Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 7P.21.8.075.1015 is a single-pole Type 2 surge protection device for compatible low-voltage AC and DC electrical systems. Featuring 75 V AC / 100 V DC maximum continuous operating voltage, 15 kA nominal discharge current, 40 kA maximum discharge current, 0.4 kV voltage protection level, replaceable varistor module, visual status indication, remote signalling and compact 17.5 mm DIN rail mounting.
£68.36
The Finder 7P.21.8.075.1015 is a compact, single-pole Type 2 surge protection device (SPD) designed to protect low-voltage AC and DC electrical systems against transient overvoltages caused by electrical switching operations and lightning-induced surges. Part of the Finder 7P Series, this DIN rail-mounted surge arrester combines metal oxide varistor technology, replaceable protection and clear visual status indication in a space-saving modular housing.
Specifically developed for low-voltage AC and DC applications, the Finder 7P.21.8.075.1015 features a maximum continuous operating voltage of 75 V AC or 100 V DC. It is suitable for appropriately rated control circuits, industrial automation systems, electrical distribution equipment and other installations where conventional 230 V surge protection devices would not provide the required voltage-limiting characteristics.
With a nominal discharge current of 15 kA and a maximum discharge current of 40 kA, measured using the 8/20 µs waveform, the device provides substantial surge-handling capability for compatible low-voltage circuits. Its 0.4 kV voltage protection level helps reduce the transient voltage reaching downstream equipment when the SPD is correctly selected and installed.
The Finder 7P.21.8.075.1015 also incorporates a replaceable varistor module, visual protection status indication and a remote signalling contact arrangement. Its 17.5 mm DIN rail width makes it a practical solution for industrial panel builders, electrical contractors and maintenance engineers requiring reliable Type 2 surge protection without occupying excessive enclosure space.
Low-voltage electrical and electronic equipment can be vulnerable to transient overvoltages even when the normal operating voltage is relatively low. Switching operations, nearby lightning activity and disturbances in connected wiring can generate short-duration voltage spikes capable of damaging sensitive components. The Finder 7P.21.8.075.1015 is designed to help protect appropriately rated AC and DC circuits against these events.
The device uses metal oxide varistor technology to limit transient overvoltages. Under normal conditions, the varistor presents high electrical resistance. When the voltage rises above its protective operating threshold, the varistor rapidly becomes conductive, diverting surge current through the intended protective path and helping reduce the voltage experienced by downstream equipment.
With a maximum continuous operating voltage of 75 V AC or 100 V DC, this model is intended for lower-voltage applications rather than conventional 230 V mains circuits. Correct voltage selection is essential because the SPD must withstand the maximum normal operating voltage of the protected system while providing an appropriate voltage protection level.
The 15 kA nominal discharge current and 40 kA maximum discharge current demonstrate its ability to handle substantial transient surge currents using the standard 8/20 µs test waveform. The 0.4 kV voltage protection level provides a useful characteristic for coordinating the SPD with the impulse withstand capability of connected equipment.
The Finder 7P.21.8.075.1015 is classified as a Type 2 SPD, making it suitable for installation at appropriate points within an electrical surge protection system, commonly around the boundary between lightning protection zones LPZ 1 and LPZ 2 or higher. Where an installation is exposed to direct lightning current, additional appropriately rated Type 1 protection may be necessary.
Its replaceable varistor cartridge helps simplify servicing, while the visual protection status indicator provides a convenient way to check the condition of the protective element. The remote signalling arrangement can also be used with compatible monitoring equipment to provide information about SPD status.
The Finder 7P.21.8.075.1015 is designed for installation on a standard 35 mm DIN rail according to EN 60715. With a housing width of just 17.5 mm, it occupies a single modular position and is suitable for compact industrial control panels, electrical distribution boards and equipment cabinets.
As a single-pole SPD, it provides protection across the specified connection path. Depending on the application, the device may be used within appropriately designed low-voltage AC or DC protection arrangements. The correct connection method must be selected according to the electrical system, earthing arrangement and Finder's installation instructions.
