Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 7P.21.8.130.0015 is a single-pole Type 2 surge protection device for compatible low-voltage AC and DC electrical systems. Featuring 130 V AC / 170 V DC maximum continuous operating voltage, 15 kA nominal discharge current, 40 kA maximum discharge current, metal oxide varistor technology, replaceable protective cartridge, visual status indication and compact 17.5 mm DIN rail mounting. This variant does not include remote signalling contacts.
£38.99
The Finder 7P.21.8.130.0015 is a compact, single-pole Type 2 surge protection device (SPD) designed to protect compatible low-voltage electrical installations against transient overvoltages caused by lightning-induced surges and electrical switching operations. Part of the Finder 7P Series, this DIN rail-mounted surge arrester combines metal oxide varistor technology, replaceable surge protection and visual status indication in a space-saving modular housing.
Designed for appropriately rated AC and DC circuits, the Finder 7P.21.8.130.0015 features a maximum continuous operating voltage (Uc) of 130 V AC or 170 V DC. It is particularly useful for electrical control systems, industrial automation equipment, specialist low-voltage distribution circuits and applications where a lower-voltage surge protection device is required.
With a nominal discharge current (In) of 15 kA and a maximum discharge current (Imax) of 40 kA, measured using the 8/20 µs surge current waveform, this Type 2 SPD provides substantial transient surge-handling capability. Its voltage-limiting varistor technology helps divert surge current through the intended protective path and reduce the risk of damage to connected electrical equipment.
The 7P.21.8.130.0015 is the version without remote signalling contacts, making it a straightforward solution where local visual protection status indication is sufficient. Its 17.5 mm DIN rail width and replaceable protective cartridge help simplify installation and ongoing maintenance in electrical distribution boards and industrial control panels.
Electrical installations can experience transient overvoltages caused by switching operations, lightning activity and disturbances travelling through connected power cables. Even short-duration voltage spikes can damage electronic equipment, industrial controllers, power supplies and other sensitive components. The Finder 7P.21.8.130.0015 is designed to help protect appropriately rated circuits against these electrical disturbances.
The device incorporates a metal oxide varistor, which provides voltage-dependent resistance. During normal operation, the varistor presents high resistance. When a transient overvoltage occurs, its resistance decreases rapidly, allowing surge current to be diverted through the intended protective path. This helps limit the voltage applied to downstream equipment.
The 130 V AC maximum continuous operating voltage makes this model suitable for specific lower-voltage AC systems, while its 170 V DC rating provides compatibility with certain DC applications. These values are important when selecting an SPD because the device must withstand the normal operating voltage of the protected circuit without unwanted operation.
Its 15 kA nominal discharge current and 40 kA maximum discharge current demonstrate the surge current capability of the protective element under the standard 8/20 µs test waveform. These ratings are useful when designing a coordinated surge protection system and assessing the expected transient exposure of the installation.
As a Type 2 surge protection device, the Finder 7P.21.8.130.0015 is intended primarily for protection against induced lightning surges and switching transients. It should not be treated as a direct substitute for a Type 1 lightning current arrester where the installation requires protection against partial direct lightning currents.
The replaceable varistor cartridge helps simplify maintenance, while the visual status indicator provides a convenient way to identify when the protective element requires attention. This version does not include remote signalling contacts, making it particularly appropriate for installations where periodic local inspection is sufficient.
The Finder 7P.21.8.130.0015 mounts onto a standard 35 mm DIN rail and occupies just 17.5 mm of rail width. This compact construction makes it suitable for electrical distribution boards, industrial control panels and other enclosures where space is limited.
As a single-pole SPD, the device must be connected according to the intended protective path and the electrical system's earthing arrangement. Correct installation is essential to ensure that surge current can be diverted effectively without compromising the safety or operation of the protected circuit.
The SPD should be installed with appropriate upstream protection and suitably sized conductors. Connection lengths should be kept as short and direct as practicable, in accordance with the manufacturer's instructions and applicable installation standards, to help minimise additional voltage drop during surge events.
The visual protection status indicator should be checked during routine electrical maintenance. If the protective element is no longer serviceable, the correct manufacturer-specified replacement cartridge should be fitted by a competent electrical professional after the installation has been safely isolated.
