Finder 7P.27.8.275.1020 is a Type 2 surge protection device for single-phase TN-S electrical systems, featuring two replaceable varistor protection modules, 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current and integrated remote status signalling.
£95.48
The Finder 7P.27.8.275.1020 is a Type 2 surge protection device (SPD) designed for single-phase TN-S electrical installations. Part of the Finder 7P Series, this surge arrester protects electrical equipment against transient overvoltages caused by induced lightning surges and electrical switching operations.
Designed for 230 V AC single-phase systems, the Finder 7P.27.8.275.1020 features a 275 V AC maximum continuous operating voltage (Uc), a 20 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax), measured using the 8/20 µs surge waveform. Its two metal oxide varistor protection paths provide surge protection between the line and protective earth and between the neutral and protective earth conductors.
Unlike the corresponding version without remote monitoring, the 7P.27.8.275.1020 includes an integrated remote status signalling contact. Combined with replaceable varistor cartridges and optical condition indicators, this feature allows maintenance personnel to monitor the device's protective status locally or through compatible external alarm and monitoring equipment.
Electrical installations can experience short-duration transient overvoltages resulting from lightning activity, electrical switching operations and disturbances within the power distribution network. These events can damage electronic equipment, interrupt industrial processes and reduce the operational reliability of connected systems.
The Finder 7P.27.8.275.1020 uses two metal oxide varistor protection elements to limit transient overvoltages in compatible single-phase TN-S systems. The device provides protection between the line and protective earth and between the neutral and protective earth conductors. Its 20 kA nominal discharge current and 40 kA maximum discharge current make it suitable for appropriately selected Type 2 surge protection applications.
A key feature of the 7P.27.8.275.1020 is its integrated remote signalling contact. The changeover contact can be connected to a compatible alarm circuit, building management system or industrial monitoring input, allowing the condition of the SPD to be monitored without relying solely on manual inspection.
The device also includes replaceable varistor cartridges and local optical condition indicators. When a protective module reaches the end of its service life, maintenance personnel can identify the affected cartridge and replace it with the corresponding Finder replacement module, subject to the manufacturer's safe isolation and servicing instructions.
Its compact 35 mm DIN rail-mounted housing occupies two modular spaces and is designed for installation within suitable electrical distribution enclosures. The SPD is particularly useful in applications where both surge protection and remote condition monitoring are required.
Important installation consideration: This device is designed for compatible single-phase TN-S electrical systems. It must be selected according to the system voltage, earthing arrangement, prospective short-circuit current and required surge protection coordination. The remote signalling contact is intended for status monitoring and must not be used as a power switching contact beyond its specified ratings. Installation and servicing should be performed by a suitably qualified electrician.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Model | 7P.27.8.275.1020 |
| Manufacturer part number | 7P.27.8.275.1020 |
| Product type | Surge protection device |
| SPD classification | Type 2 |
| Electrical system | Single-phase AC |
| Compatible earthing system | TN-S |
| Protection arrangement | L-PE and N-PE |
| Number of protected conductors | 2 |
| Protection technology | Metal oxide varistor |
| Number of varistor protection elements | 2 |
| Nominal system voltage | 230 V AC |
| Maximum continuous operating voltage (Uc) | 275 V AC |
| Nominal discharge current (In), 8/20 µs | 20 kA |
| Maximum discharge current (Imax), 8/20 µs | 40 kA |
| Voltage protection level (Up) | 1.35 kV |
| Voltage protection level at 5 kA | 0.9 kV |
| Short-circuit current rating (ISCCR) | 50 kA |
| Maximum upstream fuse rating | 160 A gG |
| Protection modules | Replaceable varistor cartridges |
| Replacement varistor module | 7P.20.8.275.0020 |
| Local status indication | Optical condition indicator |
| Remote signalling | Yes |
| Remote contact configuration | 1 changeover (SPDT) |
| Remote contact rated current | 0.5 A AC / 0.1 A DC |
| Remote contact rated voltage | 250 V AC / 30 V DC |
| Mounting method | 35 mm DIN rail |
| Modular width | 2 DIN modules |
| Overall width | 35.8 mm |
| Overall depth | 65.9 mm |
| Ingress protection | IP20 |
| Operating ambient temperature | −40 to +80 °C |
| Typical installation location | LPZ 1 to LPZ 2 boundary |
| Country of origin | Czech Republic |
| EAN | 8012823394015 |
The Finder 7P.27.8.275.1020 is a Type 2 surge protection device designed to protect compatible single-phase TN-S electrical systems against induced lightning surges and electrical switching transients.
It is a Type 2 surge protection device, intended to limit transient overvoltages caused by switching operations and induced lightning activity.
The Finder 7P.27.8.275.1020 is designed for single-phase TN-S systems with separate line, neutral and protective earth conductors.
The device uses two metal oxide varistor protection elements connected between L-PE and N-PE. These elements respond to transient overvoltages by diverting surge current through the protective circuit.
The Finder 7P.27.8.275.1020 has a 275 V AC maximum continuous operating voltage (Uc) and is designed for compatible 230 V AC single-phase systems.
The device provides a 20 kA nominal discharge current (In), measured using the 8/20 µs surge waveform.
The surge arrester has a 40 kA maximum discharge current (Imax), measured using the 8/20 µs surge waveform.
The Finder 7P.27.8.275.1020 has a specified 1.35 kV voltage protection level (Up), helping limit transient overvoltages reaching connected electrical equipment.
Yes. The device includes an integrated remote status signalling contact that allows its operational condition to be monitored through compatible external alarm or monitoring equipment.
The SPD provides one changeover (SPDT) contact, rated at 0.5 A at 250 V AC or 0.1 A at 30 V DC.
Yes. The device incorporates replaceable varistor cartridges. The corresponding replacement module is Finder 7P.20.8.275.0020.
Both models are Type 2 surge protection devices for compatible single-phase TN-S systems. The 7P.27.8.275.1020 includes a remote signalling contact, while the 7P.27.8.275.0020 provides local optical indication without remote signalling.
The device mounts on a 35 mm DIN rail and occupies two modular spaces, with an overall width of approximately 35.8 mm.
The device has a specified maximum upstream fuse rating of 160 A gG. The actual backup protection must be selected according to Finder's installation instructions and the electrical system design.
The SPD has an IP20 ingress protection rating and must be installed inside an appropriately rated electrical enclosure. It is not intended for unprotected outdoor mounting.
The Finder 7P.27.8.275.1020 is specified for operation between −40 and +80 °C.
Finder 7P Series surge protection devices provide practical solutions for protecting low-voltage electrical installations against transient overvoltages. Combining Type 2 protection, single-phase TN-S compatibility, 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current, replaceable varistor modules and integrated remote status signalling, the Finder 7P.27.8.275.1020 supports electrical contractors, industrial panel builders, facilities engineers and electrical maintenance professionals.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.