Finder 7P.05.8.275.1012 is a Type 1+2 three-phase TN-S surge protection device with four varistor and spark-gap protection elements, 275 V AC maximum continuous operating voltage, 30 kA nominal discharge current, 60 kA maximum discharge current, replaceable modules and remote status signalling.
£499.22
The Finder 7P.05.8.275.1012 is a high-performance Type 1+2 three-phase surge protection device (SPD) designed to protect low-voltage electrical installations against lightning-induced surges and switching overvoltages. Part of the Finder 7P Series, this surge arrester features a 3+N configuration with four combined varistor and gas discharge tube (GDT) protection elements, specifically designed for compatible TN-S three-phase electrical systems.
With a 275 V AC maximum continuous operating voltage (Uc), a 30 kA nominal discharge current (In) and a 60 kA maximum discharge current (Imax), the Finder 7P.05.8.275.1012 provides robust protection against transient overvoltages. Its combined Type 1 and Type 2 classification enables protection against high-energy lightning impulse currents as well as switching-related electrical surges.
The device incorporates replaceable surge protection modules, visual status indication and an integrated remote signalling changeover contact for monitoring protection status. Featuring IP20 protection, a compact modular housing and 35 mm DIN rail mounting, it is suitable for industrial distribution boards, commercial switchgear and electrical installations requiring coordinated surge protection.
The Finder 7P.05.8.275.1012 combines Type 1 lightning current protection with Type 2 transient overvoltage limitation in a single modular device. This enables the SPD to form part of a coordinated protection strategy for electrical installations exposed to lightning-related disturbances and switching surges.
Its four combined varistor and encapsulated spark-gap protection elements provide surge protection between the three phase conductors and protective earth, as well as between neutral and protective earth. The combined technology supports high discharge current capability, low residual voltage and a leakage-current-free design during normal operation.
The device is intended for compatible TN-S earthing arrangements and may be installed at the boundary between lightning protection zones LPZ 0 and LPZ 1, or at other locations determined by the installation's surge protection design. Correct coordination with upstream protection and downstream equipment is essential for effective operation.
The Finder 7P.05.8.275.1012 incorporates replaceable surge protection modules, allowing individual protective elements to be serviced when replacement is required. This modular construction helps simplify maintenance compared with arrangements that require complete device replacement.
Each protection module includes visual status indication, enabling maintenance personnel to identify whether the protective element remains operational or requires replacement. The integrated SPDT remote signalling contact allows the SPD status to be incorporated into compatible monitoring systems, providing additional visibility for maintenance and electrical infrastructure management.
For installation, the unit features 35 mm DIN rail mounting and screw terminals. Engineers should verify the required backup fuse arrangement, earthing configuration, conductor routing and protective device coordination using the manufacturer's installation instructions and applicable electrical standards.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Product family | 7P.05 |
| Model | 7P.05.8.275.1012 |
| Product type | Combined lightning and surge protection device |
| SPD classification | Type 1+2 |
| Protection configuration | 3+N, four protection paths |
| Compatible earthing arrangement | TN-S |
| Nominal voltage (Un) | 230 V AC phase-to-neutral |
| Three-phase system | 230/400 V AC |
| Maximum continuous operating voltage (Uc) | 275 V AC |
| Nominal discharge current (In), 8/20 µs | 30 kA |
| Maximum discharge current (Imax), 8/20 µs | 60 kA |
| Voltage protection level (Up) | 1.5 kV |
| Voltage protection level, L–N | 1.5 kV |
| Voltage protection level, N–PE | 1.5 kV |
| Short-circuit current rating (Isccr) | 50 kA |
| Protection technology | Combined varistor and gas discharge tube (GDT) |
| Number of combined protection elements | 4 |
| Leakage current | Leakage-current-free design |
| Protection module replacement | Replaceable modules |
| Local status indication | Visual protection status indicator |
| Remote signalling | Integrated SPDT changeover contact |
| Operating temperature | −40 to +80 °C |
| Ingress protection | IP20 |
| Mounting | 35 mm DIN rail |
| Mounting standard | EN 60715 |
| Connection type | Screw terminals |
| Maximum rigid conductor cross-section | 35 mm² |
| Maximum flexible conductor cross-section | 25 mm² |
| Housing width | Approximately 72 mm |
| Housing height | Approximately 87.6 mm |
| Housing depth | Approximately 81.7 mm |
| Relevant standard | EN/IEC 61643-11 |
| EAN | 8012823437927 |
| Manufacturer part number | 7P.05.8.275.1012 |
The Finder 7P.05.8.275.1012 is a Type 1+2 three-phase surge protection device designed to protect compatible TN-S electrical installations against lightning impulse currents and transient overvoltages caused by electrical switching.
The device has a 30 kA nominal discharge current (In) and a 60 kA maximum discharge current (Imax), both specified for an 8/20 µs surge waveform. It also provides a 1.5 kV voltage protection level.
The Finder 7P.05.8.275.1012 is designed for compatible three-phase TN-S systems, using four protection paths between L1–PE, L2–PE, L3–PE and N–PE.
Yes. The device includes replaceable surge protection modules, visual protection status indication and an integrated SPDT remote signalling contact for monitoring the condition of the surge protection elements.
The surge protection device mounts onto a standard 35 mm DIN rail according to EN 60715 and uses screw terminals for electrical connections. Installation must follow Finder's wiring instructions, including the specified earthing arrangement, conductor requirements and upstream protective device coordination.
Finder 7P Series surge protection devices provide dependable protection against lightning-related and switching-induced transient overvoltages in low-voltage electrical installations. The 7P.05.8.275.1012 combines Type 1+2 protection, 30 kA nominal discharge current, 60 kA maximum discharge current, 1.5 kV voltage protection level, replaceable modules and remote status signalling for compatible three-phase TN-S distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.