Finder 7P.13.9.500.0006 - 7P Series Surge Protection Devices

Finder 7P.13.9.500.0006 – 7P Series Surge Protection Devices

Finder 7P.13.9.500.0006 is a combined Type 1+2 surge protection device from the Finder 7P Series, designed to help protect compatible low-voltage electrical distribution installations against lightning-related and switching-induced transient overvoltages.

SKU: 7P.13.9.500.0006Alt SKU: 7P1395000006MPN: 7P.13.9.500.0006
Price
List Price £235.50 ex VAT
Your Price (ex VAT) Save 25%
£176.63 25% OFF
You save £58.88 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £176.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£176.63

Why Choose the Finder 7P.13.9.500.0006 Surge Protection Device?

The Finder 7P.13.9.500.0006 is a Type 1+2 surge protection device (SPD) from the Finder 7P Series, designed to protect low-voltage electrical installations against transient overvoltages associated with lightning activity and electrical switching events. It is intended for professional electrical distribution applications where coordinated surge protection helps safeguard connected equipment and reduce the risk of damage from high-energy electrical disturbances.

The 7P.13 product family is designed for applications requiring combined lightning-current and surge protection functions. By incorporating Type 1 and Type 2 protection characteristics, the device contributes to an installation's protection strategy against both high-energy lightning-related impulses and transient overvoltages that can affect sensitive electrical and electronic equipment.

The Finder 7P.13.9.500.0006 is intended for installation within an appropriately designed electrical distribution system. Its suitability depends on the supply configuration, earthing arrangement, prospective fault current, upstream protection and the surge protection coordination requirements of the installation.

Key Advantages

  • Combined Type 1+2 surge protection supports a coordinated approach to lightning-current and transient overvoltage protection.
  • Designed for low-voltage electrical distribution in industrial and commercial installations.
  • High-energy surge protection capability helps manage electrical disturbances associated with lightning events.
  • Protection against switching transients helps reduce overvoltage stress on connected equipment.
  • Finder 7P Series design supports integration into professional electrical protection systems.
  • Distribution-board application enables protection close to important electrical supply points.
  • Supports equipment reliability by helping limit potentially damaging transient overvoltages.
  • Suitable for coordinated SPD installations where multiple protection stages are required.
  • Professional electrical installation design supports use alongside appropriate circuit protection and earthing systems.
  • Reduced equipment exposure to surges can help minimise disruption caused by transient electrical disturbances.

Key Features

  • Finder 7P Series surge protection device.
  • 7P.13 product family.
  • Combined Type 1 and Type 2 surge protection.
  • Designed for transient overvoltage protection in electrical distribution installations.
  • Lightning-current protection function associated with Type 1 SPDs.
  • Surge-limiting protection function associated with Type 2 SPDs.
  • Intended for appropriately configured AC electrical systems.
  • Suitable for coordinated surge protection schemes.
  • Designed for installation by qualified electrical professionals.
  • Compatible system selection based on manufacturer-approved electrical and protection characteristics.

Reliable Protection Against Lightning and Switching Surges

Electrical installations can be exposed to short-duration overvoltage events caused by lightning activity, supply disturbances and the switching of inductive loads. Although these events may last only a fraction of a second, their peak voltage and current can be sufficient to damage insulation, disrupt electronic controls or cause premature failure of connected equipment.

The Finder 7P.13.9.500.0006 is designed to contribute to the management of these disturbances through combined Type 1+2 surge protection. Type 1 protection is associated with the discharge of lightning-related impulse currents, while Type 2 protection addresses transient surges within low-voltage electrical distribution systems. Combining these functions supports protection strategies where both categories of electrical disturbance must be considered.

Effective surge protection requires more than selecting an SPD by its classification alone. The maximum continuous operating voltage must be suitable for the electrical supply, the impulse and discharge current ratings must meet the installation requirements, and the voltage protection level must be coordinated with the withstand capability of connected equipment. Correct earthing, short connection lengths and suitable upstream protective devices are also essential to achieving the intended protection performance.

For the 7P.13.9.500.0006, the exact electrical ratings and permitted network configurations should be confirmed using Finder's model-specific technical information before specification or installation. This ensures that the device is selected for the intended distribution system rather than relying solely on general characteristics of the 7P Series.

