Finder 7P.21.8.130.1015 is a single-pole DIN rail-mounted Type 2 surge protection device for low-voltage AC and DC systems, featuring 130 V AC / 170 V DC maximum continuous operating voltage, 15 kA nominal discharge current, 40 kA maximum discharge current, 0.6 kV voltage protection level, replaceable varistor module and remote signalling contact.

SKU: 7P.21.8.130.1015Alt SKU: 7P2181301015MPN: 7P.21.8.130.1015
Price
List Price £91.71 ex VAT
Your Price (ex VAT) Save 25%
£68.78 25% OFF
You save £22.93 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £68.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£68.78

Why Choose the Finder 7P.21.8.130.1015 Type 2 Surge Protection Device?

The Finder 7P.21.8.130.1015 is a single-pole Type 2 surge protection device (SPD) designed to protect low-voltage AC and DC electrical installations against transient overvoltages. Part of the Finder Series 7P surge protection range, this DIN rail-mounted surge arrester uses metal oxide varistor technology to help protect industrial control equipment, power supplies and sensitive electronic systems from voltage surges caused by switching operations and induced lightning disturbances.

Designed for low-voltage electrical systems, the Finder 7P.21.8.130.1015 features a 130 V AC / 170 V DC maximum continuous operating voltage, a 15 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax). Its 0.6 kV voltage protection level (Up) helps limit transient voltages reaching connected electrical equipment when the SPD is correctly selected and installed.

The device combines a replaceable varistor protection cartridge, an integrated visual status indicator and a remote signalling changeover contact for monitoring the condition of the protective element. Its compact 17.5 mm DIN rail format, IP20 protection rating and wide operating temperature range make it a practical solution for industrial automation panels, electrical distribution boards and low-voltage power systems.

Key Advantages

  • Type 2 surge protection helps protect electrical equipment against induced lightning surges and switching transients.
  • Single-pole configuration suitable for designated low-voltage AC and DC installations.
  • 15 kA nominal discharge current provides robust surge-handling capability.
  • 40 kA maximum discharge current supports protection against higher-energy transient events.
  • 0.6 kV voltage protection level helps reduce the surge voltage reaching connected equipment.
  • 130 V AC / 170 V DC maximum continuous operating voltage for compatible electrical systems.
  • Replaceable varistor module simplifies maintenance without requiring replacement of the complete SPD base.
  • Visual protection status indicator allows straightforward inspection of the varistor condition.
  • Integrated remote signalling contact enables monitoring through a suitable external alarm or control system.
  • Compact 17.5 mm module width saves valuable space inside electrical panels.
  • 35 mm DIN rail mounting supports straightforward installation in standard electrical enclosures.
  • −40 to +80 °C operating temperature range supports demanding industrial environments.

Key Features

  • Finder Series 7P surge protection device.
  • 7P.21 single-pole Type 2 SPD configuration.
  • Metal oxide varistor (MOV) protection technology.
  • Suitable for compatible low-voltage AC and DC systems.
  • 130 V AC maximum continuous operating voltage (Uc).
  • 170 V DC maximum continuous operating voltage (Uc).
  • 15 kA nominal discharge current (In) using an 8/20 µs waveform.
  • 40 kA maximum discharge current (Imax) using an 8/20 µs waveform.
  • 0.6 kV voltage protection level (Up).
  • Replaceable varistor cartridge for convenient servicing.
  • Optical status indication showing whether the protection element is serviceable or requires replacement.
  • SPDT remote signalling contact for external monitoring.
  • Single-module DIN rail construction.
  • 35 mm DIN rail mounting in accordance with EN 60715.
  • 17.5 mm nominal module width.
  • IP20 ingress protection rating.
  • −40 to +80 °C ambient operating temperature range.
  • 50 kA short-circuit current rating (Isccr) under specified installation conditions.
  • IEC/EN 61643-11 surge protection device standard.
  • Suitable for installation at the LPZ 1 / LPZ 2 boundary within a coordinated lightning protection system.

Reliable Type 2 Surge Protection for Low-Voltage AC and DC Systems

Industrial automation equipment, instrumentation systems and electronic control circuits can be vulnerable to transient overvoltages generated by switching operations, inductive loads and lightning-related disturbances. Even short-duration voltage spikes can damage power supplies, programmable logic controllers and sensitive electronic components. A correctly specified Type 2 surge protection device helps limit these overvoltages and reduce the likelihood of equipment damage.

The Finder 7P.21.8.130.1015 is designed specifically for suitable lower-voltage AC and DC electrical systems. Its 130 V AC / 170 V DC maximum continuous operating voltage makes it appropriate for designated installations where a conventional SPD intended for 230 V AC mains circuits would not provide the required voltage characteristics.

The device uses metal oxide varistor technology, which responds to a transient overvoltage by becoming conductive and diverting surge current through the intended protective path. Its 15 kA nominal discharge current, 40 kA maximum discharge current and 0.6 kV voltage protection level provide defined surge protection characteristics for correctly designed low-voltage installations.

A key benefit of the Finder 7P.21.8.130.1015 is its replaceable varistor cartridge. The integrated visual indicator enables maintenance personnel to check the condition of the protection element, while the remote signalling changeover contact allows the SPD status to be incorporated into a suitable monitoring or alarm system. This is particularly useful in industrial installations where electrical equipment may operate continuously or be located in unattended cabinets.

The device mounts directly onto a standard 35 mm DIN rail and occupies approximately 17.5 mm of panel width. For effective protection, the SPD must be correctly coordinated with the electrical supply, earthing arrangement, upstream protective devices and any other surge protection stages. Installation should be undertaken by a qualified electrical professional in accordance with Finder's instructions and applicable electrical installation regulations.

