Finder 7P.27.8.275.0020 - 7P Series Surge Protection Devices

Finder 7P.27.8.275.0020 – 7P Series Surge Protection Devices

Finder 7P.27.8.275.0020 is a Type 2 surge protection device for single-phase TN-S electrical systems, featuring two varistor protection elements, 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current and replaceable modules with local visual status indication.

SKU: 7P.27.8.275.0020Alt SKU: 7P2782750020MPN: 7P.27.8.275.0020
Price
List Price £93.57 ex VAT
Your Price (ex VAT) Save 25%
£70.18 25% OFF
You save £23.39 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £70.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£70.18

Why Choose the Finder 7P.27.8.275.0020 Type 2 Surge Protection Device?

The Finder 7P.27.8.275.0020 is a Type 2 surge protection device (SPD) designed to protect single-phase TN-S electrical installations against transient overvoltages caused by lightning-induced surges and electrical switching operations. Part of the Finder 7P Series, this surge arrester features a two-varistor protection arrangement for systems with separate neutral and protective earth conductors.

Designed for 230 V AC single-phase electrical systems, the Finder 7P.27.8.275.0020 has a 275 V AC maximum continuous operating voltage (Uc), a 20 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax), measured using the 8/20 µs surge waveform. Its 1.5 kV voltage protection rating helps reduce the effects of transient overvoltages on connected electrical equipment.

The device incorporates replaceable varistor protection modules and local visual status indication, enabling maintenance personnel to identify when protective elements require replacement. Designed for 35 mm DIN rail mounting, it provides a practical solution for single-phase distribution boards, industrial control panels and commercial electrical installations.

Key Advantages

  • Type 2 surge protection: Helps protect electrical installations against induced lightning surges and switching transients.
  • Single-phase TN-S compatibility: Designed for electrical systems with separate neutral and protective earth conductors.
  • Two-varistor protection: Provides surge protection through the device's specified L/N-to-PE arrangement.
  • 20 kA nominal discharge current: Supports reliable handling of transient surge currents.
  • 40 kA maximum discharge current: Provides additional capability against higher-energy transient events.
  • 275 V AC continuous operating voltage: Suitable for compatible 230 V AC single-phase installations.
  • 1.5 kV voltage protection rating: Helps limit surge voltages reaching downstream equipment.
  • Replaceable varistor modules: Simplifies servicing without replacing the complete SPD assembly.
  • Visual status indication: Allows local inspection of the condition of the protective elements.
  • DIN rail mounting: Supports straightforward integration into compatible electrical distribution enclosures.
  • IP20 ingress protection: Suitable for mounting within appropriately rated electrical enclosures.
  • Wide operating temperature range: Designed for operation between −40 and +80 °C.
  • Coordinated protection capability: Suitable for properly designed surge protection systems at LPZ 1 to LPZ 2 boundaries.

Key Features

  • Finder 7P Series surge protection device.
  • Type 2 SPD classification.
  • Single-phase TN-S network application.
  • 1+NPE protection arrangement.
  • Two metal oxide varistor protection elements.
  • 230 V AC nominal system voltage.
  • 275 V AC maximum continuous operating voltage (Uc).
  • 20 kA nominal discharge current (In), 8/20 µs.
  • 40 kA maximum discharge current (Imax), 8/20 µs.
  • 1.5 kV voltage protection rating.
  • Replaceable varistor modules.
  • Local visual protection status indication.
  • No remote signalling contact on the .0020 version.
  • 35 mm DIN rail mounting according to EN 60715.
  • IP20 ingress protection.
  • −40 to +80 °C operating temperature range.
  • EN 61643-11:2012 compliance.
  • EAN 8012823398167.

Reliable Type 2 Surge Protection for Single-Phase TN-S Electrical Installations

Electrical distribution systems are exposed to transient overvoltages resulting from lightning activity, electrical switching operations and disturbances within the supply network. These short-duration voltage peaks can damage sensitive electronic equipment, interrupt industrial processes and reduce the reliability of electrical installations. The Finder 7P.27.8.275.0020 Type 2 surge arrester is designed to help protect compatible single-phase TN-S systems against these disturbances.

The device uses two metal oxide varistor protection elements to respond rapidly to transient overvoltages and divert surge current through the protective circuit. Its 20 kA nominal discharge current and 40 kA maximum discharge current provide surge handling capability for appropriately selected Type 2 protection applications.

With a 275 V AC maximum continuous operating voltage, the Finder 7P.27.8.275.0020 is intended for compatible 230 V AC single-phase TN-S installations. The protection arrangement is designed for systems with neutral and protective earth conductors, helping limit the voltage stress imposed on connected equipment during transient surge events.

The replaceable varistor cartridges allow protective elements to be renewed when required, while the local visual indicators assist maintenance personnel in checking the device's condition. Its DIN rail mounting arrangement makes it suitable for electrical distribution boards and industrial control enclosures.

Installation consideration: The Finder 7P.27.8.275.0020 is a Type 2 SPD and must be selected according to the electrical system voltage, earthing arrangement, prospective fault current and required surge protection coordination. Any necessary upstream protective device must be selected in accordance with Finder's installation instructions. Installation and servicing should be carried out by a suitably qualified electrician.