Typical Applications

  • Industrial electrical distribution boards.
  • Commercial building power distribution systems.
  • Main and sub-distribution surge protection installations.
  • Electrical infrastructure exposed to lightning-related disturbances.
  • Industrial automation and control equipment supply protection.
  • Manufacturing and process control electrical systems.
  • Building services electrical distribution.
  • Power supplies serving sensitive electronic equipment.
  • Coordinated Type 1 and Type 2 surge protection arrangements.
  • Electrical installation upgrades requiring improved transient overvoltage protection.

Technical Specifications

Manufacturer Finder
Series 7P Series
Model 7P.13.9.500.0006
Manufacturer part number 7P.13.9.500.0006
Product category Surge protection devices
Product family 7P.13
Protection classification Type 1+2
Primary function Lightning-current and transient overvoltage protection
Electrical application Low-voltage AC distribution systems
Installation Electrical distribution enclosure
Relevant SPD standard family IEC/EN 61643-11
Selection requirements Verify maximum continuous operating voltage, lightning impulse current, discharge current, voltage protection level and system compatibility against the manufacturer's technical documentation.

Frequently Asked Questions

What is the Finder 7P.13.9.500.0006 used for?

The Finder 7P.13.9.500.0006 is a surge protection device intended to help protect low-voltage electrical installations against transient overvoltages associated with lightning and electrical switching events.

What does Type 1+2 surge protection mean?

Type 1+2 indicates a surge protection device combining lightning-current protection characteristics associated with Type 1 SPDs and transient surge protection characteristics associated with Type 2 SPDs.

Is the Finder 7P.13.9.500.0006 suitable for industrial installations?

The Finder 7P Series is intended for professional electrical surge protection applications, including industrial distribution systems. The suitability of this specific model must be checked against the supply voltage, earthing arrangement, fault conditions and required surge protection ratings.

Can this SPD protect equipment against direct lightning strikes?

A Type 1+2 SPD can form part of an installation's protection against lightning-related electrical surges, but it cannot prevent a lightning strike or guarantee protection against every possible event. Effective protection depends on the complete lightning protection, earthing and electrical installation design.

What is the difference between Type 1 and Type 2 surge protection?

Type 1 SPDs are tested for high-energy lightning impulse currents using a 10/350 µs waveform, while Type 2 SPDs are tested for transient surge currents using an 8/20 µs waveform. A combined Type 1+2 device provides both categories of protection within its specified ratings.

What does maximum continuous operating voltage mean?

The maximum continuous operating voltage (Uc) is the highest voltage that may be continuously applied to an SPD under its specified operating conditions. The Uc rating must be appropriate for the electrical network in which the device is installed.

What is the voltage protection level of an SPD?

The voltage protection level (Up) describes the voltage-limiting performance of an SPD under defined test conditions. A suitable Up rating helps protect connected equipment, but the effective protection level also depends on installation wiring and coordination.

Can the Finder 7P.13.9.500.0006 replace another Finder 7P surge protector?

Replacement is appropriate only when the electrical ratings, protection configuration, installation requirements and manufacturer-approved compatibility match the existing application. Different Finder 7P models should not be treated as interchangeable solely because they belong to the same series.

Does a surge protection device replace a circuit breaker or fuse?

No. A surge protection device is intended to manage transient overvoltages. It does not replace the normal overcurrent and short-circuit protection provided by appropriately selected circuit breakers or fuses.

Who should install the Finder 7P.13.9.500.0006?

Installation should be carried out by a qualified electrical professional following the manufacturer's instructions and applicable electrical installation regulations. Correct upstream protection, conductor routing and earthing are essential.

What should be checked before selecting this surge protector?

Check the electrical network configuration, maximum continuous operating voltage, lightning impulse current, nominal discharge current, voltage protection level, prospective fault current, upstream protective device requirements and compatibility with the intended installation.

Designed for Professional Electrical Protection Systems

Finder 7P Series surge protection devices support reliable electrical distribution design by helping manage lightning-related and switching-induced transient overvoltages. The Finder 7P.13.9.500.0006 offers a combined Type 1+2 protection approach for appropriately specified industrial and commercial electrical installations.