Typical Applications

  • Low-voltage AC and DC electrical distribution systems.
  • Industrial automation and PLC control cabinets.
  • Electrical control panels and machine control systems.
  • Compatible 110 V AC control circuits.
  • Compatible 125 V DC electrical systems.
  • Industrial instrumentation and monitoring equipment.
  • Electronic control power supplies.
  • Motor control and manufacturing equipment control panels.
  • Industrial building services and electrical infrastructure.
  • Electrical installations exposed to induced lightning surges.
  • Systems requiring remote indication of surge protection status.
  • DIN rail-mounted surge protection in compact electrical enclosures.

Technical Specifications

Manufacturer Finder
Series 7P Surge Protection Devices
Model 7P.21.8.130.1015
Product type Type 2 surge protection device
SPD classification Type 2
Number of poles 1
Protection technology Metal oxide varistor (MOV)
Nominal AC system voltage 110 V AC
Nominal DC system voltage 125 V DC
Maximum continuous operating voltage (Uc), AC 130 V AC
Maximum continuous operating voltage (Uc), DC 170 V DC
Nominal discharge current (In) 15 kA (8/20 µs)
Maximum discharge current (Imax) 40 kA (8/20 µs)
Voltage protection level (Up) 0.6 kV
Short-circuit current rating (Isccr) 50 kA
Protection element Replaceable varistor cartridge
Local status indication Optical protection status indicator
Remote signalling Yes
Remote signalling contact type SPDT changeover contact
Mounting method DIN rail
DIN rail size 35 mm
DIN rail standard EN 60715
Module width 17.5 mm nominal
Installation space 1 modular spacing unit
Ingress protection IP20
Operating temperature −40 to +80 °C
Applicable standard IEC/EN 61643-11
Typical installation location LPZ 1 / LPZ 2 boundary or higher protection zone
EAN / GTIN 8012823378527

Frequently Asked Questions

What is the Finder 7P.21.8.130.1015 used for?

The Finder 7P.21.8.130.1015 is a single-pole Type 2 surge protection device designed to protect compatible low-voltage AC and DC electrical installations against transient overvoltages caused by electrical switching and induced lightning surges.

Is the Finder 7P.21.8.130.1015 a complete surge protection device?

Yes. The 7P.21.8.130.1015 is a complete DIN rail-mounted Type 2 surge protection device with a replaceable varistor cartridge, visual protection status indication and a remote signalling contact.

What is the maximum continuous operating voltage of this SPD?

The Finder 7P.21.8.130.1015 has a maximum continuous operating voltage (Uc) of 130 V AC or 170 V DC. The device must be selected according to the actual system voltage and electrical installation arrangement.

What is the nominal discharge current of the Finder 7P.21.8.130.1015?

The SPD has a 15 kA nominal discharge current (In), measured using the standard 8/20 µs surge current waveform.

What is the maximum discharge current of this surge protector?

The Finder 7P.21.8.130.1015 has a 40 kA maximum discharge current (Imax), measured using an 8/20 µs surge waveform.

What is the voltage protection level of the Finder 7P.21.8.130.1015?

The SPD has a specified 0.6 kV voltage protection level (Up). This indicates its surge voltage limitation performance under the relevant standard test conditions.

Does the Finder 7P.21.8.130.1015 have a remote signalling contact?

Yes. This model includes an SPDT changeover contact that can be connected to a suitable external monitoring or alarm system to indicate the status of the surge protection device.

Does this surge protection device have a visual status indicator?

Yes. The Finder 7P.21.8.130.1015 includes an optical status indicator that allows maintenance personnel to determine whether the varistor protection element remains serviceable or requires replacement.

Can the varistor module be replaced without replacing the complete SPD?

Yes. The replaceable varistor cartridge allows the protective module to be changed while retaining the existing SPD base, provided the base remains serviceable and the correct Finder replacement cartridge is used.

How is the Finder 7P.21.8.130.1015 installed?

The device is designed for mounting onto a standard 35 mm DIN rail in accordance with EN 60715. It occupies approximately 17.5 mm of DIN rail width and should be installed inside a suitable electrical enclosure.

Can the Finder 7P.21.8.130.1015 be used on a 230 V AC mains supply?

No. The Finder 7P.21.8.130.1015 has a maximum continuous AC operating voltage of 130 V AC and is not intended for direct use on a nominal 230 V AC mains supply. A correctly rated SPD must be selected for higher-voltage installations.

What is the operating temperature range of this surge protection device?

The Finder 7P.21.8.130.1015 is designed for ambient operating temperatures from −40 to +80 °C, making it suitable for a wide range of industrial electrical installations.

What is the difference between a Type 1 and Type 2 surge protection device?

A Type 1 SPD is tested for high-energy lightning impulse currents using a 10/350 µs waveform, while a Type 2 SPD is designed for transient overvoltages and is tested using an 8/20 µs surge waveform. The Finder 7P.21.8.130.1015 is a Type 2 device intended for appropriately coordinated surge protection installations.

Where is the Finder 7P.21.8.130.1015 typically installed?

The device is typically installed in industrial control cabinets, low-voltage AC and DC distribution boards, automation panels and electrical equipment enclosures requiring single-pole Type 2 surge protection and remote status monitoring.

Trusted by Electrical Installation and Industrial Automation Professionals Worldwide

Finder Series 7P surge protection devices provide practical, modular solutions for protecting electrical installations against transient overvoltages. Combining metal oxide varistor technology, replaceable protection cartridges, visual status indication and remote signalling capability, the Finder 7P.21.8.130.1015 offers a dependable surge protection solution for compatible low-voltage AC and DC industrial electrical systems.