Finder 7P.23.8.150.1015 is a three-pole Type 2 surge protection device with three replaceable varistor modules, 150 V AC maximum continuous operating voltage, 15 kA nominal discharge current, 40 kA maximum discharge current and remote status signalling.
£120.73
The Finder 7P.23.8.150.1015 is a three-pole Type 2 surge protection device (SPD) designed to protect compatible three-phase electrical installations against transient overvoltages caused by electrical switching operations and induced lightning surges. Part of the Finder 7P Series, this surge arrester combines three varistor protection modules, visual status indication and remote signalling capability in a compact DIN rail-mounted assembly.
Featuring a 150 V AC maximum continuous operating voltage (Uc), the Finder 7P.23.8.150.1015 is designed for compatible lower-voltage three-phase systems. It provides a 15 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax), measured using the 8/20 µs surge waveform.
The device incorporates replaceable varistor modules, allowing individual protective elements to be replaced when required. Its visual status indicators and remote signalling contact help maintenance personnel monitor the condition of the surge protection system, making it suitable for electrical distribution boards, industrial control panels and commercial electrical infrastructure.
Transient overvoltages can occur in electrical distribution systems as a result of lightning activity, electrical switching operations and disturbances in connected equipment. These short-duration voltage peaks can damage electronic components, disrupt industrial processes and reduce the reliability of electrical installations. The Finder 7P.23.8.150.1015 is designed to limit such transient overvoltages in compatible three-phase electrical systems.
Its three metal oxide varistors respond to excessive voltage by conducting surge current away from the protected circuit. The specified 15 kA nominal discharge current and 40 kA maximum discharge current provide protection capability for appropriately selected Type 2 SPD applications.
The device is intended for installation in a suitable electrical distribution enclosure, typically at a surge protection zone transition such as LPZ 1 to LPZ 2. Its replaceable modules allow maintenance personnel to renew protective elements following end-of-life indication, while the remote signalling contact enables the SPD's condition to be monitored through compatible control and alarm systems.
Installation consideration: The 150 V AC maximum continuous operating voltage must be checked against the actual system voltage and earthing arrangement. This model should not be selected solely because the installation is three-phase; it must be compatible with the voltage present across each protected connection. Upstream protection, prospective fault current and SPD coordination must also be considered according to Finder's installation instructions.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Model | 7P.23.8.150.1015 |
| Manufacturer part number | 7P.23.8.150.1015 |
| Product type | Surge protection device |
| SPD classification | Type 2 |
| Electrical system | Three-phase AC |
| Number of poles | 3 |
| Protection technology | Metal oxide varistor |
| Protection configuration | Three varistors |
| Nominal system voltage | 120 V AC |
| Maximum continuous operating voltage (Uc) | 150 V AC |
| Nominal discharge current (In), 8/20 µs | 15 kA |
| Maximum discharge current (Imax), 8/20 µs | 40 kA |
| Voltage protection level (Up) | 0.74 kV |
| Voltage protection level at 5 kA (Up5) | 0.6 kV |
| Protection modules | Replaceable varistor cartridges |
| Local status indication | Visual varistor condition indicator |
| Remote signalling | Yes |
| Remote contact configuration | 1 changeover contact |
| Remote contact rated voltage | 250 V AC / 30 V DC |
| Remote contact rated current | 0.5 A AC / 0.1 A DC |
| Mounting | 35 mm DIN rail according to EN 60715 |
| Modular width | 3 DIN modules |
| Ingress protection | IP20 |
| Operating ambient temperature | −40 to +80 °C |
| Application | Low-voltage electrical distribution surge protection |
The Finder 7P.23.8.150.1015 is a three-pole Type 2 surge protection device designed to protect compatible three-phase electrical installations against transient overvoltages caused by switching operations and induced lightning surges.
It is a Type 2 surge protection device. It is intended for protection against induced lightning surges and switching overvoltages rather than serving as a standalone Type 1 direct lightning current arrester.
The device has three poles and incorporates three varistor protection modules for compatible three-phase electrical systems.
The Finder 7P.23.8.150.1015 has a 150 V AC maximum continuous operating voltage (Uc). This rating must be compatible with the voltage across the protected connections.
The device provides a 15 kA nominal discharge current (In), measured using the 8/20 µs surge waveform.
The surge arrester has a 40 kA maximum discharge current (Imax), measured using the 8/20 µs waveform.
The Finder 7P.23.8.150.1015 has a specified 0.74 kV voltage protection level (Up) and a 0.6 kV protection level at 5 kA.
Yes. The device incorporates replaceable varistor cartridges, allowing the protective elements to be replaced when necessary without changing the complete compatible SPD assembly.
Yes. The 7P.23.8.150.1015 includes remote status signalling capability, allowing the condition of the protective modules to be monitored through a compatible external control or alarm circuit.
The device provides a changeover contact for remote status signalling, rated at 0.5 A at 250 V AC or 0.1 A at 30 V DC.
The surge arrester is designed for installation on a 35 mm DIN rail according to EN 60715 inside a suitable electrical enclosure.
The device has a 150 V AC maximum continuous operating voltage, so it must not be assumed suitable for standard 230/400 V systems. The SPD voltage rating must be selected according to the actual voltage across the protected connections and the installation's earthing arrangement.
Both models are three-pole Type 2 surge protection devices with remote signalling. The 7P.23.8.150.1015 has a maximum continuous operating voltage of 150 V AC and a nominal discharge current of 15 kA, while the 7P.23.8.275.1020 is the higher-voltage variant rated at 275 V AC with a nominal discharge current of 20 kA.
The device has an IP20 ingress protection rating and should be installed inside an appropriately rated electrical enclosure. It is not suitable for unprotected outdoor mounting.
Finder 7P Series surge protection devices provide practical solutions for protecting electrical distribution and control systems against transient overvoltages. Combining Type 2 protection, three-pole varistor construction, 150 V AC maximum continuous operating voltage, 15 kA nominal discharge current, 40 kA maximum discharge current, replaceable modules and remote status signalling, the Finder 7P.23.8.150.1015 is suitable for electrical contractors, industrial panel builders, automation engineers and electrical maintenance professionals working with compatible low-voltage systems.