Typical Applications

  • Single-phase TN-S electrical distribution networks.
  • 230 V AC electrical distribution boards.
  • Commercial building electrical infrastructure.
  • Industrial electrical control panels.
  • Automation and machinery supply protection.
  • Building management and monitoring systems.
  • Electrical installations requiring Type 2 surge protection.
  • Electrical distribution systems with separate neutral and protective earth conductors.
  • Protection of sensitive electronic equipment against transient overvoltages.
  • Coordinated surge protection at LPZ 1 to LPZ 2 boundaries.
  • Electrical panel-building and OEM applications.
  • Maintenance and replacement of electrical surge protection equipment.

Technical Specifications

Manufacturer Finder
Series 7P Series
Model 7P.27.8.275.0020
Manufacturer part number 7P.27.8.275.0020
Product type Surge protection device
SPD classification Type 2
Electrical system Single-phase AC
Compatible earthing system TN-S
Protection configuration 1+NPE
Number of protection elements 2
Protection technology Metal oxide varistor
Nominal system voltage 230 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Nominal discharge current (In), 8/20 µs 20 kA
Maximum discharge current (Imax), 8/20 µs 40 kA
Voltage protection rating 1.5 kV
Protection modules Replaceable varistor cartridges
Local status indication Visual varistor condition indicator
Remote signalling contact No
Mounting method DIN rail
DIN rail size 35 mm
Mounting standard EN 60715
Ingress protection IP20
Operating ambient temperature −40 to +80 °C
Applicable standard EN 61643-11:2012
Typical installation position LPZ 1 to LPZ 2 transition
EAN 8012823398167

Frequently Asked Questions

What is the Finder 7P.27.8.275.0020 used for?

The Finder 7P.27.8.275.0020 is a Type 2 surge protection device designed to protect compatible single-phase TN-S electrical installations against transient overvoltages caused by induced lightning surges and electrical switching operations.

Is the Finder 7P.27.8.275.0020 a Type 1 or Type 2 surge protector?

It is a Type 2 surge protection device, intended for protection against induced lightning surges and switching overvoltages rather than serving as a standalone Type 1 lightning current arrester.

Which electrical network is compatible with this SPD?

The Finder 7P.27.8.275.0020 is designed for single-phase TN-S electrical systems with separate neutral and protective earth conductors.

What does the 1+NPE configuration mean?

The 1+NPE configuration identifies the device's protection arrangement for a single-phase system incorporating line, neutral and protective earth connections. This model uses two varistor protection elements.

What is the maximum continuous operating voltage?

The Finder 7P.27.8.275.0020 has a 275 V AC maximum continuous operating voltage (Uc) and is intended for compatible 230 V AC single-phase installations.

What is the nominal discharge current of the Finder 7P.27.8.275.0020?

The device provides a 20 kA nominal discharge current (In), measured using the 8/20 µs surge waveform.

What is the maximum discharge current of this surge arrester?

The Finder 7P.27.8.275.0020 has a 40 kA maximum discharge current (Imax), measured using the 8/20 µs surge waveform.

What voltage protection rating does this SPD provide?

The device has a specified 1.5 kV voltage protection rating, helping limit transient overvoltages reaching connected equipment.

Does the Finder 7P.27.8.275.0020 have replaceable modules?

Yes. The surge arrester features replaceable varistor cartridges, allowing the protective elements to be renewed when required without replacing the complete compatible SPD assembly.

Does the Finder 7P.27.8.275.0020 include remote signalling?

No. The 7P.27.8.275.0020 does not include a remote signalling contact. It provides local visual indication of the condition of its protective elements.

How is the Finder 7P.27.8.275.0020 mounted?

The device is designed for mounting on a 35 mm DIN rail according to EN 60715 inside a suitable electrical distribution enclosure.

Can the Finder 7P.27.8.275.0020 be used in a three-phase installation?

The Finder 7P.27.8.275.0020 is intended for single-phase TN-S applications. Three-phase installations generally require an appropriately selected multi-pole SPD matched to the system voltage and earthing arrangement.

What is the difference between the Finder 7P.27.8.275.0020 and 7P.22.8.275.0020?

Both models are Type 2 surge protection devices for compatible single-phase systems. The 7P.27.8.275.0020 uses two varistor protection elements, while the 7P.22.8.275.0020 uses a varistor and an encapsulated spark-gap protection arrangement. Selection depends on the required network configuration and manufacturer's installation guidance.

What is the operating temperature range of this SPD?

The Finder 7P.27.8.275.0020 is designed for operation between −40 and +80 °C.

Can the Finder 7P.27.8.275.0020 be installed outdoors?

The device has an IP20 ingress protection rating and is not intended for unprotected outdoor mounting. It should be installed inside an appropriately rated electrical enclosure.

Trusted by Electrical Contractors, Panel Builders and Maintenance Engineers

Finder 7P Series surge protection devices provide practical solutions for protecting low-voltage electrical distribution systems against induced lightning surges and switching overvoltages. Combining Type 2 protection, single-phase TN-S compatibility, two-varistor construction, 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current, replaceable modules and local visual status indication, the Finder 7P.27.8.275.0020 supports electrical contractors, industrial panel builders, facilities engineers and electrical maintenance professionals.