Finder 7P.13.9.500.0006 is a combined Type 1+2 surge protection device from the Finder 7P Series, designed to help protect compatible low-voltage electrical distribution installations against lightning-related and switching-induced transient overvoltages.
£176.63
The Finder 7P.13.9.500.0006 is a Type 1+2 surge protection device (SPD) from the Finder 7P Series, designed to protect low-voltage electrical installations against transient overvoltages associated with lightning activity and electrical switching events. It is intended for professional electrical distribution applications where coordinated surge protection helps safeguard connected equipment and reduce the risk of damage from high-energy electrical disturbances.
The 7P.13 product family is designed for applications requiring combined lightning-current and surge protection functions. By incorporating Type 1 and Type 2 protection characteristics, the device contributes to an installation's protection strategy against both high-energy lightning-related impulses and transient overvoltages that can affect sensitive electrical and electronic equipment.
The Finder 7P.13.9.500.0006 is intended for installation within an appropriately designed electrical distribution system. Its suitability depends on the supply configuration, earthing arrangement, prospective fault current, upstream protection and the surge protection coordination requirements of the installation.
Electrical installations can be exposed to short-duration overvoltage events caused by lightning activity, supply disturbances and the switching of inductive loads. Although these events may last only a fraction of a second, their peak voltage and current can be sufficient to damage insulation, disrupt electronic controls or cause premature failure of connected equipment.
The Finder 7P.13.9.500.0006 is designed to contribute to the management of these disturbances through combined Type 1+2 surge protection. Type 1 protection is associated with the discharge of lightning-related impulse currents, while Type 2 protection addresses transient surges within low-voltage electrical distribution systems. Combining these functions supports protection strategies where both categories of electrical disturbance must be considered.
Effective surge protection requires more than selecting an SPD by its classification alone. The maximum continuous operating voltage must be suitable for the electrical supply, the impulse and discharge current ratings must meet the installation requirements, and the voltage protection level must be coordinated with the withstand capability of connected equipment. Correct earthing, short connection lengths and suitable upstream protective devices are also essential to achieving the intended protection performance.
For the 7P.13.9.500.0006, the exact electrical ratings and permitted network configurations should be confirmed using Finder's model-specific technical information before specification or installation. This ensures that the device is selected for the intended distribution system rather than relying solely on general characteristics of the 7P Series.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Model | 7P.13.9.500.0006 |
| Manufacturer part number | 7P.13.9.500.0006 |
| Product category | Surge protection devices |
| Product family | 7P.13 |
| Protection classification | Type 1+2 |
| Primary function | Lightning-current and transient overvoltage protection |
| Electrical application | Low-voltage AC distribution systems |
| Installation | Electrical distribution enclosure |
| Relevant SPD standard family | IEC/EN 61643-11 |
| Selection requirements | Verify maximum continuous operating voltage, lightning impulse current, discharge current, voltage protection level and system compatibility against the manufacturer's technical documentation. |
The Finder 7P.13.9.500.0006 is a surge protection device intended to help protect low-voltage electrical installations against transient overvoltages associated with lightning and electrical switching events.
Type 1+2 indicates a surge protection device combining lightning-current protection characteristics associated with Type 1 SPDs and transient surge protection characteristics associated with Type 2 SPDs.
The Finder 7P Series is intended for professional electrical surge protection applications, including industrial distribution systems. The suitability of this specific model must be checked against the supply voltage, earthing arrangement, fault conditions and required surge protection ratings.
A Type 1+2 SPD can form part of an installation's protection against lightning-related electrical surges, but it cannot prevent a lightning strike or guarantee protection against every possible event. Effective protection depends on the complete lightning protection, earthing and electrical installation design.
Type 1 SPDs are tested for high-energy lightning impulse currents using a 10/350 µs waveform, while Type 2 SPDs are tested for transient surge currents using an 8/20 µs waveform. A combined Type 1+2 device provides both categories of protection within its specified ratings.
The maximum continuous operating voltage (Uc) is the highest voltage that may be continuously applied to an SPD under its specified operating conditions. The Uc rating must be appropriate for the electrical network in which the device is installed.
The voltage protection level (Up) describes the voltage-limiting performance of an SPD under defined test conditions. A suitable Up rating helps protect connected equipment, but the effective protection level also depends on installation wiring and coordination.
Replacement is appropriate only when the electrical ratings, protection configuration, installation requirements and manufacturer-approved compatibility match the existing application. Different Finder 7P models should not be treated as interchangeable solely because they belong to the same series.
No. A surge protection device is intended to manage transient overvoltages. It does not replace the normal overcurrent and short-circuit protection provided by appropriately selected circuit breakers or fuses.
Installation should be carried out by a qualified electrical professional following the manufacturer's instructions and applicable electrical installation regulations. Correct upstream protection, conductor routing and earthing are essential.
Check the electrical network configuration, maximum continuous operating voltage, lightning impulse current, nominal discharge current, voltage protection level, prospective fault current, upstream protective device requirements and compatibility with the intended installation.
Finder 7P Series surge protection devices support reliable electrical distribution design by helping manage lightning-related and switching-induced transient overvoltages. The Finder 7P.13.9.500.0006 offers a combined Type 1+2 protection approach for appropriately specified industrial and commercial electrical installations.