Finder 7P.68.9.060.0600 is a Type 3 Ethernet Cat 6 surge protection device for compatible data and Power over Ethernet connections. Featuring 48 V DC nominal voltage, 60 V DC maximum continuous operating voltage, 500 mA nominal load current, protection of all four Ethernet pairs, shielded RJ45 input and output connectors, data transmission support up to 250 MHz, 1.6 kA C2 total line-to-ground nominal discharge current, 200 A C2 line-to-line nominal discharge current and 35 mm DIN rail mounting.
£105.27
The Finder 7P.68.9.060.0600 is a specialist Type 3 Ethernet surge protection device (SPD) designed to protect Cat 6 network connections, Power over Ethernet (PoE) circuits and compatible data transmission equipment against transient overvoltages. Part of the Finder 7P Series, this network surge arrester provides protection for all eight Ethernet conductors while supporting data transmission frequencies up to 250 MHz.
Designed for 48 V DC nominal systems, the Finder 7P.68.9.060.0600 has a maximum continuous operating voltage (Uc) of 60 V DC and a nominal load current of 500 mA. It is suitable for compatible Ethernet and PoE installations where sensitive networking equipment may be exposed to transient voltage spikes caused by nearby lightning activity, electrical switching operations or disturbances entering through connected data cables.
The device incorporates shielded RJ45 input and output connectors, allowing it to be installed directly in the Ethernet cable path. Its protective arrangement covers all four conductor pairs, providing differential-mode and common-mode surge suppression while maintaining the transmission characteristics required for Cat 6 applications.
With a 1.6 kA C2 total nominal discharge current between the data lines and protective ground, a 200 A C2 nominal discharge current between conductors and a fast 1 ns response time, the Finder 7P.68.9.060.0600 offers defined surge protection performance for compatible network infrastructure.
The robust aluminium housing, shielded RJ45 connections and supplied mounting accessories make the device a practical solution for network cabinets, industrial control panels, security installations and other locations where Ethernet equipment requires additional protection against electrical transients.
Ethernet cabling is widely used to connect industrial automation equipment, security devices, network switches, wireless access points, IP cameras and other communications equipment. Although these connections normally operate at relatively low voltages, long cable runs and exposed wiring routes can provide a path for transient overvoltages to reach sensitive electronic interfaces.
The Finder 7P.68.9.060.0600 is designed to help protect compatible Ethernet networks against these disturbances. Installed in-line with the network cable, it provides surge suppression for all eight Ethernet conductors, helping limit transient voltage differences between individual lines and between the data lines and protective ground.
The device is specifically intended for Cat 6 Ethernet cabling and supports transmission frequencies up to 250 MHz. This allows it to be incorporated into compatible structured cabling systems while maintaining the frequency characteristics required for the intended network connection.
Its specified insertion attenuation of less than 2 dB at 250 MHz is an important consideration for data transmission performance. The actual operation of a complete network link also depends on cable length, connector quality, cable category and the electrical characteristics of the connected equipment.
The shielded RJ45 input and output connectors simplify installation and help maintain the shielding arrangement of compatible Ethernet cables. The aluminium chassis provides a durable enclosure, while the protective grounding arrangement allows common-mode surge currents to be diverted through the intended path.
Unlike a conventional mains surge arrester, this device is specifically engineered for Ethernet data line protection. It should not be used as a substitute for a 230 V AC power SPD or connected directly across mains power conductors.
Power over Ethernet allows electrical power and network data to be transmitted through the same Ethernet cable. This technology is commonly used for IP cameras, wireless access points, VoIP equipment and industrial networking devices.
The Finder 7P.68.9.060.0600 is designed for compatible PoE applications, providing surge protection while allowing the Ethernet connection to carry data and power within the specified electrical limits.
The device has a 48 V DC nominal voltage, a 60 V DC maximum continuous operating voltage and a 500 mA nominal load current. These ratings must be checked against the actual operating conditions of the connected PoE equipment.
Not every PoE installation has the same electrical requirements. Higher-power PoE systems may use currents that exceed the nominal load current specified for this SPD. Compatibility should therefore be confirmed for the particular PoE standard, power sourcing equipment and powered device before installation.
When correctly selected and installed, the Finder 7P.68.9.060.0600 can provide an additional protective measure for Ethernet equipment exposed to transient overvoltages travelling along network cabling.
The Finder 7P.68.9.060.0600 provides Type 3 surge protection intended for installation near sensitive network equipment, typically at the boundary between LPZ 2 and LPZ 3.
Under the C2 test classification, the device has a 1.6 kA total nominal discharge current for line-to-protective-ground surges and a 200 A nominal discharge current for line-to-line surges, measured using the standard 8/20 µs waveform.
The specified C2 voltage protection level is 130 V line-to-line and 350 V line-to-ground. These values help engineers assess the protection characteristics of the device under the relevant surge test conditions.
Under C3 testing, the device has a 130 V line-to-line voltage protection level at a voltage rise rate of 1 kV/µs.
The specified 1 ns response time supports rapid reaction to transient overvoltages. However, effective protection depends on the complete installation, including grounding, cable routing and coordination with other surge protection devices.
Where a network cable runs between buildings or through particularly exposed locations, additional protective measures may be required at other points along the cable route. The Finder 7P.68.9.060.0600 should be selected as part of an appropriately designed surge protection system rather than treated as a guarantee against all lightning-related damage.
