K2-2P440 Mersen Surge Protector Type 2 SPD 2 Pole 230/400 Volt 20KA IT

K2-2P440 Mersen Surge Protector Type 2 SPD 2 Pole 230/400 Volt 20KA IT

Mersen 44020218 K2-2P440 Type 2 two-pole surge protection device for 400 V AC TN-S systems, featuring a 440 V AC maximum continuous operating voltage, 20 kA nominal discharge current and 50 kA maximum discharge current.

SKU: 44020218Alt SKU: K2-2P440MPN: 44020218
Price
List Price £74.78 ex VAT
Your Price (ex VAT) Save 25%
£56.09 25% OFF
You save £18.70 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £56.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£56.09

Why Choose the Mersen 44020218 K2-2P440 Surge Protection Device?

The Mersen 44020218, also identified as the K2-2P440, is a robust Type 2 surge protection device (SPD) designed to protect low-voltage electrical installations against transient overvoltages. Part of the proven Mersen Surge-Trap K2 series, it is suitable as a second level of protection in distribution boards and other installations where damaging surges may be generated by lightning activity, utility switching or inductive electrical loads.

The K2-2P440 features a compact, pluggable two-pole construction that enables the protection cartridges to be inspected and replaced without removing the complete DIN-rail base. Its visual status indication displays green when the protection modules are operational and changes when replacement is required, helping maintenance teams identify the device condition quickly.

With a 400 V AC nominal operating voltage, a 440 V AC maximum continuous operating voltage to earth, a 20 kA nominal discharge current and a 50 kA maximum discharge current, the Mersen 44020218 delivers dependable surge protection for commercial and industrial TN-S electrical systems. Its compact two-module format makes it suitable for installation in distribution boards, switchgear assemblies and automation panels.

Key Advantages

  • Reliable Type 2 surge protection for 400 V AC electrical systems.
  • 50 kA maximum discharge current for robust transient overvoltage protection.
  • Pluggable protection cartridges simplify maintenance and replacement.
  • Visual status indication enables quick inspection of the device condition.
  • Compact two-pole DIN-rail design saves valuable enclosure space.
  • Suitable for commercial and industrial TN-S electrical installations.

Key Features

  • Mersen Surge-Trap K2 series.
  • Type 2 / Class II surge protection device.
  • Two-pole configuration.
  • 400 V AC nominal operating voltage.
  • 440 V AC maximum continuous operating voltage to earth.
  • 20 kA nominal discharge current (In).
  • 50 kA maximum discharge current (Imax).
  • Protection modes: L-PE and N-PE.
  • Green operational and replacement-required visual indication.
  • Fast metal oxide varistor response.
  • Replaceable plug-in protection modules.
  • Compact DIN-rail mounting format.

Dependable Surge Protection for 400 V Electrical Systems

Transient overvoltages can enter an electrical installation through the power supply network or be generated internally when motors, contactors, transformers and other inductive loads are switched. These short-duration voltage spikes can damage PLCs, drives, power supplies, communication equipment and other sensitive electronic devices.

The Mersen K2-2P440 diverts excessive surge energy towards earth before it reaches connected equipment. Its high discharge capacity, replaceable protection cartridges and clear visual indication help improve system reliability while simplifying routine maintenance in commercial and industrial installations.

Typical Applications

  • 400 V AC distribution boards.
  • Industrial switchgear and control panels.
  • Commercial electrical installations.
  • Motor control centres and automation cabinets.
  • PLC, drive and power-supply protection.
  • TN-S low-voltage electrical systems.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 400 V
Phase Single Phase
Poles 2-pole
Device Type Surge protection device
SPD Type Type 2
Earthing System IT, TN-S
Nominal Discharge Current (In) 20 kA
Remote Signal No
Manufacturer Mersen
Series Surge-Trap K2
Model K2-2P440
SKU / Part number 44020218
Product type Surge protection device
IEC SPD classification Type 2 / Class II
UL SPD classification Type 1 Component Assembly
Format Pluggable
Number of poles 2
System configuration TN-S (also suitable for 230 V IT)
Protection modes L-PE / N-PE
Nominal operating voltage 400 V AC
Maximum continuous operating voltage (L-G) 440 V AC
Maximum continuous operating voltage (N-G) 440 V AC
Maximum continuous operating voltage (L-N) 880 V AC
Nominal discharge current 20 kA
Maximum discharge current 50 kA
Surge current waveform 8/20 µs
Voltage protection rating (L-G) 1,500 V
Voltage protection rating (N-G) 1,500 V
Voltage protection rating (L-N) 2,500 V
MOV response time ≤25 ns
Short-circuit withstand rating 25 kA
Maximum back-up fuse 315 A gG
Status indication Green (OK) / Not green (replace)
Terminal tightening torque 3 Nm
Housing material PA6 CT1 and PA66 CT1
Mounting type DIN rail
Replacement plug Mersen 44020005
Dimensions (H × W × D) 90 × 36 × 74.4 mm
Product weight approx. 0.223 kg
RoHS compliant Yes
EAN / UPC 8435297889847

Frequently Asked Questions

What is the Mersen 44020218 used for?

The Mersen 44020218 protects 400 V AC low-voltage electrical installations and connected equipment against transient overvoltages caused by lightning activity, utility switching and inductive loads.

What type of surge protection device is the K2-2P440?

It is a Type 2 / Class II surge protection device intended primarily as a second level of surge protection in commercial and industrial electrical installations.

What discharge current can the device withstand?

The K2-2P440 has a 20 kA nominal discharge current and a 50 kA maximum discharge current based on the standard 8/20 µs surge waveform.

Does the Mersen 44020218 include remote signalling?

No. This version provides local visual status indication. Applications requiring an integrated remote signalling contact should use the corresponding monitored K2 model where specified.

Can the protection cartridges be replaced?

Yes. The pluggable design allows the protection cartridges to be replaced without removing the complete DIN-rail base. The specified replacement plug is Mersen part number 44020005.

Trusted Surge Protection from Mersen

Mersen Surge-Trap K2 surge protection devices are trusted by electrical engineers, panel builders and maintenance professionals to protect critical low-voltage electrical installations against damaging transient overvoltages.