K2-3P440-M Mersen Surge Protector Type 2 SPD 3 Pole 400/690 Volt 20KA IT Remote Indication

K2-3P440-M Mersen Surge Protector Type 2 SPD 3 Pole 400/690 Volt 20KA IT Remote Indication

Mersen 44020309 K2-3P440-M Type 2 three-pole surge protection device with integrated remote signalling for 400/690 V TN-C systems, featuring a 440 V AC maximum continuous operating voltage, 20 kA nominal discharge current and 50 kA maximum discharge current.

SKU: 44020309Alt SKU: K2-3P440-MMPN: 44020309
Price
List Price £131.24 ex VAT
Your Price (ex VAT) Save 25%
£98.43 25% OFF
You save £32.81 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £98.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£98.43

Why Choose the Mersen 44020309 K2-3P440-M Surge Protection Device?

The Mersen 44020309, also identified as the K2-3P440-M, is a premium Type 2 surge protection device (SPD) engineered to protect three-phase low-voltage electrical installations against transient overvoltages. Part of the trusted Mersen Surge-Trap K2 series, it is designed for 400/690 V TN-C electrical systems and is also suitable for 400 V IT network configurations. An integrated remote signalling contact enables continuous monitoring of the protection status from a central control system.

Its pluggable construction allows the protection cartridges to be replaced quickly without removing the complete DIN-rail base, reducing maintenance time and minimising downtime. A visual status indicator provides immediate local confirmation of the device condition, while the built-in microswitch transmits the operational status to PLCs, SCADA systems or building management systems.

With a 440 V AC maximum continuous operating voltage, 20 kA nominal discharge current and 50 kA maximum discharge current, the Mersen K2-3P440-M provides dependable protection against lightning-induced surges and switching transients in demanding commercial and industrial installations.

Key Advantages

  • Reliable Type 2 surge protection for three-phase 400/690 V electrical systems.
  • Integrated remote signalling microswitch for continuous condition monitoring.
  • 50 kA maximum discharge current for excellent transient overvoltage protection.
  • Suitable for TN-C systems and compatible with 400 V IT networks.
  • Replaceable plug-in cartridges simplify maintenance.
  • Visual operating status indication enables rapid inspection.

Key Features

  • Mersen Surge-Trap K2 series.
  • Type 2 / Class II surge protection device.
  • Three-pole (3+0) configuration.
  • 400/690 V AC nominal operating voltage.
  • 440 V AC maximum continuous operating voltage (Uc).
  • 20 kA nominal discharge current (In).
  • 50 kA maximum discharge current (Imax).
  • Protection mode: L-PE(N).
  • Integrated visual indication and remote signalling microswitch.
  • Dynamic thermal disconnection technology.
  • Replaceable plug-in cartridges.
  • Compact DIN-rail mounting.

Three-Phase Surge Protection with Remote Monitoring

Transient overvoltages generated by indirect lightning strikes, utility switching operations, motors, transformers and other inductive loads can damage PLCs, drives, communication equipment, power supplies and sensitive control electronics. A dedicated Type 2 SPD helps prevent costly equipment failures, minimise downtime and improve long-term electrical reliability.

The Mersen K2-3P440-M combines high surge current capability with integrated remote signalling, allowing maintenance personnel to monitor protection status remotely while benefiting from fast replacement of the plug-in protection cartridges whenever servicing is required.

Typical Applications

  • 400/690 V TN-C distribution boards.
  • 400 V IT electrical installations.
  • Industrial switchgear assemblies.
  • Motor control centres.
  • PLC and automation systems.
  • Commercial and industrial power distribution.
  • SCADA and building management systems.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 690 V
Phase Three Phase
Poles 3-pole
Device Type Surge protection device
SPD Type Type 2
Earthing System IT, TN-C
Nominal Discharge Current (In) 20 kA
Remote Signal Yes
Manufacturer Mersen
Series Surge-Trap K2
Model K2-3P440-M
SKU / Part number 44020309
Product type Surge protection device
IEC SPD classification Type 2 / Class II
UL SPD classification Type 1 Component Assembly
Configuration TN-C (also suitable for 400 V IT)
Number of poles 3
System configuration TN-C (also suitable for 400 V IT)
Protection mode L-PE(N)
Nominal operating voltage 400/690 V AC
Maximum continuous operating voltage 440 V AC
Nominal discharge current 20 kA
Maximum discharge current 50 kA
Voltage protection level ≤2.0 kV
Response time ≤25 ns
Residual current <1 mA
Short-circuit withstand rating 25 kA
Maximum back-up fuse 315 A gG
Dynamic thermal disconnection Yes
Thermal protection behaviour Open Circuit Mode (OCM)
Status indication Green (OK) / Not green (replace)
Remote signalling Integrated microswitch
Terminal tightening torque 3 Nm
Housing material PA6 CT1 & PA66 CT1
Mounting type DIN rail
DIN rail modules 3
Replacement cartridge Cartridge ID C34
Weight approx. 0.405 kg
EAN 8435297889922
RoHS compliant Yes
HS Code 85363090
Country of Manufacture Spain

Frequently Asked Questions

What is the Mersen 44020309 used for?

The Mersen 44020309 protects three-phase 400/690 V electrical installations against transient overvoltages while providing remote indication of the surge protection device status.

What type of surge protection device is the K2-3P440-M?

It is a Type 2 / Class II surge protection device designed as a secondary level of protection for low-voltage electrical installations.

Does the K2-3P440-M include remote signalling?

Yes. An integrated microswitch provides remote status indication to PLCs, SCADA systems, alarm circuits and building management systems.

Which electrical systems are compatible with this SPD?

The K2-3P440-M is designed for 400/690 V TN-C systems and is also suitable for 400 V IT network configurations.

What discharge current can the device withstand?

The device is rated for a 20 kA nominal discharge current and a 50 kA maximum discharge current using the standard 8/20 µs surge waveform.

Can the protection cartridges be replaced?

Yes. The pluggable construction allows the protection cartridges to be replaced without removing the complete DIN-rail base, reducing servicing time.

Trusted Surge Protection from Mersen

Mersen Surge-Trap K2 surge protection devices are trusted by electrical engineers, panel builders and maintenance professionals to protect critical three-phase electrical systems while providing dependable remote monitoring and simplified maintenance.