The Finder 7P.68.9.060.0600 uses shielded RJ45 input and output connections, allowing it to be installed in-line between the incoming Ethernet cable and the equipment requiring protection.
For effective protection, the device should be positioned as close as practicable to the protected equipment, with the grounding arrangement completed according to Finder's installation instructions.
The SPD can be mounted onto a standard 35 mm DIN rail according to EN 60715. Finder also specifies supplied accessories to support installation near the protected equipment.
The device's aluminium chassis and shielded RJ45 connectors are intended for professional data and communications installations. The cable shielding and protective ground connection should be arranged correctly to maintain the intended surge protection path.
Its IP20 protection rating means the device should be installed within a suitable enclosure or protected indoor location. It is not intended for unprotected exposure to rain, water ingress or other harsh outdoor conditions.
Before installation, confirm that the Ethernet link operates within the device's 60 V DC maximum voltage, 500 mA nominal load current and supported transmission characteristics.
Installation and inspection should be carried out by a competent professional following Finder's instructions and the applicable requirements for electrical safety, structured cabling and surge protection.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Product family | 7P.68 |
| Manufacturer part number | 7P.68.9.060.0600 |
| Alternative code | 7P6890600600 |
| EAN / GTIN | 8012823398082 |
| Product type | Ethernet data line surge protection device |
| SPD classification | Type 3 |
| Network application | Ethernet Cat 6 |
| Power over Ethernet | Supported within specified ratings |
| Number of protected conductors | 8 |
| Number of protected pairs | 4 |
| Nominal system voltage (Un) | 48 V DC |
| Maximum continuous operating voltage (Uc) | 60 V DC |
| Nominal load current (IL) | 500 mA / 0.5 A |
| C2 total nominal discharge current, line-to-protective-ground (In) | 1.6 kA |
| C2 nominal discharge current, line-to-line (In) | 200 A |
| Discharge current waveform | 8/20 µs |
| C2 voltage protection level, line-to-line at In | 130 V |
| C2 voltage protection level, line-to-ground at In | 350 V |
| C3 voltage protection level, line-to-line at 1 kV/µs | 130 V |
| Insertion attenuation at 250 MHz | < 2 dB |
| Response time | 1 ns |
| Supported transmission frequency | Up to 250 MHz |
| Input connection | Shielded RJ45 |
| Output connection | Shielded RJ45 |
| Housing material | Aluminium |
| Mounting | 35 mm DIN rail, EN 60715 |
| Overall height | Approximately 54 mm |
| Overall width | Approximately 25 mm |
| Overall depth | Approximately 90 mm |
| Ingress protection | IP20 |
| Operating temperature range | -40 °C to +80 °C |
| Applicable product standard | EN 61643-21 |
| Approximate net weight | 112.8 g |
| Recommended installation position | Near the equipment requiring protection |
| Typical lightning protection zone boundary | LPZ 2 to LPZ 3 |
The Finder 7P.68.9.060.0600 is a Type 3 surge protection device designed for compatible Ethernet Cat 6 data lines and Power over Ethernet connections. It helps protect sensitive networking equipment against transient overvoltages.
Yes. Finder specifically identifies this model for Ethernet Cat 6 applications, with supported data transmission frequencies up to 250 MHz and protection for all four conductor pairs.
Yes. The device is designed for compatible PoE applications. However, its 60 V DC maximum operating voltage and 500 mA nominal load current must be checked against the requirements of the connected PoE equipment.
The Finder 7P.68.9.060.0600 is a Type 3 SPD, intended for fine surge protection near sensitive Ethernet equipment, typically at the boundary between lightning protection zones LPZ 2 and LPZ 3.
The device has a maximum continuous operating voltage (Uc) of 60 V DC and a nominal system voltage of 48 V DC.
Under C2 testing, the device has a 1.6 kA total nominal discharge current for line-to-protective-ground surges and a 200 A nominal discharge current for line-to-line surges, measured using the 8/20 µs waveform.
Yes. The device is designed to provide surge protection for all four Ethernet conductor pairs, covering all eight conductors within a standard four-pair Ethernet connection.
The device uses shielded RJ45 input and output connectors, allowing it to be installed in-line with compatible Ethernet cabling.
The device is designed for Cat 6 data transmission up to 250 MHz, with a specified insertion attenuation of less than 2 dB at 250 MHz. Overall network performance also depends on the complete cabling installation.
The device is connected in-line using its shielded RJ45 ports and can be mounted on a standard 35 mm DIN rail. It should be installed close to the equipment requiring protection, with the grounding arrangement completed according to Finder's instructions.
The device has an IP20 protection rating and is not suitable for unprotected outdoor exposure. Outdoor applications require a suitable enclosure providing the necessary environmental protection.
The device is specified for an operating temperature range of -40 °C to +80 °C, subject to correct installation conditions.
The Finder 7P.68.9.060.0600 provides specialist Type 3 surge protection for compatible Ethernet Cat 6 and Power over Ethernet installations. Combining all-pair protection, shielded RJ45 connectivity, 250 MHz transmission support, a 60 V DC maximum operating voltage and fast surge response, it is a practical choice for protecting sensitive network interfaces against transient overvoltages.
Manufacturer documentation: Finder 7P Series Surge Protection Devices Technical Catalogue.