The replaceable varistor module allows maintenance engineers to restore the protective element when required without necessarily replacing the complete DIN rail base. The visual Healthy/Replace indicator should be checked during routine electrical inspections and following known significant surge events.
The remote signalling contact arrangement can be incorporated into compatible control and monitoring circuits where remote indication of surge protection status is required. This is particularly useful in unattended electrical installations and industrial automation systems.
The device has an IP20 protection rating and must be installed within an appropriately rated enclosure. Installation and replacement should be performed by a competent electrical professional, with suitable upstream protection, conductor sizing, earthing and compliance with applicable electrical regulations.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Manufacturer part number | 7P.21.8.075.1015 |
| EAN / GTIN | 8012823378510 |
| Product type | Surge protection device / surge arrester |
| SPD classification | Type 2 |
| Number of poles | 1 |
| Protection technology | Metal oxide varistor |
| Application | Low-voltage AC and DC electrical systems |
| Nominal voltage (Un) | 60 V AC / 60 V DC |
| Maximum continuous operating voltage (Uc) | 75 V AC / 100 V DC |
| Nominal discharge current (In) | 15 kA |
| Maximum discharge current (Imax) | 40 kA |
| Discharge current test waveform | 8/20 µs |
| Voltage protection level (Up) | 0.4 kV |
| Response time (ta) | 25 ns |
| Protection status indication | Visual Healthy/Replace indicator |
| Remote signalling | Changeover contact arrangement |
| Replaceable protective element | Yes, varistor module |
| Mounting | 35 mm DIN rail, EN 60715 |
| Module width | 17.5 mm |
| Ingress protection | IP20 |
| Operating temperature range | -40 °C to +80 °C |
| Relevant product standard | EN 61643-11 |
| Installation location | Inside a suitable electrical distribution or control enclosure |
The Finder 7P.21.8.075.1015 is a single-pole Type 2 surge protection device designed to protect compatible low-voltage AC and DC electrical systems against transient overvoltages caused by switching events and lightning-induced surges.
The Finder 7P.21.8.075.1015 is a Type 2 surge protection device. It is designed for protection against induced lightning surges and switching transients rather than serving as a standalone Type 1 lightning current arrester.
Yes. The device is designed for compatible DC applications and low-voltage AC systems. Its maximum continuous operating voltage is 100 V DC or 75 V AC. The complete installation must be suitable for the system voltage and connection arrangement.
No. This model has a maximum continuous operating voltage of 75 V AC and is not suitable for direct connection across a conventional 230 V AC mains supply. A correctly rated Finder SPD should be selected for higher-voltage systems.
The device has a nominal discharge current (In) of 15 kA, measured using the standard 8/20 µs surge current waveform.
The device has a maximum discharge current (Imax) of 40 kA, measured using the 8/20 µs waveform.
The Finder 7P.21.8.075.1015 has a specified voltage protection level (Up) of 0.4 kV. This helps limit transient voltage exposure when the SPD is correctly selected, connected and coordinated with downstream equipment.
Yes. The device incorporates a replaceable varistor module, allowing the protective element to be replaced when necessary while retaining the compatible installed base.
Yes. The device supports remote status signalling through a changeover contact arrangement, allowing compatible monitoring equipment to indicate the condition of the surge protection device.
The device mounts onto a standard 35 mm DIN rail according to EN 60715 and occupies 17.5 mm of rail width. Installation must be carried out by a competent electrical professional following Finder's instructions and applicable electrical regulations.
The device is specified for an operating temperature range of -40 °C to +80 °C, subject to correct installation within a suitable electrical enclosure.
The Finder 7P Series provides practical surge protection solutions for industrial control systems, electrical distribution and low-voltage installations. Combining Type 2 protection, 15 kA nominal discharge current, 40 kA maximum discharge current, replaceable varistor technology and compact DIN rail mounting, the Finder 7P.21.8.075.1015 is a versatile choice for protecting compatible low-voltage AC and DC electrical equipment.
Manufacturer reference: Finder 7P Series Surge Protection Devices Technical Catalogue.