Because the 7P.21.8.130.0015 does not include remote signalling contacts, it cannot directly provide a remote healthy/fault contact signal. Where remote monitoring is required, the Finder 7P.21.8.130.1015 is the corresponding variant designed with remote signalling functionality.
The device has an IP20 protection rating and must be installed within a suitable electrical enclosure. Selection and installation should comply with applicable electrical regulations and relevant surge protection standards, including the appropriate requirements of BS 7671 and EN 61643-11.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Manufacturer part number | 7P.21.8.130.0015 |
| EAN / GTIN | 8012823400822 |
| Product type | Surge protection device / surge arrester |
| SPD classification | Type 2 / Class II |
| Number of poles | 1 |
| Protection technology | Metal oxide varistor |
| Nominal AC voltage (Un) | 110 V AC |
| Nominal DC voltage | 125 V DC |
| Maximum continuous operating voltage (Uc), AC | 130 V AC |
| Maximum continuous operating voltage (Uc), DC | 170 V DC |
| Nominal discharge current (In) | 15 kA |
| Maximum discharge current (Imax) | 40 kA |
| Discharge current waveform | 8/20 µs |
| Voltage protection level (Up) | Approximately 0.6–0.7 kV; confirm the applicable value against the current manufacturer datasheet |
| Short-circuit current rating (Isccr) | 50 kA, subject to specified installation conditions |
| Visual status indication | Yes |
| Remote signalling contact | No |
| Replaceable protective element | Varistor cartridge |
| Mounting | 35 mm DIN rail |
| Housing width | 17.5 mm |
| Modular size | 1 module |
| Ingress protection | IP20 |
| Operating temperature range | -40 °C to +80 °C |
| Application | Compatible low-voltage AC and DC electrical systems |
| Installation environment | Inside a suitable electrical distribution or control enclosure |
The Finder 7P.21.8.130.0015 is a single-pole Type 2 surge protection device designed to help protect compatible low-voltage AC and DC electrical systems against transient overvoltages caused by electrical switching events and lightning-induced surges.
It is a Type 2 / Class II surge protection device, intended primarily for protection against induced lightning surges and electrical switching transients. It is not a standalone Type 1 lightning current arrester.
The device has a maximum continuous operating voltage (Uc) of 130 V AC or 170 V DC. The SPD must be selected according to the maximum normal operating voltage of the protected electrical system.
No. The Finder 7P.21.8.130.0015 has a maximum continuous operating voltage of 130 V AC and is not suitable for direct connection across a conventional 230 V AC mains supply. A correctly rated SPD must be selected for 230 V installations.
The device has a specified 170 V DC maximum continuous operating voltage. Its suitability for a particular DC installation depends on the system configuration, earthing arrangement and manufacturer installation requirements.
The device has a nominal discharge current (In) of 15 kA, measured using the standard 8/20 µs surge current waveform.
The Finder 7P.21.8.130.0015 has a maximum discharge current (Imax) of 40 kA, measured using the 8/20 µs waveform.
No. The 7P.21.8.130.0015 does not include remote signalling contacts. It provides local visual protection status indication. For remote signalling functionality, the corresponding Finder 7P.21.8.130.1015 variant should be considered.
Yes. The device incorporates a replaceable varistor protection module, allowing the protective element to be replaced when required while retaining the compatible installed base.
The device mounts onto a standard 35 mm DIN rail and occupies 17.5 mm of rail width. Installation must be carried out by a competent electrical professional following Finder's instructions and applicable electrical regulations.
The device is specified for an operating temperature range of -40 °C to +80 °C, subject to correct installation within a suitable electrical enclosure.
The Finder 7P Series provides practical surge protection solutions for electrical distribution, industrial control and low-voltage installations. Combining Type 2 protection, 15 kA nominal discharge current, 40 kA maximum discharge current, replaceable varistor technology and compact DIN rail construction, the Finder 7P.21.8.130.0015 is a practical choice for installations requiring dependable local surge protection without remote signalling.
Manufacturer reference: Finder 7P Series Surge Protection Devices Technical Catalogue.