Yes. The device uses pluggable surge protection cartridges, allowing individual modules to be inspected and replaced without changing the complete DIN rail base assembly.

Trusted Surge Protection from Mersen

Mersen Surge-Trap® protection devices are engineered to support electrical safety, equipment reliability and service continuity across demanding commercial, industrial and infrastructure installations.